Explanation
Platform LIC detected an errorResponse
A virtual adapter configuration error occurred.
A partition tried to use a virtual adapter which is associated with another virtual adapter in a remote partition and virtual slot. However, either no virtual adapter is configured there, or the wrong kind of virtual adapter is configured there.
The partition ID of the virtual adapter with the problem is in word 4 of the SRC (in hexadecimal format). The virtual slot number of the adapter with the incorrect configuration is the last four digits of word 6 of the SRC (in hexadecimal format).
Use the Hardware Management Console (HMC) to verify or reconfigure the incorrect virtual adapter configuration. If the configuration is correct, continue with the next failing item in the list.