Explanation
Platform LIC detected an error
Response
Abnormal or unexpected HSL OptiConnect disconnection from a
remote system or partition.
The local system or partition disconnected from a remote
system or partition due to an unexpected event or failure.
All of the HSL OptiConnect connections on this loop will be
in a failed state. Licensed Internal Code will attempt to
recover from the error. Intervention at the local or remote
system or partition might be required. Possible causes are:
- Time out of a critical message
- Licensed Internal Code code / table problem
- Network deadlock detected
The problem may be with:
- The local system or partition
- The remote system or partition
On the local system or partition, examine the SAL or
serviceable event view. Look for RIO or HSL failures on the
same
RIO or HSL loop or with the RIO or HSL controller that
occurred at approximately the same time as this error.
Examine the remote system or partition for problems. On the
remote system or partition, examine the SAL or serviceable
event view. Look for problems on the same RIO or HSL loop
or
with
the RIO or HSL controller that occurred at
approximately the same time as this error.
Correct any problems you find with the remote and local
systems or partitions that happened at approximately the
same time and involve HSL Opticonnect or RIO or HSL loop
components.
If there are no problems with the remote system or partition
and there are no problems with the local system or partition
then collect all the Product Activity Log information for
this failure on all systems or partitions. Be sure to record
all words in the SRCs. Contact your next level of support.
Problem determination
No action is required.