B70069C9 B70069C9

Explanation

Platform LIC detected an error

Response

Abnormal or unexpected HSL OptiConnect disconnection from a remote system or partition. The local system or partition disconnected from a remote system or partition due to an failure in a Licensed Internal Code virtualized bus unit. Licensed Internal Code will attempt to recover from the error. Possible causes are:
  • Licensed Internal Code problem where the local bus unit is offline.
  • Licensed Internal Code problem where the remote bus unit is offline.
On the local system or partition, examine the SAL or the serviceable event view. Look for HSL Opticonnect failures that occurred at approximately the same time as this error. Examine the remote system or partition for problems. On the remote system or partition, examine the SAL or the serviceable event view. Look for HSL Opticonnect problems that occurred at approximately the same time as this error. Collect all the Product Activity Log information for this failure on all systems and partitions on this RIO or HSL loop. Be sure to record all words in the SRCs. Contact your next level of support.

Problem determination

No action is required.

Failing Item