(B2xxxxxx) Logical partition reference codes

For use by service providers.

When the server posts these SRCs, you can find them in the Serviceable Event View or the view that you use to see informational logs (such as the Product Activity Log or ASM).

Characters 3 and 4 of word 1 are the partition ID of the logical partition with the problem.

If you do not find an SRC in the table that follows, contact your next level of support for assistance.
Notes:
  1. The SRCs on this page are from the Power Systems hardware documentation, and the Descriptions apply to a single CEC enclosure or I/O enclosure. The Action and Failing Item fields are modified as appropriate for DS8000® architecture and repair methods.
  2. SRCs missing from the following tables might be found on the Power Systems online documentation. You can use the SRC description as is to define the problem. Do not use the Action and Failing Item without contacting the next level of support first.
  3. To display the Power Systems hardware online documentation, go to the Web site http://www-01.ibm.com/support/knowledgecenter/.
    • In the IBM Systems Hardware Information right content pane, click POWER6 reference codes listing.
Table 1. (B2xxxxxx) Logical partition reference codes
SRC Description/Action Failing Item
B2xx1150 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC.

This is a partitioning configuration problem. The LPARCFG Symbolic FRU will help correct the problem.

If the problem persists, call your next level of support.

LPARCFG
B2xx1225 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC.

The partition attempted to IPL prior to the platform fully initializing. Retry the partition IPL after the platform IPL has fully completed and the platform is not in power off state. If that IPL fails, call your next level of support.

SVCDOCS
B2xx1230 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC.

This is a partitioning configuration problem. The partition is lacking the necessary resources to IPL.

This error might occur when you shut down a partition that is set to automatically IPL and then turn the managed system off and back on. When the partition automatically IPLs, it uses the resources specified in PHYP NVRAM, and this error occurs when the server does not find the exact resources specified in NVRAM. The solution is to activate the partition by using the partition profile on the HMC. The HMC applies the values in the profile to NVRAM. When the partition IPLs, it uses the resources specified in the profile.

LPARCFG

LICCODE

B2xx1260 A problem occurred during the IPL of a partition.

The partition identified in the xx field of the B2xx SRC could not IPL at the Timed Power On setting because the IPL setting of the partition was not set to Normal.

SVCDOCS
B2xx1265 A problem occurred during the IPL of a partition.

The partition identified in the xx field of the B2xx SRC could not IPL.

An operating system MSD IPL was attempted with the IPL side on D-mode. This is not a valid operating system IPL scenario, and the IPL will be halted. This SRC is usually seen when a D-mode SLIC install fails and attempts an MSD.

SVCDOCS
B2xx1266 A problem occurred during the IPL of a partition.

The partition identified in the xx field of the B2xx SRC could not IPL.

You are attempting to IPL an operating system that is not supported.

SVCDOCS
B2xx1310 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. No alternate (D-mode) IPL IOP was selected. The IPL will attempt to continue, but there might not be enough information to find the correct D-mode load source.

Have the customer configure an alternate IPL IOP for the partition. Then retry the partition IPL.

SVCDOCS
B2xx1320 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. No default load source IOP was selected for an A/B-mode IPL. The IPL will attempt to continue, but there might not be enough information to find the correct load source.

Have the customer configure a load source IOP for the partition. Then retry the partition IPL.

SVCDOCS
B2xx1321 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. The IOA for the load source device needed an IOP, and none was detected. Check your LPAR config and make sure the correct slot is specified for the IPL load source. Then retry the partition IPL.

SVCDOCS
B2xx1322 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. During the partition IPL, code tried to determine if the device in a slot was an I/O Processor or an I/O Adapter. That check failed. Check your LPAR configuration and make sure that the correct slot is specified for the IPL load source. Then retry the partition IPL. If this does not resolve the problem, perform LICIP01.

SVCDOCS
B2xx2250 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. A slot that was needed for the partition was unavailable. See the Symbolic FRU SLOTUSE for more information on the cause of this error.

SLOTUSE
B2xx2300 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. A slot that was needed for the partition was unavailable. See the Symbolic FRU SLOTUSE for more information on the cause of this error.

SLOTUSE
B2xx2310, B2xx2320 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. The platform LIC for this partition attempted an operation. There was a failure. Contact your next level of support.

NEXTLVL
B2xx2425 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. The platform LIC for this partition attempted an operation. There was a failure. Contact your next level of support.

NEXTLVL
B2xx2426 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. The platform LIC for this partition attempted an operation. There was a failure. Contact your next level of support.

NEXTLVL
B2xx2475 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. A slot that was needed for the partition was either empty or the device in the slot has failed. See the Symbolic FRU for more information on the cause of this error.

If you have a RAID enablement card (CCIN 5709) on your system, it will disable an embedded SCSI adapter. If that embedded slot is called out in the error, you can safely ignore this error.

SLOTUSE
B2xx2485 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. The platform LIC for this partition attempted an operation. There was a failure. Contact your next level of support.

NEXTLVL
B2xx3110 A problem occurred during the IPL of a partition.

The search for a valid load source device was exhausted. The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. Perform LICIP01.

SVCDOCS
B2xx3113 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. A problem occurred on the path to the load source for the partition.

If present, look in the Serviceable Event View for a B7xx xxxx during the partition's IPL. Correct that error and retry the partition IPL.

SVCDOCS
B2xx3114 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC.

The B2xxxxxx SRC Format is Word 1: B2xx3114, Word 3: Bus, Word 4: Board, Word 5: Card.

NEXTLVL
B2xx3120 System log entry only, no service action required

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. Retry count exceeded. This is logged for each unsuccessful attempt to IPL with a loadsource candidate. If the IPL fails, look for other serviceable errors.

B2xx3123 System log entry only, no service action required
B2xx3125 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC.

This is a platform LIC main store utilization problem. The platform LIC could not obtain a segment of main storage within the platform's main store to use for managing the creation of a partition.

LICCODE
B2xx3128 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. An unexpected failure return code was returned when attempting to query the IOA slots that are assigned to an IOP.

Look for B700 69xx errors in the Serviceable Event View and work those errors.

NEXTLVL
B2xx3130 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. If word 3 is zero, and then this SRC is informational and can be ignored.

Otherwise there is a problem in the platform LIC. A nonzero bus number has no associated bus object.

Look for B700 69xx errors in the Serviceable Event View and work those errors.

If there are no serviceable B700 69xx errors, or if correcting the errors did not correct this problem, contact your next level of support.

NEXTLVL
B2xx3135 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. An unknown bus type was detected.

NEXTLVL
B2xx3140 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. The load source IOP is not owned by the partition. This is a configuration problem in the partition. Have the customer re-configure the partition to have the intended load source IOP.

If there is not a configuration problem then contact your next level of support.

SVCDOCS
B2xx3200 System log entry only, no service action required

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC.

Look for a SRC in the Serviceable Event View logged at the time the partition was performing an IPL.

This error indicates a failure during a search for the load source. There might be a number of these failures prior to finding a good load source. This is normal. If a B2xx3110 error is logged, a B2xx3200 might be posted to the control panel. Work the B2xx3110 error in the Serviceable Event View. If the system IPL hangs at B2xx3200 and you cannot check the SRC history, perform the actions indicated for the B2xx3110 SRC.

B2xx5106 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. There is not enough space to contain the partition main storage dump.

Contact your next level of support.

NEXTLVL
B2xx5109 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. There was a partition main storage dump problem. Contact your next level of support.

NEXTLVL
B2xx5114 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. There is not enough space to contain the partition main storage dump. Contact your next level of support.

NEXTLVL
B2xx5115 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. There was an error reading the partition's main storage dump from the partition's load source into main storage.

NEXTLVL
B2xx5117 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. A partition main storage dump has occurred but cannot be written to the load source device because a valid dump already exists.

Use the Main Storage Dump Manager to rename or copy the current main storage dump.

SVCDOCS
B2xx5121 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. There was an error writing the partition's main storage dump to the partition's load source.

NEXTLVL
B2xx5135, B2xx5137, B2xx5145 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. There was an error writing the partition's main storage dump to the partition's load source.

NEXTLVL
B2xx5148 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. An error occurred while doing a main storage dump that would have caused another main storage dump.

Contact your next level of support.

NEXTLVL
B2xx6006 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. A platform LIC error occurred when the partition's memory initialized. The IPL will not continue.

Contact your next level of support.

NEXTLVL
B2xx6012 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. The partition's LID failed to completely load into the partition's mainstore area.

Contact your next level of support.

NEXTLVL
B2xx6015 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC.

The load source media is corrupted or not valid.

LSERROR
B2xx6025 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC.

This is a problem with the load source media being corrupt or not valid.

LSERROR
B2xx6027 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC.

A failure occurred when allocating memory for an internal object used for LID load operations. Ensure the partition was allocated enough main storage, verify that no memory leaks are present, and then retry the operation.

NEXTLVL
B2xx6110 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. Error on load source device.

LSERROR
B2xx7200 System log entry only, no service action required

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. An error condition was encountered when communicating with the load source I/O Processor for the partition identified in the xx field of the B2xx SRC.

This informational error indicates a failure resetting the I/O Processor in the preceding B2xx3200 error. This is normal. If there is a hardware failure there will be a different serviceable event. If the system IPL hangs at B2xx7200 and you cannot check the SRC history, perform the actions indicated for the B2xx3110 SRC.

B2xx8080 System log entry only, no service action required
B2xx8081 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. An internal LIC timeout has occurred. The partition might continue to IPL but it might experience problems while running.

LICCODE
B2xx8105 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. There was a failure loading the VPD areas of the partition. The load source media has been corrupted or is unsupported on this system.

LSERROR
B2xx8107 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. There was a problem getting a segment of main storage in the platform's main store.

LICCODE
B2xx8109 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. A failure occurred. The IPL is terminated. Ensure that there is enough memory to IPL the partition.

LICCODE
B2xx8112 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. A failure occurred. The IPL is terminated.

LICCODE
B2xx8113 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. A problem occurred on the path to the load source for the partition.

There was an error mapping memory for the partition's IPL. Call your next level of support.

LICCODE
B2xx8114 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. A problem occurred on the path to the load source for the partition.

There was a failure verifying VPD for the partition's resources during IPL. Call your next level of support.

LICCODE
B2xx8115 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. There was a low level partition to partition communication failure.

LICCODE
B2xx813A A problem occurred during the IPL of a partition.

Communication to the service processor has failed. The IPL will continue and the partition will likely be usable, but the console attached to the serial port might not be usable. A system power off followed by a reset/reload of the FSP might clear up the problem.

SVCDOCS
B2xxA100 to B2xxA101 A problem occurred after a partition ended abnormally.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. This partition could not stay running and shut itself down.

Work any error logs in the Serviceable Event View. If there are no errors, contact your next level of support.

SVCDOCS
B2xxB07B System log entry only, no service action required
B2xxB215 A problem occurred after a partition ended abnormally.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. There was a communications problem between this partition's service processor and the platform's service processor.

The platform will need to be reIPLed before that partition can be used. Call your next level of support.

NEXTLVL
B2xxD150 A problem occurred after a partition ended abnormally.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. There was a communications problem between this partition and code that handles resource allocation. Call your next level of support.

LICCODE
B2xxE0AA A problem occurred during the IPL of a partition.

Communication to the service processor has failed. The IPL will continue and the partition will likely be usable, but the console attached to the serial port might not be usable. A system power off followed by a reset/reload of the FSP might clear up the problem.

SVCDOCS
B2xxF001 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. An operation has timed out.

Ignore this error if there are other serviceable errors. Work those error logs for this partition and for the platform from the Serviceable Event View. If there are no errors, contact your next level of support.

SVCDOCS
B2xxF003 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. Partition processors did not start LIC within the timeout window.

Capture a Partition Dump and call your next level of support.

NEXTLVL
B2xxF004 to B2xxF005 A problem occurred during a power off of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. This partition had a communications problem.

Capture a Partition Dump and call your next level of support.

NEXTLVL
B2xxF006 A problem occurred during the IPL of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. The code load operation for the partition's IPL timed out.

Work any error logs for this partition in the Serviceable Event View. If there are no errors, contact your next level of support.

SVCDOCS
B2xxF007 A problem occurred during a power off of a partition.

The partition ID is characters 3 and 4 of the B2xx reference code in word 1 of the SRC. A problem occurred on the path to the load source for the partition.

A timeout occurred during the process of trying to stop a partition from running. Contact your next level of support.

LICCODE