The C2xxxxxx progress codes indicate the progress of a partition IPL that is controlled by the virtual service processor. The virtual service processor can start a variety of operating systems, and some codes below do not apply to the IPL path of a particular operating system. The virtual service processor progress codes end after the environment setup completes and the specific operating system code continues the IPL.

Table 1. (C2xxxxxx) Virtual service processor progress codes
Progress Code Description/Action
C2001xxx Early IPL Initialization Phase
C2001000 Partition auto-IPL during a platform IPL
C2001010 IPL source
C2001100 Adding partition resources to the secondary configuration
C20011FF Partition resources added successfully
C2001200 Checking if IPL is allowed
C20012FF Partition IPL is allowed to proceed
C2001300 Initializing ISL roadmap
C20013FF ISL roadmap initialized successfully
C2001400 Initializing SP™ Communication Area #1
C2001410 Initializing IPL parms
C20014FF IPL parms initialized successfully
C2002xxx SPCN Tower Power On Phase
C2002100 Power on SPCN racks
C2002110 Issuing a rack power on command
C200211F Rack power on command successful
C20021FF SPCN rack power on phase complete
C2002200 Begin acquiring slot locks
C20022FF End acquiring slot locks
C2002300 Begin acquiring VIO slot locks
C20023FF End acquiring VIO slot locks
C2002400 Begin powering on slots
C2002450 Waiting for power on of slots to complete
C20024FF End powering on slots
C2002500 Begin power on VIO slots
C20025FF End powering on VIO slots
C2003xxx Bus Unit ISL Phase
C2003100 Validating ISL command parameters
C2003111 Waiting for Bus object to become operational
C2003112 Waiting for bus unit to become disabled
C2003115 Waiting for creation of bus object
C2003150 Sending ISL command to bus unit
C20031FF Waiting for ISL command completion
C20032FF ISL command complete successfully
C2003300 Start SoftPOR of a failed ISL slot
C2003350 Waiting for SoftPOR of a failed ISL slot
C20033FF Finish SoftPOR of a failed ISL slot
C2004xxx Load Source Device Connection Phase
C2004100 Waiting for load source device to enlist
C2004200 Load source device has enlisted
C2004300 Preparing connection to load source device
C20043FF Load source device is connected
C2005xxx Main Store Dump Phase
C2005100 Preparing to initiate MSD phase
C2005110 Loading SID 82 from load source device
C2005115 MSD Phase I
C2005120 Writing processor registers into SID 82
C2005125 MSD Phase II
C2005130 Writing mainstore pages to the load source device
C2005133 Writing hardware page table to the load source device
C2005135 MSD Phase III
C2005140 Storing (final) SID 82 back to the load source device
C2005150 Allocating the hardware page table
C20051FF MSD processing complete
C2006xxx Load System Licensed Internal Code from Load Source Phase
C2006000 Locating First LID information on the loadsource
C2006005 Clearing all partition main store
C2006010 Locating Next LID information on the loadsource
C2006020 Verifying LID information
C2006030 Priming LP Configuration LID
C2006040 Preparing to initiate LID load from loadsource
C2006050 LP Configuration LID primed successfully
C2006060 Waiting for LID load to complete
C2006100 LID load completed successfully
C2006200 Loading raw kernel memory image
C20062FF Loading raw kernel memory image completed successfully
C2007xxx Load Source Device Disconnection Phase
C2007100 Disconnecting from load source device
C2007103 Removing load source device from LID Manager object
C2007105 Preparing to remove the load source IP from the primary partition
C2007110 Preparing to remove the load source IOP from the primary partition
C2007120 Non-load source IOP has been successfully removed from the primary partition
C2007125 Load source IOP has been successfully removed from the primary partition
C2007130 Calling fatal error on the Transport Manager bus unit object
C20071FF Load source is successfully disconnected
C2008xxx Start Processors Phase
C2008040 Begin transfer slot locks to partition
C2008060 End transfer slot locks to partition
C2008080 Begin transfer VIO slot locks to partition
C20080A0 End transfer VIO slot locks to partition
C20080FF Hypervisor low level session manager object is ready
C2008100 Initializing SP Communication Area #2
C2008104 Loading data structures into mainstore
C2008110 Initializing event paths
C2008120 Starting processors
C2008130 Begin associate of serial ports
C2008138 Associating serial ports to the RPA partition
C200813F End associate of serial ports
C20081FF Processors started successfully, now waiting to receive the continue acknowledgement from System Licensed Internal Code
C2008200 Continue acknowledgement received from System Licensed Internal Code
C20082FF VSP IPL complete successfully