This section describes the C6xxxxxx IPL status progress codes.

For use by service providers.

If a server stalls during an initial program load (IPL) of the operating system, it indicates a problem with the operating system code or hardware configuration. In this case, your only service action is to call your next level of support. If the problem is in the operating system code or hardware configuration, exchanging any hardware FRU will not fix the problem.

Table 1 contains reference information that gives a quick overview of the C6xxxxxx IPL status progress codes and the function associated with each. Please note that at points multiple tasks may be happening at the same time, so the progress code on the panel may not reflect the code module having problems. The mode of the IPL (A, B, or D) determines, in part, which status SRCs are displayed.
The table of C6xxxxxx IPL status progress codes uses the following format:
  • The Progress code column contains characters that represent a particular action your server performs during initialization of the supported operating system.
  • The Description/Action column identifies the action or procedure that produced the progress code.
For more information about using progress codes, see Using progress codes.
Table 1. C6xxxxxx IPL status progress codes
Progress code Description/Action
C6xx1800 Licensed internal code (LIC) SPCN setup.
C60039xx The typical sequence for an A/B/C mode IPL is 3900, 3910, 3911 (warm IPL only), 3912 (warm IPL only), 3913, 3915, 3917, and then other system licensed internal code (LIC) IPL progress codes. The others are seen when an IOP flash update occurs, usually on a D mode and possibly on a side (source) switch between A and B or C.
C6003900 SP transfer control of Bus 1 (BCU switch) to licensed internal code (LIC) is complete and LIC machine facilities component is initialized. IPL of Bus 1 is in progress.
C6003910 Licensed internal code (LIC) has initiated PCI bus reset to all Bus 1 devices, except the SP.
C6003911 Licensed internal code (LIC) has initiated self-test of all Bus 1 devices, except the SP.
C6003912 Licensed internal code (LIC) is initiating IPL of the load source IOP, waiting for the IOP to signal internal reset complete (immediate status acknowledge bit set to 1).
C6003913 Licensed internal code (LIC) is initializing the load source IOP messaging functions.
C6003914 Licensed internal code (LIC) has detected a load source IOP problem and is resetting the IOP, or the IOP has requested a reset after an internal flash memory (LIC) update.
C6003915 Licensed internal code (LIC) has initiated the load source IOP self-load.
C6003916 During self-load, the load source IOP signalled licensed internal code (LIC) that it is initiating an internal flash memory update or other critical function.
C6003917 The load source IOP has completed IPL of its operational load. Licensed internal code (LIC) is waiting for the IOP to report its attached IO resources. This is the last progress code normally displayed regarding load source IPL.
C6004001 Static paging.
C6004002 Start limited paging. Call LID manager.
C6004003 Initialize IPL/termination (IT) data area. Set up node address communication area (NACA) pointer.
C6004004 Check and update MSD SID.
C6004005 Initialize event management is executing.
C6004006 IPL all buses.
C6004007 Start SLID.
C6004008 Initialize I/O service.
C6004009 Initialize I/O machine.
C6004010 Initialize interactive device exerciser (IDE).
C6004011 Initialize remote services.
C6004012 Initialize RMAC component data values.
C6004013 Initialize context management.
C6004014 Initialize RM (component) seize lock.
C6004015 Initialize MISR.
C6004016 Set time of day.
C6004017 Initialize RM (component) process management.
C6004018 Initialize error log.
C6004019 Re-initialize the service processor.
C6004020 Initialize machine services.
C6004021 Initialize performance data collector.
C6004022 Initialize event management.
C6004023 Create MI boundary manager tasks.
C6004024 Disable CPM.
C6004025 Initializes battery test.
C6004026 Hardware card checkout.
C6004027 Start integrated device exerciser (Type C IPL only).
C6004028 Start DST.
C6004029 Make IPL task not critical.
C6004030 Free static storage.
C6004031 Destroy IPL task. DST has been started.
C6004033 Guest partition virtual I/O initialization complete.
C6004050 Storage management recovery is executing.
C6004051 Start LOG is executing.
C6004052 Trace table initialization is executing.
C6004053 Context rebuild is executing. Module called #RCRBCTX.
C6004054 Start product activity log and APPN are executing.
C6004055 Authority recovery is executing.
C6004056 Journal recovery is executing.
C6004057 Data base recovery is executing.
C6004058 Journal synchronization is executing.
C6004059 Commit recovery is executing.
C6004060 Database initialization is executing.
C6004061 Journal IPL cleanup is executing.
C6004062 Commit initialization is executing.
C6004064 System Object Model (SOM) recovery is executing.
C6004065 Start operating system is executing.
C6004100 Searching for load source candidate (D-mode only).
C6004101 Opening media file to install licensed internal code (LIC) service displays with proper national language version.
C6004102 Loading and linking from media-file to install licensed internal code (LIC) service displays with proper national language version.
C6004201 Storage management recovery.
C6004204 Synchronization of mirrored MSD.
C6nn4205 Synchronization of mirrored data (where nn is percent complete).
C6004240 Reclaim main storage.
C6004250 Storage management subset directory recovery.
C6004255 Defragmentation utility.
C6004260 Storage management directory recovery.
C6004272 ASP overflow recovery.
C6004300 Static paging is available for the link/loader.
C6004301 Applying temporary PTFs. If the IPL is terminated at this point, the licensed internal code (LIC) might need to be installed again.
C6004302 Applying modules. If the IPL is terminated at this point, the licensed internal code (LIC) might need to be installed again.
C6004303 Temporarily applied PTFs have reached the static paging phase.
C600432A Resolving references to run Mode A. The system can be safely terminated while this work is being done.
C600432B Resolving references to run Mode B. The system may be safely terminated while this work is being done.
C6004330 Full paging is available; workstation HRI processing.
C6004331 Freeing unused nucleus pages.
C6004332 Permanently applying PTFs. If the IPL is terminated at this point, the licensed internal code (LIC) might need to be installed again.
The following progress codes can appear during an MSD IPL
C6xx4400 Main storage dump manager started (where xx is the number of minutes that have elapsed while waiting for DASD to report in).
C6004401 Some DASD failed to report in.
C6004402 Storage management recovery started.
C6004403 Storage management recovery ended.
C6nn4404 Licensed internal code (LIC) log started. If auto copy in progress, nn is the percent complete. Module called: MsdStartSf.
C6004405 Dump auto copy completed successfully. Module called: MsdStartSf.
C6004406 Shutdown/Programmed IPL started (MSD-related). Module called: MsdStartSf, MsdInit.
The following are DST progress codes for attended IPLs.
C6004500 Verifying network attributes.
C6004501 Looking for the console.
C6004504 Verifying system serial number.
C6004505 Verifying system type.
C6004506 Verifying system-unique ID.
C6004507 Starting before DST DASD checker
C6004508 Verifying system password (if DASD check OK; if not OK this is checked when IPLing past DST).
C6004509 Starting DASD migration function (only if migrating).
C600450A Starting after DST DASD checker (can happen twice).
The following are DST progress codes for unattended IPLs.
C6004500 Verifying network attributes.
C6004502 Starting DST display task (SSP only).
C6004503 Checking possible MRI on media (SSP only).
C6004504 Verifying system serial number.
C6004505 Verifying system type.
C6004506 Verifying system-unique ID.
C6004508 Verifying system password (if DASD check OK).
C600450A Starting after DST DASD checker.
C6004A57 Parallel database recovery is at Pass 1.
C6004A60 Parallel database initialization is at Pass 1.
C6004B57 Parallel database recovery is at Pass 2.
C6004B60 Parallel database initialization is at Pass 2.
C6004C57 Parallel database recovery is at Pass 3.
C6004C60 Parallel database initialization is at Pass 3.
C6004F57 The system is recovering all database objects. This step can take several hours.
C6004F60 The system is examining all objects during database initialization.