(CAxxxxxx) Partition firmware progress codes

This section describes the (CAxxxxxx) partition firmware progress codes.

For use by authorized service providers.

Partition firmware progress codes offer information about the progress of partition firmware as it is initializing. In some cases, a server might hang (or stall) at one of these progress codes without displaying an 8-character system reference code (SRC). Only during such a hang condition should you take any service action related to the progress code.

The table of firmware progress codes uses the following format:
  • The first column, Progress Code, contains characters that represent a particular action your server performs during initialization of firmware.
  • The second column, Description/Action, identifies the action or procedure that produced the progress code. For more information about using progress codes, see Using progress codes.
  • The third column, Failing Item, offers instructions for recovering from a problem or continuing problem analysis. Click a link in this column to view the service actions if you experience a hang condition as previously described.
Notes:
  1. If the control panel displays more than eight characters, use only the first eight characters to find the error in the table. Characters that display after the first eight represent a location code that assists you in diagnosing the problem.
  2. Licensed programs frequently rely on network configuration, and system information stored in the Vital Product Data (VPD) on the control panel. If the Repair Action/Possible Failing FRU entry indicates that you should replace the control panel, swap the VPD module from the old control panel to the new one. If you need to replace the old VPD module, call technical support for recovery instructions. If recovery is not possible, notify the system owner that new keys for licensed programs might be required.
Table 1. (CAxx) Partition firmware progress codes
Progress Code Description/Action Failing Item
CA000000 Process control now owned by partition firmware FWFLASH
CA000020 Checking firmware levels FWFLASH
CA000030 Attempting to establish a communication link by using lpevents FWFLASH
CA000032 Attempting to register lpevent queues FWFLASH
CA000034 Attempting to exchange cap and allocate lpevents FWFLASH
CA000038 Attempting to exchange virtual continue events FWFLASH
CA000040 Attempting to obtain RTAS firmware details FWFLASH
CA000050 Attempting to load RTAS firmware FWFLASH
CA000060 Attempting to obtain open firmware details FWFLASH
CA000070 Attempting to load open firmware FWFLASH
CA000080 Preparing to start open firmware FWFLASH
CA000090 Open firmware package corrupted (phase 1) FWFLASH
CA0000A0 Open firmware package corrupted (phase 2) FWFLASH
CA00D001 PCI probe process completed, create PCI bridge interrupt routing properties FWFLASH
CA00D002 PCI adapter NVRAM hint created; system is rebooting FWFLASH
CA00D003 PCI probing complete PFW1548
CA00D004 Beginning of install-console, loading GUI package FWFLASH
CA00D008 Initialize console and flush queues FWFLASH
CA00D00C   NEXTLVL
CA00D00D Evaluating NVRAM script FWFLASH
CA00D010 First pass open firmware initialization complete; establish parameters for restart FWFLASH
CA00D011 First pass open firmware initialization complete; control returned to initialization firmware FWFLASH
CA00D012 Second pass open firmware initialization complete; control returned to initialization firmware FWFLASH
CA00D013 Run-time open firmware initialization complete; control returned to initialization firmware FWFLASH
CA00D020 The partition firmware is about to load and run the SLIC loader FWFLASH
CA00E101 Create RTAS node FWFLASH
CA00E102 Load/initialize RTAS FWFLASH
CA00E105 Transfer control to operating system (normal boot)

See MAP4040 Isolating LPAR operating system boot problems.

 
CA00E10A Load RTAS device tree FWFLASH
CA00E10B Set RTAS device properties FWFLASH
CA00E130 Build device tree FWFLASH
CA00E134 Create memory node FWFLASH
CA00E135 Create HCA node FWFLASH
CA00E136 Create BSR node FWFLASH
CA00E138 Create options node FWFLASH
CA00E139 Create aliases node and system aliases FWFLASH
CA00E13A Create packages node FWFLASH
CA00E140 Loading operating system

See MAP4040 Isolating LPAR operating system boot problems.

 
CA00E149 Create boot mgr node FWFLASH
CA00E14C Create terminal emulator node FWFLASH
CA00E14D Load boot image

See MAP4040 Isolating LPAR operating system boot problems.

 
CA00E150 Create host (primary) PCI controller node FWFLASH
CA00E151 Probing PCI bus FWPCI5
CA00E152 Probing for adapter FCODE; evaluate if present FWPCI5
CA00E153 End adapter FCODE probing and evaluation FWPCI5
CA00E154 Create PCI bridge node FWPCI5
CA00E155 Probing PCI bridge secondary bus FWPCI5
CA00E156 Create plug-in PCI bridge node FWPCI5
CA00E15B Transfer control to the operating system (service mode boot)

See MAP4040 Isolating LPAR operating system boot problems.

 
CA00E15F Adapter VPD evaluation FWPCI5
CA00E170 Start of PCI bus probe FWPCI5
CA00E172 First pass PCI device probe FWPCI5
CA00E174 Establishing host connection FWHOST
CA00E175 BootP request FWHOST
CA00E176 TFTP file transfer

See MAP4040 Isolating LPAR operating system boot problems.

 
CA00E177 Transfer failure due to TFTP error condition

See MAP4040 Isolating LPAR operating system boot problems.

 
CA00E17B Processor clock speed measurement NEXTLVL
CA00E199 The partition is rebooting to enact changes that were specified in the ELF header of the boot image.

See MAP4040 Isolating LPAR operating system boot problems.

 
CA00E19A NVRAM auto-boot? variable not found - assume FALSE PFW1548
CA00E19B NVRAM menu? variable not found - assume FALSE PFW1548
CA00E19D Create NVRAM node PFW1548
CA00E1A0 User requested boot to SMS menus by using keyboard entry PFW1548
CA00E1A1 User requested boot to open firmware prompt by using keyboard entry PFW1548
CA00E1A2 User requested boot using default service mode boot list by using keyboard entry PFW1548
CA00E1A3 User requested boot using customized service mode boot list by using keyboard entry PFW1548
CA00E1A4 User requested boot to SMS menus by using the Hardware Management Console or a service processor command PFW1548
CA00E1A5 User requested boot to open firmware prompt by using the management console or a service processor command PFW1548
CA00E1A6 User requested boot using default service mode boot list by using the management console or a service processor command PFW1548
CA00E1A7 User requested boot using customized service mode boot list by using the management console or a service processor command PFW1548
CA00E1AA System boot check for NVRAM settings PFW1548
CA00E1AB System booting using the default service mode boot list PFW1548
CA00E1AC System booting using the customized service mode boot list PFW1548
CA00E1AD System booting to the operating system PFW1548
CA00E1AE System booted to SMS multiboot menu by using NVRAM settings FWMBOOT
CA00E1AF System booted to SMS utilities menu by using NVRAM settings PFW1548
CA00E1B1 System booting with management console or hosting-partition directed boot-device repair PFW1548
CA00E1B2 XOFF received, waiting for XON FWVTHMC
CA00E1B3 XON received

This checkpoint flashes by so quickly on the control panel that you can not see it. The progress indicators log might contain a reference to it, which you can access by using the ASMI menus. If a partition hangs on this checkpoint, perform the action specified in the Failing Items column.

FWPCI5
CA00E1B4 Management Console or hosting-partition directed boot-string didn't load an operating system repair NEXTLVL
CA00E1D0 Create PCI SCSI node FWPCI5
CA00E1D3 Create SCSI block device node (SD) FWPCI5
CA00E1D4 Create SCSI byte device node (ST) FWPCI5
CA00E1DC Dynamic console selection FWCONS
CA00E1F0 Start out-of-box experience PFW1542
CA00E1F1 Start self test sequence on one or more devices PFW1542
CA00E1F2 Power on password prompt FWPWD
CA00E1F3 Privileged-access password prompt FWPWD
CA00E1F4 Privileged-access password prompt PFW1542
CA00E1F5 Build boot device list PFW1542
CA00E1F6 Determine boot device sequence PFW1542
CA00E1F7 No boot image located

See MAP4040 Isolating LPAR operating system boot problems.

 
CA00E1F8 Build boot device list for SCSI adapters (displays the location code of the SCSI adapter being scanned) FWPCI5
CA00E1F9 Build boot device list for fibre-channel adapters (displays the location of the SAN adapter being scanned) FWPCI5
CA00E1FA Building device list for SCSI adapters (displays the device ID and device LUN of the devices being scanned) FWPCI5
CA00E1FB Scan SCSI bus for attached devices FWSCSIH
CA00E1FC Build boot device list for SSA adapters (displays the location code of the SSA adapter being scanned). 2107 does not use SSA adapters. Call the next level of support. FWPCI5
CA00E1FE Building device list for Fibre Channel (SAN) adapters (displays the WWPN of the Fibre Channel adapter being scanned) PFW1548
CA00E1FF Build device list for fibre-channel (SAN) adapters (displays the LUN for each device being scanned) PFW1548
CA00E440 Validate NVRAM, initialize partitions as needed PFW1548
CA00E441 Generate/options node NVRAM configuration variable properties PFW1548
CA00E442 Validate NVRAM partitions PFW1548
CA00E443 Generate NVRAM configuration variable dictionary words

Suspect a platform firmware problem if this error code persists.

PFW1548
CA00E701 Create memory VPD PFW1548
CA00E800 Initialize gdata for control panel PFW1548
CA00E820 Initializing lpevent PFW1548
CA00E830 Initializing event scan PFW1548
CA00E840 Initializing hot plug PFW1548
CA00E843 Initializing interface/aix access PFW1548
CA00E850 Initializing dynamic reconfiguration PFW1548
CA00E860 Initializing sensors PFW1548
CA00E865 Initializing VPD PFW1548
CA00E870 Initializing pfds memory manager PFW1548
CA00E875 Initializing rtas_last_error PFW1548
CA00E876 Initializing rtas_error_inject PFW1548
CA00E877 Initializing dump interface PFW1548
CA00E885 Initializing set-power-level PFW1548
CA00E886 Initializing exit2c PFW1548
CA00E887 Initialize gdata for activate_firmware PFW1548
CA00E890 Starting to initialize open firmware PFW1548
CA00E891 Finished initializing open firmware PFW1548
CA00EAA1 Probe PCI-PCI bridge bus  
CA26ttss Waiting for lpevent of type tt and subtype ss

Reboot the system.

FWPCI5
CA2799FD The service processor is receiving a server firmware update module.

This checkpoint alternates in the control panel with CA2799FF. This pair of checkpoints might stay in the display for up to 30 minutes with no other indication of activity. Do not assume that the system is hung until ONLY CA2799FD has remained in the control panel for at least 30 minutes with no other indication of activity.

If the system hangs on CA2799FD (it is NOT alternating with CA2799FF), power off the system and reboot from the permanent side. Reject the image on the temporary side.

 
CA2799FF The service processor is writing a server firmware update module.

This checkpoint alternates in the control panel with CA2799FD. This pair of checkpoints might stay in the display for up to 30 minutes with no other indication of activity. Do not assume that the system is hung until ONLY CA2799FF has remained in the control panel for at least 30 minutes with no other indication of activity.

If the system hangs on CA2799FF (it is NOT alternating with CA2799FD), power off the system and reboot from the permanent side. Reject the image on the temporary side.