HSCL 03xx
This section lists the HSCL 03xx error codes.
Note: The following error messages and recovery actions might include procedures
that are not available on the DS8000®
management console. If in doubt, contact the next level of support. If you are
instructed to shut down the management console, then you must first verify that the customer is not
currently performing DS8000 actions through
the management console ESSNI connection.
| Error code | Message | Recovery action |
|---|---|---|
| 03EA | There is an insufficient number of processors: Obtained - {0}, Required - {1}. Check that there are enough processors available to activate the partition. If not, create a new profile or modify the existing profile with the available resources, and then activate the partition. If the partition must be activated with the specified number of processors, deactivate any active logical partitions using the resource, and then activate the partition. |
|
| 03EB | Could not allocate the I/O slot for activation in {0}. Check that the specified I/O is available to activate the partition. If not, create a new profile or modify the existing profile with the available resources, and then activate the partition. If the partition must be activated with these resources, deactivate any running partitions using the resource, and then activate this partition. |
|
| 03EC | There is not enough memory: Obtained - {0}, Required - {1}. Check that there is enough memory available to activate the partition. If not, create a new profile or modify the existing profile with the available resources, and then activate the partition. If the partition must be activated with these resources, deactivate any running partition or partitions using the resource, and then activate this partition. |
|
| 03ED | The I/O unit specified by this ID cannot be found and might have been deleted from the managed system. Modify the profile. | Modify the partition profile so that the unit that cannot be found is no longer part of the profile's resources. |
| 03EE | The specified slot number cannot be found. Ensure the profile is not using I/O unit slots that do not exist in the managed system. | The adapter specified cannot be found. Modify partition profiles so that the slot that cannot be found is not part of any partition profile. |
| 03EF | The number of system units, slots, and I/O required and desired information stored in the properties do not match. The profile might be corrupted. Perform the Restore Profile Data task. |
|
| 03F0 | Could not allocate the I/O slot for activation in I/O drawer {0}. Slot {1} is currently being used by another partition. Perform one of the following three actions: 1) Remove this I/O slot from the profile, 2) Change the I/O slot from Required to Desired in the profile, or 3) Remove the I/O slot from the other partition. | Perform one of the following actions:
|
| 03F4 | Not enough processing resources to meet the allocation setting |
|
| 03F5 | There is an insufficient amount of shared processing resources: Virtual processor obtained - {0}, processing units obtained - {1}, Required virtual processors - {2}, Required processing units - {3}. Check that there is enough processing resources available to activate the partition. If not, create a new profile or modify the existing profile with the available resources, and then activate the partition. If the partition must be activated with the specified amount of processing resources, deactivate any active partitions using the resource then activate this partition. |
|
| 03F6 | The 5250 CPW needed by the partition exceeds the system limit. Amount allowable at this point is {0}. |
|
| 03F7 | Insufficient amount of 5250 CPW for allocation: Obtained - {0}, required - {1}. |
|
| 03F8 | The 5250 CPW set by user is below the partition minimum allowed: minimum = {0}. |
|
| 03F9 | Not enough memory resources to meet the allocation setting. |
|
| 03FA | Unable to gather I/O information of the managed system. |
|
| 03FB | Unable to gather virtual I/O information of the managed system. |
|
| 03FC | The MAC address prefix specified was not valid. The MAC address prefix must be six characters long, and only contain hexadecimal values (0-9 and A-F). |
|
| 03FD | The MAC address prefix cannot have the multicast bit on. The multicast bit is 0x010000. |
|
| 03FE | There was an error updating a virtual Ethernet adapter MAC address. |
|
| 03FF | Failed to extract system resources information. Ensure the managed system is powered on. |
|