Note: The following error messages and recovery actions might include procedures that are not available on the DS8000® management console. If in doubt, contact the next level of support. If you are instructed to shut down the management console, then you must first verify that the customer is not currently performing DS8000 actions through the management console ESSNI connection.
Table 1. HSCL: 07xx error codes
Error code Messages Recovery action
07D1 This logical partition profile is currently active in its logical partition and cannot be modified or deleted. To make the profile inactive, bring the partition to the Not Activated state, and then repeat the operation. Partition profiles that are active in a logical partition cannot be deleted.
  1. Perform an operating system reset on the partition to bring it to the Not Activated state, at which time the profile will no longer be active. See MAP6660 Operation procedures that do not apply to DS8000.
  2. If it still fails, contact your next level of support.
07D2 This logical partition profile is the logical partition's default profile and cannot be deleted. If you still want to delete it, change the default profile for this logical partition or, if necessary, create another logical partition profile to be the default profile. All logical partitions must have at least one partition profile, which is designated as the default profile because it is the profile implicitly used when the logical partition is activated with no profile specified.
  1. If you still want to delete it, change the default profile for this logical partition (create another logical partition profile if necessary).
  2. If it still fails, contact your next level of support.
07D3 The logical partition profile could not be found in the management console save area. The management console is either out of sync with the console save area, or the console save area has been corrupted. Rebuild this logical partition profile's managed system.
  1. Ensure that the inputs are correct.
  2. Restore the profile data. See MAP6660 Operation procedures that do not apply to DS8000 for details.
  3. If the problem persists, contact your next level of support.
07D4 A profile named {0} already exists for this logical partition in the management console save area. Choose a different name for the new system profile.
  1. All partition profiles for a logical partition must have unique names. Choose a different name for the new profile.
  2. If the problem persists, contact your next level of support.
07D8 Deleting default profile associations within the current context is not allowed.  
07D9 Setting a default profile association is only allowed during create.  
07DA The logical partition profile used for the operation cannot be found in the profile data.
  1. Verify that you entered the correct information.
  2. If the problem persists, contact your next level of support.
07DB An attempt to create a profile failed.
  1. Try the task again.
  2. If problem persists, contact your next level of support.
07DC An attempt to modify a profile failed.
  1. Try the task again.
  2. If problem persists, contact your next level of support.
07DD The LPAR profile's processing resources setting is not valid. Check profile processing resource setting.
  1. Check the processing resources setting.
  2. If the problem persists, contact your next level of support.
07DE The LPAR profile's 5250 CPW setting is not valid. Check profile processing resource setting.
  1. Check the 5250 CPW.
  2. If the problem persists, contact your next level of support.
07DF Virtual slot 0 and 1 are set to default as virtual serial adapters when a partition is created. No modification can be made regarding these 2 slots.  
07E0 The partition profile could not be found in the database. Perform a rebuild managed system operation, and try again.
  1. Rebuild the managed system. See MAP6620 Rebuilding managed system information for details.
  2. Retry the task.
  3. If the problem persists, contact your next level of support.
07E1 An error occurred while changing the default profile for the partition. Please retry the operation.
  1. Rebuild the managed system. See MAP6620 Rebuilding managed system information for details.
  2. Retry the task.
  3. If the problem persists, contact your next level of support.
07E2 Required processor information in the LPAR profile is not set. Please check your profile and try again.
  1. Ensure that the setting is valid.
  2. Retry the task.
  3. If the problem persists, contact your next level of support.
07E3 Failed to delete LPAR profile, {0}, from partition, {1}.
  1. Retry the task.
  2. If the problem persists, contact your next level of support.
07E5 The critical I/O setting is incorrect. Check the setting and try again.
  1. Ensure the tagged I/O setting is correct.
  2. Retry the task.
  3. If the problem persists, contact your next level of support