Note: The following error messages and recovery actions might include procedures that are not available on the DS8000® management console. If in doubt, contact the next level of support. If you are instructed to shut down the management console, then you must first verify that the customer is not currently performing DS8000 actions through the management console ESSNI connection.
Table 1. HSCL: 09xx system profile error codes
Error code Message Recovery action
09C6 Could not find the system profile in memory. It might be corrupted. Restore the profile data. The system profile might be corrupted.
  1. Restore the profile data. See MAP6660 Operation procedures that do not apply to DS8000 for details.
  2. If the problem persists, delete and re-create a new system profile. Refer to MAP6660 Operation procedures that do not apply to DS8000 for details.
  3. If the problem persists, contact your next level of support.
09C7 A system profile named {0} already exists for this managed system in the Hardware Management Console save area. Choose a different name for the new system profile. Every system profile created for an individual managed system must have a unique name. Choose a different name for the new system profile. If it still fails, contact your next level of support.
09C8 Could not open the Copy System Profile dialog. Try again.
  1. Log off the management console, and log back in.
  2. Try the task again. See MAP6660 Operation procedures that do not apply to DS8000 for details.
  3. If it still fails, contact your next level of support.
09C9 Could not copy the system profile {0}. Try again.
  1. Log off the management console, and log back in.
  2. Try the task again. See MAP6660 Operation procedures that do not apply to DS8000 for details.
  3. If it still fails, contact your next level of support.
09CA Could not delete the system profile. Try the task again.
  1. Log off the management console, and log back on.
  2. Try the task again.
  3. If the problem persists, contact your next level of support.
09CF Validation of system profile failed. Retry the operation.
  1. Retry the operation.
  2. If the problem persists, contact your next level of support.
09D0 Cannot validate system profile if the managed system is not in Operating or Standby state.
  1. Ensure that the managed system is in the Operating or Standby state and then retry the operation.
  2. If the problem persists, contact your next level of support.
09D2 The following partition or partitions failed to activate: {0} A logical partition that is part of the system profile failed to activate.
  1. Ensure that you have enough free resources to activate the desired partition profile.
  2. If so, rebuild the managed system. See MAP6620 Rebuilding managed system information for details.
  3. Retry the operation.
  4. If the problem persists, contact your next level of support.
09D3 An unknown error occurred during system profile activation. Please retry the operation.
  1. Rebuild the managed system. See MAP6620 Rebuilding managed system information for details.
  2. Retry the operation.
  3. If the problem persists, contact your next level of support.
09D4 Update of the system profile failed. Please retry the operation.
  1. Rebuild the managed system. See MAP6620 Rebuilding managed system information for details.
  2. Retry the operation.
  3. If the problem persists, contact your next level of support.
09D5 An unknown error occurred during system profile creation. Please retry the operation.
  1. Rebuild the managed system. See MAP6620 Rebuilding managed system information for details.
  2. Retry the operation.
  3. If the problem persists, contact your next level of support.
09D6 An unknown error occurred during deletion of the system profile. Please retry the operation.
  1. Rebuild the managed system. See MAP6620 Rebuilding managed system information for details.
  2. Retry the operation.
  3. If the problem persists, contact your next level of support.
09D7 The system profile that you have chosen to validate could not be found. The system profile might be corrupted.
  1. Restore the profile data. See MAP6660 Operation procedures that do not apply to DS8000 for details.
  2. If the problem persists, delete and re-create a new system profile.
  3. If the problem persists, contact your next level of support.
09D8 System profile {0} could not be {1} because profile {2} was not found in the managed system. A profile that is part of the system profile cannot be found in the managed system.
  1. Rebuild the managed system. See MAP6620 Rebuilding managed system information for details.
  2. Retry the operation.
  3. If the problem persists, contact your next level of support.
09D9 System profile {0} could not be {1} because profiles {2} and {3} belong to the same partition. Take one of the profiles out of the system profile list and try again. There is more than one profile in the system profile that belongs to the same partition.
  1. Ensure that each partition has at most one profile in the system profile, and retry the operation.
  2. If the problem persists, contact your next level of support.
09DA System profile {0} could not be {1} because LPAR profile {2}, belonging to partition {3}, is listed more than once. Take one of the profiles out of the system profile list and try again. A profile is listed more than once in the system profile.
  1. Ensure that all partition profiles are only listed once in the system profile, and retry the operation.
  2. If the problem persists, contact your next level of support.
09DB Partition {0} could not be activated because it is already active. This error occurs when a logical partition listed in the system profile is already activated.
  1. If the logical partition is not activated, rebuild the managed system. See MAP6620 Rebuilding managed system information for details.
  2. Retry the operation.
  3. If the problem persists, contact your next level of support.
09DC System profile {0} could not be {1} because profile {2} is a full system partition profile. There cannot be any other partition profiles listed in the system profile. If a full system partition profile is part of a system profile, there can be no other partition profiles listed in that system profile.
  1. Either take all other profiles except the full system partition profile out of the system profile, or remove the full system partition profile from the system profile.
  2. Retry the operation.
  3. If the problem persists, contact your next level of support.
09DD The partition profile ID {0} does not correspond to a valid profile. Please retry the command.
  1. Rebuild the managed system. See MAP6620 Rebuilding managed system information for details.
  2. Retry the operation.
  3. If the problem persists, contact your next level of support.
09DE The system profile cannot be created because no user-defined name was given. Ensure to enter a user-defined name, and try the operation again.
  1. No user-defined system profile name was given during system profile creation. Retry the creation operation again, this time making sure to enter a user-defined name.
  2. If the problem persists, contact your next level of support.
09DF The system profile cannot be created because there are no partition profiles currently included in the system profile. Please specify partition profiles for the system profile or click \"Cancel\".
  1. Partition profiles for the system profile must be specified during system profile creation. Retry the system profile creation operation, making sure to add at least one partition profile to the system profile.
  2. If the problem persists, contact your next level of support.
09E0 The profile {0} belongs to a partition that currently has a profile already included in the system profile. Please select a profile from a different partition or first remove the conflicting partition's profile from the system profile, and then add the desired profile again.  
09E1 There is currently a system profile with the name {0} created for this system. Please enter a unique name.
  1. If there is not a system profile with the specified name displayed in the console, refresh the console and try the command again.
  2. If it fails again, rebuild the managed system. See MAP6620 Rebuilding managed system information for details.
  3. Reboot the management console and then try the task again.
  4. If the problem persists, contact your next level of support.
09E2 There is currently a system profile with the name {0} created for this system. Please enter a unique name. This message is for informational purposes only regarding the outcome of system profile validation. No recovery action should be taken.
09E3 Activation results for system profile {0}:{1}. This message is for informational purposes only regarding the outcome of system profile validation. No recovery action should be taken.