| Error code | Message | Recovery action |
|---|---|---|
| 150B | Cannot change the I/O pools of the partition since the partition is still using an I/O adapter participating in one of the pool IDs. | |
| 150C | Cannot use the I/O adapter: {0} since the partition is not part of the pool this adapter belongs to. | |
| 150D | Cannot use the I/O adapter: {0} because it is not available. |
|
| 150E | Cannot use the I/O adapter: {0} since it is configured under an I/O unit marked as switchable. | |
| 150F | Cannot vary off the I/O adapter: {0} because it is still in use by the partition. | |
| 1510 | This I/O adapter is marked as multi-hub reserving for shark partition. | |
| 1511 | Cannot use the I/O adapter: {0} because it is either used by another partition or an allocation is already in progress. | |
| 1512 | Cannot vary off the I/O adapter: {0} because the partition is not ready to release the adapter. | |
| 1513 | Cannot change the OptiConnect setting since the communication with the partition is still active. | |
| 1514 | The virtual I/O slot number specified is not valid. |
|
| 1515 | Cannot use a virtual slot number greater or equal to the maximum number of virtual slots allowed with this partition. |
|
| 1516 | Cannot specify additional virtual LAN IDs since this virtual Ethernet adapter is not IEEE compatible. |
|
| 1517 | The virtual slot number specified to query or set virtual slot information is not valid. |
|
| 1518 | The virtual slot state specified is not valid. |
|
| 1519 | The number of virtual slots specified is not valid. |
|
| 151A | A virtual Ethernet trunk adapter with the same MAC address already exists. |
|
| 151B | Unable to delete the partition when there is a virtual terminal connection opened. |
|
| 151C | Server adapter setting of the virtual slot: {0} is not valid. |
|
| 151D | The virtual adapter: {0} cannot be set up for management console connection. |
|
| 151E | Cannot have multicast MAC address for the virtual Ethernet trunk adapter. |
|
| 1523 | Shared pool ID specified is not valid. |
|
| 152A | Cannot switch out of manufacturing default mode because the managed system is in EEH. | |
| 152D | The managed system is not ready for the management console to extract partition and resource information. |
|
| 1537 | The partition is not responsive for dynamic resource configuration changes. |
|
| 1538 | There is an insufficient amount of memory for maintaining system firmware. | |
| 1539 | Memory configuration for the partition cannot be satisfied due to system memory usage limitation. | |
| 1550 | Firmware command: {0} failed due to the following {1} errors:{2} |
|
| 1551 | The firmware extended error code is {0}. |
|
| 1552 | The firmware operation failed with extended error. |
|
| 157D | Unable to query the association within the managed system. Log in as the proper user and use the correct association method. | |
| 157E | Unable to edit instance of {0}. Check user permissions, and then log in as the proper user and try editing again. |
|
| 157F | Cannot find an instance of the object specified. Either there is no instance and it must be created or a path to the object was incorrect. |
|
| 1580 | Improper number of arguments passed in: passed in = {0}, expected = {1}. Check the parameters of the invoked method. |
|
| 1581 | The method name {0} passed in the invoke method does not match the name of the method you are trying to invoke. Check the method name and the required parameters. |
|
| 1582 | The wrong path is being used for the object manager - {0}. Check the code for build CIMObjectPath and its contents. |
|
| 1583 | The wrong object manager method is being invoked. |
|
| 1584 | You do not have the proper authorization or permission to perform this task. Log in as the proper user and try again. | Log in with appropriate permissions to perform the task. If the problem persists, contact your next level of support. |
| 1585 | There was an unknown error while querying the object manager database. |
|
| 1586 | Cannot find an instance with object manager of {0}. |
|
| 1588 | An exception was encountered while calling the method named {0}. |
|
| 159B | The group number is invalid. Group numbers cannot contain any letters or characters other than the numbers 0 through 9. | Enter the new group number again without alphabetic characters. |
| 159C | The Workload Management group number has to be between {0} and {1}. | Enter a number inside the valid range for workload management group numbers. |
| 15E7 | The profile you tried to activate does not belong to the partition {0} you specified. | Verify that you selected the correct LPAR profile to activate. If the operation still fails, contact your next level of support |