HSCL 17xx
This section lists the HSCL 17xx error codes.
Note: The following error messages and recovery actions might include procedures
that are not available on the DS8000®
management console. If in doubt, contact the next level of support. If you are
instructed to shut down the management console, then you must first verify that the customer is not
currently performing DS8000 actions through
the management console ESSNI connection.
| Error code | Message | Recovery action |
|---|---|---|
| 1771 | Could not create console information and set it with the managed system. Perform the rebuild managed system operation. | Rebuild the managed system. See MAP6620 Rebuilding managed system information for details. |
| 1772 | Could not set management console information. Perform the rebuild managed system operation. | Rebuild the managed system. See MAP6620 Rebuilding managed system information for details. |
| 1773 | Invocation of the management console information method failed. Perform the rebuild managed system operation. | Rebuild the managed system. See MAP6620 Rebuilding managed system information for details. |
| 1774 | Unable to get the defined slot number for management console information slots. Perform the rebuild managed system operation. | Rebuild the managed system. See MAP6620 Rebuilding managed system information for details. |
| 1776 | Could not get the management console information. Perform the rebuild managed system operation. | Rebuild the managed system. See MAP6620 Rebuilding managed system information for details. |
| 1777 | Failed to construct the management console information string. Perform the rebuild managed system operation. | Rebuild the managed system. See MAP6620 Rebuilding managed system information for details. |
| 1778 | Could not create the management console instance in the object manager. Restart the management console. |
|
| 1779 | Could not create the management console motherboard instance in the object manager. Restart the management console. |
|
| 177A | Could not create the management console chassis instance in the object manager. Restart the management console. |
|
| 177B | Could not create the management console network setting instance in the object manager. Restart the management console. |
|
| 177C | Could not create the management console partition management instance in the object manager. Restart the management console. |
|
| 177D | Could not create the management console operating system instance in the object manager. Restart the management console. |
|
| 177E | Could not create the management console memory instance in the object manager. Restart the management console. |
|
| 177F | Could not delete the management console instance. |
|
| 1780 | Could not delete management console and its related instances. |
|
| 1781 | Could not obtain management console's VPD information. Restart the management console. |
|
| 1782 | Could not delete the management console Motherboard instance and its associations. |
|
| 1783 | Could not delete the management console chassis instance and its associations. |
|
| 1784 | Could not delete the management console network setting instance and its associations. |
|
| 1785 | Could not delete the management console partition management instance and its associations. |
|
| 1786 | Could not delete the management console operating systems instance and its associations. |
|
| 1787 | Could not delete the management console memory instance and its associations. |
|
| 1788 | Management console information data has exceeded the 256 characters limit. Please reduce the length of your host name. |