HSCL 29xx

This section lists the HSCL 29xx error codes.

Note: The following error messages and recovery actions might include procedures that are not available on the DS8000® management console. If in doubt, contact the next level of support. If you are instructed to shut down the management console, then you must first verify that the customer is not currently performing DS8000 actions through the management console ESSNI connection.
Table 1. HSCL: 29xx user management error codes
Error code Message Recovery action
2901 This logical partition is not capable of adding, removing, or moving processors dynamically. Ensure your logical partitions are capable of performing dynamic logical partition operations.
2902 The destination logical partition is not capable of adding, removing, or moving processors dynamically. Ensure your logical partitions are capable of performing dynamic logical partition operations.
2903 Your processor request goes below the profile's required processor limit. You can remove or move {0} or fewer processors. Retry the operation. Retry the operation, entering a smaller number of processors.
2904 Your processor request exceeds the profile's maximum processor limit. You can add or move up to {0} processors. Retry the operation. Retry the operation, entering a smaller number of processors.
2905 This logical partition is not capable of adding, removing, or moving memory dynamically. Ensure your logical partitions are capable of performing dynamic logical partition operations.
2906 The destination logical partition is not capable of adding, removing, or moving memory dynamically. Ensure your logical partitions are capable of performing dynamic logical partition operations.
2907 Your memory request exceeds the profile's maximum memory limit. You can add or move up to {0} MBs of memory. Retry the operation.
  1. Retry the task and request a smaller memory amount.
  2. Reset the logical partition, reactivate the logical partition, and then retry the operation.
  3. If the problem persists, contact your next level of support.
2908 Your memory request goes below the profile's minimum memory limit. You can remove or move up to {0} MB of memory. Retry the operation.
  1. Retry the task and request a smaller memory amount.
  2. Reset the logical partition, reactivate the logical partition, and then retry the operation.
  3. If the problem persists, contact your next level of support.
2909 Your memory request exceeds the total available memory of the managed system. You can add up to {0} MB of memory. Retry the operation.
  1. Check the available memory of the managed system, retry the task and request a smaller memory amount.
  2. Reset the logical partition, reactivate the logical partition, and then retry the operation.
  3. If the problem persists, contact your next level of support.
290B This logical partition is not capable of adding, removing, or moving I/O slots dynamically. Ensure your logical partitions are capable of performing dynamic logical partition operations.
290C The destination logical partition is not capable of adding, removing, or moving I/O slots dynamically. Ensure your logical partitions are capable of performing dynamic logical partition operations.
2912 The managed system is powered off. You must power on the managed system to perform a dynamic logical partition operation.
  1. Ensure the managed system is powered on.
  2. Rebuild managed system. See MAP6620 Rebuilding managed system information for details.
  3. If the problem persists, contact your next level of support
2914 The quantity to be added exceeds the available resources.
  1. Ensure that memory is available in the managed system.
  2. Retry the operation.
  3. If the problem persists, contact your next level of support.
2916 The partition could not be found in the database. Perform a rebuild managed system operation, and try again.
  1. Rebuild the managed system. See MAP6620 Rebuilding managed system information for details.
  2. Retry the task.
  3. If the problem persists, contact your next level of support
2925 An unknown error occurred during the add Virtual adapter operation. Please retry the operation.
  1. Retry the operation.
  2. If the problem persists, contact your next level of support.
2926 An unknown error occurred during the remove Virtual adapter operation. Please retry the operation.
  1. Retry the operation.
  2. If the problem persists, contact your next level of support.
2927 Dynamic logical partition MOVE Processing resources failed: {0}.
  1. Retry the task.
  2. Rebuild the managed system. See MAP6620 Rebuilding managed system information for details.
  3. Retry the task.
  4. If the problem persists, contact your next level of support
2928 Dynamic logical partition ADD I/O resources failed: {0}.
  1. Ensure you have the resources available to perform the operation.
  2. Retry the operation.
  3. If operation still fails, rebuild the managed system and try the operation again. See MAP6620 Rebuilding managed system information for details.
  4. If the problem persists, contact your next level of support.
2929 Dynamic logical partition REMOVE I/O resources failed: {0}.
  1. Ensure you have the resources available to perform the operation.
  2. Retry the operation.
  3. If operation still fails, rebuild the managed system and try the operation again. See MAP6620 Rebuilding managed system information for details.
  4. If the problem persists, contact your next level of support.
2930 Dynamic logical partition MOVE I/O resources failed: {0}.
  1. Ensure you have the resources available to perform the operation.
  2. Retry the operation.
  3. If operation still fails, rebuild the managed system and try the operation again. See MAP6620 Rebuilding managed system information for details.
  4. If the problem persists, contact your next level of support.
2931 Dynamic logical partition ADD Memory resources failed: {0}.
  1. Retry the operation.
  2. If the problem persists, contact your next level of support.
2932 Dynamic logical partition REMOVE Memory resources failed: {0}.
  1. Retry the operation.
  2. If the problem persists, contact your next level of support.
2933 Dynamic logical partition MOVE Memory resources failed: {0}.
  1. Retry the operation.
  2. If the problem persists, contact your next level of support.
2934 The operating system drmgr command failed. Please consult the appropriate operating system log files for further information and retry the operation if desired.
  1. Retry the operation.
  2. If the problem persists, contact your next level of support.
2935 {0} operation for {1} resource did not finish completely in the timeout value specified. The requested number was {2}. The success number is {3}. Please increase the timeout value if needed.
  1. Retry the operation.
  2. If the problem persists, contact your next level of support.
2936 {0} operation for {1} resource failed.
  1. Ensure the network connection between the management console and the partition is working.
  2. Retry the operation.
  3. If the problem persists, contact your next level of support
2937 {0} operation for {1} has completed, but only {3} out of {2} were successful. The partition standard output/error is not available.  
2938 {0} operation for {1} resource failed. The RPA partition standard output/error is not available.  
2939 {0} operation for {1} has completed, but only {3} out of {2} were successful. The partition standard output is: {4}. The AIX standard error is: {5}.  
293A {0} operation for {1} has completed, but only {3} out of {2} were successful. The partition command is: {4}. The partition standard output is: {5} The partition standard error is: {6}.  
293B The return code is {0}. The partition return code is {1}.  
293D Partition {0} is not in the correct state to perform dynamic logical partitioning operations. Dynamic logical partitioning operations can only be performed on running partitions.
  1. Verify that the partition is in the Running state, and retry the operation.
  2. If the problem persists, contact your next level of support
2940 An unknown Dynamic logical partition error has occurred. Try the operation again.
  1. Retry the operation.
  2. If the problem persists, contact your next level of support.
2941 There are no processors available for dynamic logical partitioning on this partition.
  1. Ensure that there are available processors in the managed system.
  2. Retry the operation.
  3. If the problem persists, contact your next level of support.
2942 There is no memory available for dynamic logical partitioning on this partition.
  1. Ensure that there are available processors in the managed system.
  2. Retry the operation.
  3. If the problem persists, contact your next level of support.
2944 The I/O slot cannot be found. Ensure that the correct slot ID and unit ID were entered.
  1. Ensure the inputs are correct.
  2. Rebuild managed system. See MAP6620 Rebuilding managed system information for details.
  3. Retry the task.
  4. If the problem persists, contact your next level of support
2945 The shutdown operation on the logical partition failed. The return code is {0}.
  1. Retry the operation.
  2. If the problem persists, contact your next level of support.
2946 The logical partition could not be shut down because the management console's communication to the partition failed. The return code is {0}.
  1. Ensure the network connection between the partition and the management console is working.
  2. Restart the management console and retry the operation.
  3. If the problem persists, contact your next level of support.
2947 An error occurred while trying to restore stopped processors. There were {0} processors restored before the error occurred.  
2949 An error occurred while trying to restore stopped I/O devices. There were {0} devices restored before the error occurred.  
294A The I/O slot cannot be found or it is required. Ensure that the valid slot ID and unit ID were entered.
  1. Ensure the inputs are correct.
  2. Ensure the adapter is not marked as required.
  3. Rebuild managed system. See MAP6620 Rebuilding managed system information for details.
  4. If the problem persists, contact your next level of support
294C Dynamic logical partition ADD Virtual I/O resources failed: {0}.
  1. Correct the error and retry the operation.
  2. If the problem persists, contact your next level of support.
294D Dynamic logical partition REMOVE Virtual I/O resources failed: {0}.
  1. Correct the error and retry the operation.
  2. If the problem persists, contact your next level of support.
294E Dynamic logical partition ADD Processing resources failed: {0}.
  1. Retry the operation.
  2. If operation still fails, perform a Rebuild Managed System operation, and try the operation again. See MAP6620 Rebuilding managed system information for details.
  3. If the problem persists, contact your next level of support.
294F Dynamic logical partition REMOVE Processing resources failed: {0}.
  1. Retry the operation.
  2. If operation still fails, perform a Rebuild Managed System operation, and try the operation again. See MAP6620 Rebuilding managed system information for details.
  3. If the problem persists, contact your next level of support.
2950 Dynamic logical partition operation on PCI Host Bridge failed.
  1. Ensure you have the resources available to perform the operation.
  2. Retry the operation.
  3. If operation still fails, perform a Rebuild Managed System operation, and try the operation again. See MAP6620 Rebuilding managed system information for details.
  4. If the problem persists, contact your next level of support.
2952 The dynamic logical partitioning requested could not be completed due to an unknown error(s) in the local system. Please retry the operation
  1. Retry the operation.
  2. If the problem persists, contact your next level of support.
2970 The IOServer command has failed because of the following reason: {0}. Please retry the command. If the problem persists, contact your next level of support.
2971 The IOServer command fails because the partition {0} is unknown to RMC/LparCmdRM. This could be because of a firewall or an improper network setup causing RMC not to recognize the partition. Please check the system network setup. This could be caused by a firewall or an improper network setup causing Resources Monitoring Control (RMC) not to recognize the partition. Please check the system network setup.
2972 There is no active session between the management console and the partition.
  1. There could be a short interruption in the network causing Resources Monitoring Control (RMC) to not recognize the partition.
  2. Retry the operation later or restart the management console.
  3. If the problem persists, contact your next level of support.
2973 The IOServer command contained illegal characters such as ; or >. There are illegal characters in the IOServer command. Please check the IOServer command to make sure it does not include illegal characters, and try the task again.