Note: The following error messages and recovery actions might include procedures that are not available on the DS8000® management console. If in doubt, contact the next level of support. If you are instructed to shut down the management console, then you must first verify that the customer is not currently performing DS8000 actions through the management console ESSNI connection.
Table 1. HSCL: 9xxx error codes
Error code Message Recovery action
9000 This operation is not allowed because Capacity on Demand is not supported on the managed system.  
9003 The operation has failed on the managed system. Retry the operation. If the failure persists, contact your hardware service representative.
  1. Retry the operation.
  2. If the problem persists, contact your next level of support.
9004 The information could not be retrieved from the managed system.
  1. Retry the operation.
  2. If the problem persists, contact your next level of support.
9005 The information could not be retrieved from the managed system. Contact your next level of support.
  1. Retry the operation.
  2. If the problem persists, contact your next level of support.
9006 The information could not be retrieved from the managed system. Retry the operation. If the problem persists, contact your next level of support.
  1. Retry the operation.
  2. If the problem persists, contact your next level of support.
9007 This operation is not allowed because Capacity on Demand for processors is not supported on the managed system.  
9008 This operation is not allowed because Capacity on Demand for memory is not supported on the managed system.  
9009 This operation is not allowed because Capacity Upgrade on Demand for processors is not supported on the managed system.  
900A This operation is not allowed because Capacity Upgrade on Demand for memory is not supported on the managed system.  
900B This operation is not allowed because On/Off Capacity on Demand for processors is not supported on the managed system.  
900C This operation is not allowed because On/Off Capacity on Demand for memory is not supported on the managed system.  
900D This operation is not allowed because Reserve Capacity on Demand is not supported on the managed system.  
900E This operation is not allowed because Trial Capacity on Demand for processors is not supported on the managed system.  
900F This operation is not allowed because Trial Capacity on Demand for memory is not supported on the managed system.  
9010 This operation is only allowed when the managed system is in the Standby or Operating state.
  1. Ensure that the managed system is in the Operating or Standby state, and then try the operation again.
  2. If the problem persists, contact your next level of support.
9011 This operation is not allowed because unreturned On/Off CoD processors are currently in use on the managed system. Make the On/Off CoD processors available to be reclaimed by the system by removing them from partitions, and then retry the operation. There are unreturned On/Off CoD processors currently in use on the managed system which must be made available to be reclaimed by the system before this operation will be allowed.
  1. Check the number of unreturned On/Off CoD processors, and then remove processors from partitions, if necessary, until the number of available processors is equal to or greater than the number of On/Off CoD processors that were unreturned.
  2. To remove them, either use dynamic partitioning to remove the On/Off CoD processors from a running partition, or shutdown and then delete the partition to free up the processors.
  3. Retry the operation.
9015 The managed system cannot currently process this operation. This condition is temporary. Please retry the operation.
  1. The managed system is busy, but the condition is temporary. Retry the operation after a period of time.
  2. If the condition persists, contact your next level of support.
9016 You did not enter the CoD code correctly. Try again. The CoD code was entered incorrectly. Try the operation again by carefully re-entering the code exactly as it was given to you.
9017 {0} The sequence number of the CoD code indicates that this code has been used before. Obtain a new CoD code and try again. The CoD code that was entered has been used before and cannot be used more than once. Check to make sure you are entering a new CoD code and try again.
9018 {0} The CoD feature for which the CoD code was generated is not supported on the managed system. The CoD feature for which this CoD code was generated is not supported on the managed system. Verify that the CoD code you are trying to enter was generated for the managed system on which you are trying to enter it.
9019 The CoD code has been rejected by the managed system because too many invalid CoD codes have been entered. The managed system must be rebooted before another CoD code will be accepted.
  1. Restart the management console.
  2. Try the task again with a valid CoD code.
901A There are not enough inactive processors available to accept this CoD code because On/Off CoD processors are currently activated. Remove processors from partitions, if necessary, until the number of On/Off CoD processors that are activated have been made available to be reclaimed by the system. Then deactivate the On/Off CoD processors, and re-enter the CUoD processor activation code. There are not enough inactive processors currently available to accept this CoD code for CUoD processors, because On/Off processors are currently activated.
  1. Check the number of available processors, and then remove processors from partitions, if necessary, until the number of available processors is equal to or greater than the number of On/Off processors that have been activated. To do this, either use dynamic partitioning to remove the On/Off CoD processors from a running partition, or shutdown and then delete the partition to free up the processors.
  2. If the problem persists, contact your next level of support.
9024 {0} The CoD code cannot be accepted because On/Off CoD resources are currently activated. If necessary, remove resources from partitions until the amount of On/Off CoD resources that are activated have been made available to be reclaimed by the system. Then deactivate the On/Off CoD resources, and re-enter the On/Off capacity termination code. The CoD code to terminate On/Off CoD cannot be accepted, because On/Off resources are currently activated.
  1. Check the amount of available resources, and then remove resources from partitions, if necessary, until the amount of available resources is equal to or greater than the amount of resources that have been activated for CoD. Do this by either using dynamic partitioning to remove the On/Off resources from a running partition, or shutdown and delete the partition to free up the resources.
  2. Retry the operation.
9026 The number of On/Off CoD processors requested exceeds the number of inactive processors that are currently available on the managed system. Reduce the number of processors requested and try again.
  1. Reduce the number of processors requested.
  2. Retry the operation.
902A There are insufficient resources available to accept the On/Off CoD activation request. The number of processors multiplied by the number of days cannot exceed the number of processor days remaining in the current On/Off CoD processor enablement period.
  1. Reduce either the number of processors and/or the number of days by amounts such that the product of these two values is less than or equal to the number of processor days remaining in the current On/Off CoD processor enablement period.
  2. Alternatively, you might obtain another On/Off CoD processor enablement code to extend your On/Off CoD processor enablement period.
902B The On/Off CoD processor activation request cannot be accepted because On/Off CoD processors are currently activated. The Current On/Off CoD processors must be deactivated before a new On/Off CoD processor activation request can be accepted. On/Off CoD processors are already activated.
  1. Deactivate current On/Off CoD processors.
  2. Retry the operation.
9031 On/Off CoD processors are not currently enabled on the managed system. An On/Off processor enablement code must be obtained and entered before On/Off CoD processors can be activated. On/Off CoD processors are not currently enabled on the system. Obtain an On/Off CoD processor enablement code, and then try again to activate the processors after the enablement code has been entered.
9033 The On/Off CoD processor deactivation request cannot be accepted because there are no On/Off CoD processors that are currently activated on the managed system. An attempt was made to deactivate processors that have not been activated; therefore, there is no recovery action.
9035 The On/Off CoD processors cannot be deactivated because they cannot be reclaimed by the managed system. Make processors available to be reclaimed by removing them from partitions, and then try again. An attempt was made to deactivate On/Off CoD processors when there are not enough available processors for the system to reclaim.
  1. Deallocate the processors by checking the number of available processors and removing processors from partitions, if necessary, until the number available is equal to or greater than the number of processors that have been activated for On/Off CoD. Either use dynamic partitioning to remove the On/Off processors from a running partition, or shutdown and delete the partition to free up the processors.
  2. Retry the operation.
903D The Reserve CoD processor activation request cannot be accepted because On/Off CoD processors are currently activated. Either wait until the On/Off CoD processor request expires, or cancel the current On/Off processor activation request. Then retry the Reserve CoD processor activation request.
  1. Either wait until the On/Off CoD processor request expires, or cancel the current On/Off processor activation request.
  2. Then retry the Reserve CoD processor activation request.
903E The On/Off CoD processor activation request cannot be accepted because Reserve CoD processors are currently activated. The Reserve CoD processors must be deactivated before an On/Off CoD processor activation request can be accepted. The Reserve CoD processors must be deactivated before an On/Off CoD processor activation request can be accepted.
903F The Reserve CoD processor activation request cannot be accepted because Trial CoD processors are currently activated. Either wait until the Trial CoD activation period expires, or stop the current trial. Then retry the Reserve CoD processor activation request. Either wait until the Trial CoD activation period expires, or stop the current trial. Then retry the Reserve CoD processor activation request.
9040 The number of CoD processors requested exceeds the number of inactive processors that are currently available on the managed system. Reduce the number of processors and try again. Reduce the number of processors and try the operation again.
9041 There are not enough processor days remaining to accept the Reserve CoD processor activation request. Either reduce the number of processors requested or obtain and enter an additional Reserve CoD processor enablement code. Either reduce the number of processors requested, or obtain and enter an additional Reserve CoD processor enablement code.
9042 The Reserve CoD activation request cannot be accepted because Reserve CoD for processors is currently not enabled on the managed system. A Reserve processor enablement code must be obtained and entered before Reserve CoD processors can be activated. A Reserve processor enablement code must be obtained and entered before Reserve CoD processors can be activated. Enter a Reserve processor enablement code, and then try the operation again.
9043 The Reserve CoD deactivation request cannot be accepted because there are no Reserve CoD processors currently activated on the managed system. Reserve CoD processors need to be activated before a deactivation request can be accepted.
9044 {0} There are not enough inactive processors available to accept this CoD code because Reserve CoD processors are currently activated. To make the processors available to be reclaimed by the system, deactivate Reserve CoD processors. Then re-enter the CUoD processor activation code. To make the processors available to be reclaimed by the system, deactivate Reserve CoD processors. Then re-enter the CUoD processor activation code.
9045 {0} There are not enough inactive processors available to accept this CoD code because Reserve CoD processors are currently activated. To make the processors available to be reclaimed by the system, deactivate the Reserve CoD processors. Then re-enter the Trial CoD processor activation code. To make the processors available to be reclaimed by the system, deactivate the Reserve CoD processors. Then re-enter the Trial CoD processor activation code.
9046 {0} The On/Off processor enablement code cannot be accepted because Reserve CoD processors are currently activated. The Reserve CoD processors must be deactivated before an On/Off CoD processor enablement code can be accepted. The Reserve CoD processors must be deactivated before an On/Off CoD processor enablement code can be accepted. Deactivate the Reserve CoD processors, and try the operation again.
9047 {0} The Reserve processor enablement code cannot be accepted because On/Off CoD processors are currently activated. The On/Off CoD processors must be deactivated before a Reserve CoD processor enablement code can be accepted. The On/Off CoD processors must be deactivated before a Reserve CoD processor enablement code can be accepted. Deactivate the On/Off CoD processors, and try the operation again.