HSCL Axxx

This section lists the HSCL Axxx error codes.

Note: The following error messages and recovery actions might include procedures that are not available on the DS8000® management console. If in doubt, contact the next level of support. If you are instructed to shut down the management console, then you must first verify that the customer is not currently performing DS8000 actions through the management console ESSNI connection.
Table 1. HSCL Axxx error codes
Error code Message Recovery action
A00 This operation is not allowed because activation of Virtualization Engine Technologies are not supported on the managed system. Virtualization Engine Technologies activations are not supported on the managed system. If this is incorrect, contact your software representative.
A001 The Show Code Information operation failed. Try the operation again. Try the operation again. If the problem persists, contact your software representative.
A002 The Enter Activation Code operation failed. Try the operation again. Try the operation again. If the problem persists, contact your software representative.
A003 You did not enter the activation code correctly. Try again. Try to enter the activation code again ensuring that it is correct. If you are certain that you entered the correct activation code, contact your Virtualization Engine systems technologies administrator.
A004 {0}The sequence number of the activation code indicates that this code has been used before. Obtain a new activation code and try again. Obtain a new activation code and try the operation again. If the problem persists, contact your Virtualization Engine systems technologies administrator.
A005 {0}The capability for which the activation code was generated is not supported on the managed system. The activation code that was entered is for a capability that is not supported on the managed system.
  1. Obtain a new activation code and try the operation again.
  2. If the problem persists, contact your Virtualization Engine systems technologies administrator.
A006 [0}The operation failed on the managed system. Try the operation again. If the failure persists, contact your hardware service representative. Try the operation again. If the failure persists, contact your hardware service provider.
A007 {0}The activation code was rejected by the managed system because too many incorrect activation codes have been entered. The managed system must be restarted before another activation code will be accepted. Restart the managed system, and retry the operation.
A008 The activation code entered is a CoD activation code instead of a Virtualization Engine Technologies activation code. Try again.
  1. Make sure to obtain a Virtualization Engine Technologies activation code for this system.
  2. Try the operation again.
  3. If the problem persists, contact your Virtualization Engine systems technologies administrator.
A009 The activation code was rejected by the managed system because it is not valid. Contact your Virtualization Engine Technologies administrator. If the problem persists, contact your Virtualization Engine systems technologies administrator.
A00A The activation code is the wrong length. The code entered must be exactly {0} characters long. Try again.
  1. Make sure that your activation code is correct, and is exactly 34 characters in length.
  2. Try the operation again.
  3. If the problem persists, contact your Virtualization Engine systems technologies administrator.
A00B Unknown code information format. Try the operation again. Try the operation again. You might need to upgrade to a newer management console level to fix this problem. If the problem persists, contact your service provider.
A101 The bulk power assembly that was specified as the target is not valid. Verify the bulk power assembly name and try the request again.
  1. Rebuild the managed frame. See MAP6620 Rebuilding managed system information for details.
  2. Try the task again.
  3. If the problem persists, contact your service provider.