Management enclosure location codes (Model 983)
Use Table 1 to find the management
enclosure location code information. For part numbers, see Rack power and cooling part numbers,
Models 983.
| Part | See |
|---|---|
| Management enclosure locations | Figure 1 |
| 8-port Ethernet switches | Figure 1 |
| Fans | Figure 1 |
| Local remote switch card | Figure 1, Figure 2 |
| Management enclosure external connections (rear) | Figure 3 |
| Management enclosure power supplies | Figure 1, Figure 4 |
| RPC card locations (front) | Figure 5 |
| RPC card locations (rear) | Figure 6 |

| Location code | Part name |
|---|---|
| U2nnn.mmm.sssssss-A1 | Fan |
| U2nnn.mmm.sssssss-A2 | Fan |
| U2nnn.mmm.sssssss-C1 | RPC card |
| U2nnn.mmm.sssssss-C2 | RPC card |
| U2nnn.mmm.sssssss-C6 | Local remote switch card |
| U2nnn.mmm.sssssss-E31 | Management enclosure power supply |
| U2nnn.mmm.sssssss-E32 | Management enclosure power supply |
| U2nnn.mmm.sssssss-SW1 | Ethernet switch |
| U2nnn.mmm.sssssss-SW2 | Ethernet switch |
Local remote switch card locations

| Location code | Part name | Connector |
|---|---|---|
| U2nnn.mmm.sssssss-C6 | Local remote switch card | |
| U2nnn.mmm.sssssss-C6-J2 | To RPC card C1 | |
| U2nnn.mmm.sssssss-C6-J3 | To RPC card C2 | |
| U2nnn.mmm.sssssss-C6-J4 | To front LED indicator panel |
Management enclosure external connections (rear)
Management enclosure power supply

| Location code | Part name | Connector |
|---|---|---|
| U2nnn.mmm.sssssss-E3x | Management enclosure power supply | |
| U2nnn.mmm.sssssss-E3x-J1 | To RPC card C1 | |
| U2nnn.mmm.sssssss-E3x-J2 | To RPC card C2 | |
| U2nnn.mmm.sssssss-E3x-J3 | To maintenance consoles, fans, switches | |
| U2nnn.mmm.sssssss-E3x-J4 | To UPS |
RPC card locations

| Location code | Part name | Connector |
|---|---|---|
| U2nnn.mmm.sssssss-C1 | RPC card (left, facing rear) | |
| U2nnn.mmm.sssssss-C2 | RPC card (right, facing rear) | |
| U2nnn.mmm.sssssss-Cx-J1 | To other RPC card | |
| U2nnn.mmm.sssssss-Cx-J2 | To both management enclosure power supplies | |
| U2nnn.mmm.sssssss-Cx-J3 | To local remote switch card | |
| U2nnn.mmm.sssssss-Cx-J201 | Not used | |
| U2nnn.mmm.sssssss-Cx-J202 | Not used | |
| U2nnn.mmm.sssssss-Cx-J203 | To CEC LPAR upper (serial interface) | |
| U2nnn.mmm.sssssss-Cx-J204 | To CEC FSP upper (I2C interface) | |
| U2nnn.mmm.sssssss-Cx-J205 | To CEC LPAR lower (serial interface) | |
| U2nnn.mmm.sssssss-Cx-J206 | To CEC FSP lower (I2C interface) | |
| U2nnn.mmm.sssssss-Cx-J207 | To UPS, Rack-1 | |
| U2nnn.mmm.sssssss-Cx-J208 | To I/O enclosure (2U), I/O module 1 |