MAP3290 DA card repair successful, cable check detected the partner DA card is not found

Use this MAP to determine the partner DA card location.

MAP3290 Section-1

About this task

DA cards work in pairs to provide redundant access through the FC-AL cable to the storage enclosures. The repair of the first DA card was successful. During the FRU verification cable check routine the DA card was not found.

Procedure

  1. The physical location code of the partner DA card is listed in the FRU list of the serviceable event that sent you here. Display open serviceable events.
  2. Repair the serviceable event that lists the partner DA card in its FRU list.
  3. Exit this procedure.