SIRGCFG

This is an unexpected error for this machine type. You should first resolve any other serviceable events on this machine and if this problem persists, you should then call your next level of support.

What to do next

This ends the procedure.

Support Information

About this task

The following is the information from the eServer™ product on which this machine is based. This information might be of use to your support engineer.

Note: This is background information for support use only. It is not necessarily applicable to this machine.

An invalid configuration was detected on an HSL/RIO loop during IPL.

The four rightmost characters of word 4 in the reference code represent the Program Return Code (PRC), which describes the problem detected. The four leftmost digits of word 7 represent the loop number in hexadecimal format.

Procedure

  1. Convert the loop number to decimal format before comparing it to loop numbers shown in serviceable event views and service tools.
  2. To determine the problem, find the PRC in Table 1.
    Note: The FRU description in the serviceable event view might already contain a message that identifies the problem.
    Table 1. Correcting an invalid configuration on an HSL/RIO loop
    PRC Problem identified Corrective action
    xxxx0008 System serial number not set Set the serial number on the system unit. See MAP6F00 Accessing the ASMI. If the problem persists, call your next level of support.
    xxxx3200 Clustered system(s) on loop with SPD migrated tower Migration towers are not supported; remove them.
    xxxx3201 Clustered systems on multiple HSL/RIO loops Ensure all clustered systems are on the same HSL/RIO loop.
    xxxx3202 Multiple SPD migrated towers detected Migration towers are not supported; remove them.
    xxxx3207 SPD migrated tower not on first HSL/RIO loop Migration towers are not supported; remove them.
    xxxx3212 NIC/RIO controller level does not support OptiConnect The NIC/RIO controller hardware component does not support i5/OS HSL OptiConnect. The FRU containing the NIC/RIO controller component must be upgraded to a level that supports HSL OptiConnect. Examine the Service Action Log (SAL) of the IBM® eServer i5 system on this loop for the same error. The SAL will call out the correct FRU to replace. Use the service tools and information for that system to correct the problem and close the problem on this system.

What to do next

This ends the procedure.