RIOIP55
There is an open RIO/HSL loop at IPL time.
RIOIP55 Section-1
About this task
Procedure
- Look in the informational logs for a B7006985 occurring on the same RIO/HSL loop with a value of xxxx3206 or xxxx3208 in word 4. These indicate that a retry attempt was successful and the permanent B7006985 errors for that loop can be closed with no further action necessary.
- If there is a clustered system on the RIO/HSL loop that has not finished it's IPL at the time of the error, you should check for a similar error on that system. These errors will occur until all systems on the loop have been completed their IPL. If there is a similar error on the last system to complete its IPL, work the error from that system. Otherwise you can close this error.
- Check cable seating for the cable indicated in the locations given in the serviceable event view. If no locations are given, check the RIO/HSL Loop Status in the view on the operating system or on the HMC. Find the failed link and check cable connections there. If the cable is an optical cable, use OPT_CLN for direction on cleaning the optical connections.
- If the error persists after steps 1 and 2 above, continue working the error with the FRUs given in the serviceable event view or service documentation. This ends the procedure.