(A1xxxxxx) Service processor reference (attention) codes
An A1xxxxxx system reference code (SRC) is an attention code posted by the service processor. An A1xxxxxx SRC offers information about a platform or service processor dump, confirms a control panel function request, or indicates an issue with a service processor wake-on-LAN setting.
The A1xxxxxx table uses the following format:
- The first column, SRC, contains numbers that identify a particular action your server performs during initialization of firmware.
- The second column, Description/Action, offers a brief description about this SRC. It might also contain instructions for continuing the problem analysis.
- The third column, Failing item, offers a link to service actions for recovering from a hang on an attention code. Click the failing item code only when you experience a hang condition on an attention code. For example, a hang condition occurs when your server performs a requested action but the SRC in the control panel display does not change for several minutes and the service processor appears to be hung.
- The SRCs on this page are from the Power Systems hardware documentation, and the Descriptions apply to a single CEC enclosure or I/O enclosure. The Action and Failing Item fields are modified as appropriate for DS8000® architecture and repair methods.
- SRCs missing from the following tables might be found on the Power Systems online documentation. You can use the SRC description
as is
to define the problem. Do not use the Action and Failing Item without contacting the next level of support first. - To display the Power Systems hardware
online documentation, go to the Web site http://www-01.ibm.com/support/knowledgecenter/.
- In the IBM Systems Hardware Information right content pane, click POWER6 reference codes listing.
| SRC | Description/Action | Failing item |
|---|---|---|
| A1003000 | Platform dump was successful. | FSPSPD1 |
| A1003001 | Reserved (for platform dump). | FSPSPD1 |
| A1003022 | Confirm partition dump (control [operator] panel
function 22). The control panel displays this attention code after you request a partition dump (panel function 22). When you see this code, on the panel, scroll to function 22 again and press Enter to perform the partition dump. |
FSPSPD1 |
| A1003042 | Confirm platform dump (control panel function 42). The control panel displays this attention code after you request a platform dump (panel function 42). When you see this code, on the panel, scroll to function 42 again and press Enter to perform the platform dump. |
FSPSPD1 |
| A1003043 | Confirm service processor dump (control panel function
43). The control panel displays this attention code after a service processor dump (panel function 43) is requested. When you see this code, scroll to function 43 again on the panel and press Enter to perform the service processor dump. |
FSPSPD1 |
| A1008008 | Confirm fast power-off (control panel function 08). This attention code is displayed on the control panel after you request a fast power-off (panel function 08). When you see this code, on the panel, scroll to function 08 again and press Enter to perform the fast power-off. |
FSPSPD1 |
| A1008009 | Beginning emergency power-off (EPO) countdown. | FSPSPD1 |
| A100800A | Proceeding with EPO. This SRC displays after the countdown has completed successfully.
|
FSPSPD1 |
| A1A3C100 | Invalid operational mode for remote power-on (wake on LAN). Check the service processor settings for remote power-on. |