(A1xxxxxx) Service processor reference (attention) codes

An A1xxxxxx system reference code (SRC) is an attention code posted by the service processor. An A1xxxxxx SRC offers information about a platform or service processor dump, confirms a control panel function request, or indicates an issue with a service processor wake-on-LAN setting.

The A1xxxxxx table uses the following format:

  • The first column, SRC, contains numbers that identify a particular action your server performs during initialization of firmware.
  • The second column, Description/Action, offers a brief description about this SRC. It might also contain instructions for continuing the problem analysis.
  • The third column, Failing item, offers a link to service actions for recovering from a hang on an attention code. Click the failing item code only when you experience a hang condition on an attention code. For example, a hang condition occurs when your server performs a requested action but the SRC in the control panel display does not change for several minutes and the service processor appears to be hung.
If you do not find an SRC in the table that follows, contact your next level of support for assistance.
Notes:
  1. The SRCs on this page are from the Power Systems hardware documentation, and the Descriptions apply to a single CEC enclosure or I/O enclosure. The Action and Failing Item fields are modified as appropriate for DS8000® architecture and repair methods.
  2. SRCs missing from the following tables might be found on the Power Systems online documentation. You can use the SRC description as is to define the problem. Do not use the Action and Failing Item without contacting the next level of support first.
  3. To display the Power Systems hardware online documentation, go to the Web site http://www-01.ibm.com/support/knowledgecenter/.
    • In the IBM Systems Hardware Information right content pane, click POWER6 reference codes listing.
Table 1. A1xxxxxx service processor reference codes
SRC Description/Action Failing item
A1003000 Platform dump was successful. FSPSPD1
A1003001 Reserved (for platform dump). FSPSPD1
A1003022 Confirm partition dump (control [operator] panel function 22).

The control panel displays this attention code after you request a partition dump (panel function 22). When you see this code, on the panel, scroll to function 22 again and press Enter to perform the partition dump.

FSPSPD1
A1003042 Confirm platform dump (control panel function 42).

The control panel displays this attention code after you request a platform dump (panel function 42). When you see this code, on the panel, scroll to function 42 again and press Enter to perform the platform dump.

FSPSPD1
A1003043 Confirm service processor dump (control panel function 43).

The control panel displays this attention code after a service processor dump (panel function 43) is requested. When you see this code, scroll to function 43 again on the panel and press Enter to perform the service processor dump.

FSPSPD1
A1008008 Confirm fast power-off (control panel function 08).

This attention code is displayed on the control panel after you request a fast power-off (panel function 08). When you see this code, on the panel, scroll to function 08 again and press Enter to perform the fast power-off.

FSPSPD1
A1008009 Beginning emergency power-off (EPO) countdown. FSPSPD1
A100800A Proceeding with EPO.
This SRC displays after the countdown has completed successfully.
FSPSPD1
A1A3C100 Invalid operational mode for remote power-on (wake on LAN).

Check the service processor settings for remote power-on.