| BE820100 |
I2C bus 0 hung. |
| BE820101 |
I2C bus 1 hung. |
| BE820102 |
I2C bus 2 hung. |
| BE820103 |
I2C bus 3 hung. |
| BE820104 |
I2C bus 4 hung. |
| BE820105 |
I2C bus 5 hung. |
| BE820106 |
I2C bus 6 hung. |
| BE820107 |
I2C bus 7 hung. |
| BE82010F |
Fan controller 1 I2C bus received NACK. |
| BE820110 |
Fan controller 2 I2C bus received NACK. |
| BE820114 |
Local expander monitoring component (420) has reported an
error. |
| BE820115 |
Opposite Expander I2C bus received NACK. |
| BE820116 |
Alternate expander monitoring component (420) has reported an
error. |
| BE82011B |
Fan 0 is not present or has low RPM. |
| BE82011C |
Fan 1 is not present or has low RPM. |
| BE82011D |
Fan 2 is not present or has low RPM. |
| BE82011E |
Fan 3 is not present or has low RPM. |
| BE820122 |
RAID processor on RAID controller C1 temperature
sensor read failure. |
| BE820126 |
PPC on RAID controller C1 temperature sensor
read failure. |
| BE82012A |
Expander on RAID controller C1 temperature sensor
read failure. |
| BE82012E |
Ambient 1 on RAID controller C1 temperature
sensor read failure. |
| BE820132 |
Ambient 2 on RAID controller C1 temperature
sensor read failure. |
| BE820136 |
Power supply 1 on RAID controller C1 temperature
sensor read failure. |
| BE82013A |
Power supply 2 on RAID controller C1 temperature
sensor read failure. |
| BE82013E |
RAID processor on RAID controller C2 temperature
sensor read failure. |
| BE820142 |
PPC on RAID controller C2 temperature sensor
read failure. |
| BE820146 |
Expander on RAID controller C2 temperature sensor
read failure. |
| BE82014A |
Ambient 1 on RAID controller C2 temperature
sensor read failure. |
| BE82014E |
Ambient 2 on RAID controller C2 temperature
sensor read failure. |
| BE820152 |
Power supply 1 on RAID controller C2 temperature
sensor read failure. |
| BE820156 |
Power supply 2 on RAID controller C2 temperature
sensor read failure. |
| BE820160 |
Loss of power on both power supplies. |
| BE820161 |
Power Supply 1 VPD data error, checksum or corruption. |
| BE820162 |
Power Supply 1 no response on I2C interface. |
| BE820163 |
Power supply unit (PSU) 1 missing. |
| BE820165 |
Power Supply 1 fan fault. |
| BE820166 |
Power Supply 1 thermal fault. |
| BE820167 |
Power supply unit (PSU) 1, DC over voltage. |
| BE820168 |
Power supply unit (PSU) 1, DC under voltage. |
| BE820169 |
Power supply unit (PSU) 1, DC over current. |
| BE820170 |
Power supply unit (PSU) 2 missing. |
| BE82016A |
VCO unit 1, DC under voltage. |
| BE82016B |
Power Supply 1 current share warning. |
| BE82016C |
Power supply unit (PSU) 1, DC fail. |
| BE82016E |
Power Supply 2 VPD data error, checksum or corruption. |
| BE82016F |
Power Supply 2 no response on I2C interface. |
| BE820172 |
Power Supply 2 fan fault. |
| BE820173 |
Power Supply 2 thermal fault. |
| BE820174 |
Power supply unit (PSU) 2, DC over voltage. |
| BE820175 |
Power supply unit (PSU) 2, DC under voltage. |
| BE820176 |
Power supply unit (PSU) 2, DC over current. |
| BE820177 |
VCO unit 2, DC under voltage. |
| BE820178 |
Power Supply 2 current share warning. |
| BE820179 |
Power supply unit (PSU) 2, DC fail. |
| BE820180 |
Only RAID controller C1 received PCIe power
down request. |
| BE820181 |
Unexpected firmware trap. |
| BE820183 |
Watchdog timer trip. |
| BE820186 |
Power supply unit (PSU) 1, AC fail. |
| BE820187 |
Power supply unit (PSU) 2, AC fail. |
| BE820188 |
Only RAID controller C2 received PCIe power
down request. |
| BE820189 |
Storage enclosure statesave complete. |
| BE82018A |
Storage enclosure statesave threshold exceeded. |
| BE820200 |
ESM VPD checksum failed. |
| BE820201 |
Midplane VPD checksum failed. |
| BE820202 |
Feature code check failed. |
| BE820203 |
VPD migration failed. |
| BE820204 |
I2C check failed. |
| BE820205 |
Power supply failed. |
| BE820206 |
Hot plug controller check failed. |
| BE820207 |
Regulator test failed. |
| BE820208 |
Fan test failed. |
| BE820209 |
Expander clock failed. |
| BE82020A |
Internal RAM check failed. |
| BE82020B |
ESM VPD check failed. |
| BE82020C |
Midplane VPD check failed. |
| BE82020D |
I2C check failed. |
| BE82020E |
PCI Repeaters check failed. |
| BE82020F |
SAS Repeaters check failed. |
| BE820210 |
PSoc SGPIO failed. |
| BE820272 |
Over temperature, warning threshold exceeded. |
| BE820296 |
Over temperature, critical threshold exceeded. |
| BE820300 |
PHY Link not ready. |
| BE820301 |
PHY Adapt Timer expired. |
| BE820302 |
PHY Link not stable. |
| BE82CD01 |
Power supply unit (PSU) 1, DC over voltage. |
| BE82CD02 |
Power supply unit (PSU) 1, DC under voltage. |
| BE82CD03 |
Power supply unit (PSU) 1, DC over current. |
| BE82CD05 |
Power supply unit (PSU) 1 powered off unexpectedly. |
| BE82CD07 |
Power supply unit (PSU) 1, AC fail. |
| BE82CD08 |
Power supply unit (PSU) 1, DC fail. |
| BE82CD09 |
Power supply unit (PSU) 1, fan 1 failure. |
| BE82CD0A |
Power supply unit (PSU) 1, fan 2 failure. |
| BE82CD0B |
Power supply unit (PSU) 1, fan 3 failure. |
| BE82CD0C |
Power supply unit (PSU) 1, fan 4 failure. |
| BE82CD0D |
Power supply unit (PSU) 1, fan 5 failure. |
| BE82CD0E |
Power supply unit (PSU) 1, fan 6 failure. |
| BE82CD0F |
Power supply unit (PSU) 1, fan 7 failure. |
| BE82CD10 |
Power supply unit (PSU) 1, fan 8 failure. |
| BE82CD11 |
Power supply unit (PSU) 2, DC over voltage. |
| BE82CD12 |
Power supply unit (PSU) 2, DC under voltage. |
| BE82CD13 |
Power supply unit (PSU) 2, DC over current. |
| BE82CD15 |
Power supply unit (PSU) 2 powered off unexpectedly. |
| BE82CD17 |
Power supply unit (PSU) 2, AC fail. |
| BE82CD18 |
Power supply unit (PSU) 2, DC fail. |
| BE82CD19 |
Power supply unit (PSU) 2, fan 1 failure. |
| BE82CD1A |
Power supply unit (PSU) 2, fan 2 failure. |
| BE82CD1B |
Power supply unit (PSU) 2, fan 3 failure. |
| BE82CD1C |
Power supply unit (PSU) 2, fan 4 failure. |
| BE82CD1D |
Power supply unit (PSU) 2, fan 5 failure. |
| BE82CD1E |
Power supply unit (PSU) 2, fan 6 failure. |
| BE82CD1F |
Power supply unit (PSU) 2, fan 7 failure. |
| BE82CD20 |
Power supply unit (PSU) 2, fan 8 failure. |
| BE82CD21 |
Over temperature, warning threshold exceeded. |
| BE82CD22 |
Over temperature, critical threshold exceeded. |
| BE82CD23 |
Under temperature, warning threshold exceeded. |
| BE82CD24 |
Under temperature, critical threshold exceeded. |
| BE82CD4D |
Intra enclosure services manager (ESM) communication fails on both paths. |
| BE82CD4E |
Enclosure services manager (ESM) VPD read failure. |
| BE82CD4F |
Miscompare detected between enclosure midplane VPD and enclosure services manager (ESM) VPD. |
| BE82CD50 |
Intra enclosure services manager (ESM)communication fails on both paths. |
| BE82CD51 |
Enclosure services manager(ESM)VPD read failure. |
| BE82CD52 |
Miscompare detected between enclosure midplane VPD and enclosure services manager (ESM) VPD. |
| BE82CD55 |
Enclosure services manager (ESM) 1 voltage sensor reading above/below thresholds - (3.3v OV) |
| BE82CD56 |
Enclosure services manager (ESM) 1 voltage sensor reading above/below thresholds - (3.3v UV) |
| BE82CD59 |
Enclosure services manager (ESM) 1 voltage sensor reading above/below thresholds - (1.0v OV) |
| BE82CD5A |
Enclosure services manager (ESM) 1 voltage sensor reading above/below thresholds - (1.0v UV) |
| BE82CD5D |
Enclosure services manager (ESM) 1 voltage sensor reading above/below thresholds - (1.8v OV) |
| BE82CD5E |
Enclosure services manager (ESM) 1 voltage sensor reading above/below thresholds - (1.8v UV) |
| BE82CD61 |
Enclosure services manager (ESM) 1 voltage sensor reading above/below thresholds - (0.92v OV) |
| BE82CD62 |
Enclosure services manager (ESM) 1 voltage sensor reading above/below thresholds - (0.92v UV) |
| BE82CD65 |
Enclosure services manager (ESM) 2 voltage sensor reading above/below thresholds - (3.3v OV) |
| BE82CD66 |
Enclosure services manager (ESM) 2 voltage sensor reading above/below thresholds - (3.3v UV) |
| BE82CD69 |
Enclosure services manager (ESM) 2 voltage sensor reading above/below thresholds - (1.0v OV) |
| BE82CD6A |
Enclosure services manager (ESM) 2 voltage sensor reading above/below thresholds - (1.0v UV) |
| BE82CD6D |
Enclosure services manager (ESM) 2 voltage sensor reading above/below thresholds - (1.8v OV) |
| BE82CD6E |
Enclosure services manager (ESM) 2 voltage sensor reading above/below thresholds - (1.8v UV) |
| BE82CD71 |
Enclosure services manager (ESM) 2 voltage sensor reading above/below thresholds - (0.92v OV) |
| BE82CD72 |
Enclosure services manager (ESM) 2 voltage sensor reading above/below thresholds - (0.92v UV) |
| BE82CD73 |
Enclosure services manager (ESM) 1 failure to read enclosure midplane VPD 1. |
| BE82CD74 |
Enclosure services manager (ESM) 2 failure to read enclosure midplane VPD 1. |
| BE82CD75 |
Enclosure services manager (ESM) 1 failure to read enclosure midplane VPD 2. |
| BE82CD76 |
Enclosure services manager (ESM) 2 failure to read enclosure midplane VPD 2. |
| BE82CD77 |
Complex Programmable Logic Device (CPLD) failure on enclosure services manager (ESM) 1 |
| BE82CD78 |
Complex Programmable Logic Device (CPLD) failure on enclosure services manager (ESM) 2 |
| BE82CD79 |
Degraded SAS link reported on port T1 of enclosure services manager (ESM) 1. |
| BE82CD7A |
Degraded SAS link reported on port T2 of enclosure services manager (ESM) 1. |
| BE82CD7B |
Degraded SAS link reported on port T3 of enclosure services manager (ESM) 1. |
| BE82CD7C |
Degraded SAS link reported on port T1 of enclosure services manager (ESM) 2. |
| BE82CD7D |
Degraded SAS link reported on port T2 of enclosure services manager (ESM) 2. |
| BE82CD7E |
Degraded SAS link reported on port T3 of enclosure services manager (ESM) 2. |
| BE82CD80 |
Enclosure services manager (ESM) 1 reports communication failure with power
supply unit (PSU) 1. |
| BE82CD81 |
Enclosure services manager (ESM) 2 reports communication failure with power
supply unit (PSU) 1. |
| BE82CD82 |
Enclosure services manager (ESM) 1 reports communication failure with power
supply unit (PSU) 2. |
| BE82CD83 |
Enclosure services manager (ESM) 2 reports communication failure with power
supply unit (PSU) 2. |