BEBxxxxx

This section lists the BEBxxxxx system reference codes.

If the SRC listed in a serviceable event is missing from the following table, ask your next level of support for assistance.
Note: Next level, inform development of any SRCs not defined in the table.
Table 1. BEB0xxxx System Reference Codes
System Reference Code Description
BEB00010 On-Demand Data Collection (General PE package).
BEB00011 Moved un-selected General PE pkg OR Customer UI pkg files to Virtual Retain.
BEB00012 Individual file offload(HMC/LPAR)
BEB00013 On-Demand Data Collection (PE Package by Area/Condition)
BEB00014 On-Demand Data Collection (Customer User Interface data package)
BEB00018 Automatic Data Collection (General PE package).
BEB00019 Weekly Data Collection (General PE package).
BEB00020 End-to-End Communication Test
BEB00030 PDISK/DDM statesave without automatically sending call home data.
BEB00031 Enclosure statesave without automatically sending call home data.
BEB00032 CPSS statesave without automatically sending call home data.
BEB00033 ISS DA statesave without automatically sending call home data.
BEB00034 All data packages including Customer UI data and General PE packages.
BEB00035 ODD dump without automatically sending call home data.
BEB00036 Lightweight ODD dump without automatically sending call home data.
Table 2. BEB1xxxx System Reference Codes
System Reference Code Description
BEB10010 Network Surveillance NIC_FAILURE: Single HMC physical link unavailable on Ethernet port eth0 or eth3. The network is unknown.
BEB10011 Network Surveillance NIC_FAILURE: Single HMC physical link unavailable on ethernet port - eth0 (172.16-BLACK network)1
BEB10012 Network Surveillance NIC_FAILURE: Single HMC physical link unavailable on ethernet port - eth3 (172.17-GRAY network)1
BEB10013 Network Surveillance: Ethernet cables missing or swapped.
BEB10014 Network Surveillance NIC_FAILURE: Single HMC physical link unavailable on Ethernet port - eth0 on the USB adapter (172.16-BLACK network).
BEB10015 Network Surveillance NIC_FAILURE: Single HMC physical link unavailable on Ethernet port - eth3 on the USB adapter (172.17-GRAY network).
BEB10020 Network Surveillance LINK_FSP_HMC: Single HMC lost link to single FSP. The network is unknown.
BEB10021 Network Surveillance LINK_FSP_HMC: Single HMC lost link to single FSP over 172.16-BLACK network1
BEB10022 Network Surveillance LINK_FSP_HMC: Single HMC lost link to single FSP over 172.17-GRAY network1
BEB10030 Network Surveillance LINK_PART_HMC: Single HMC lost link to single partition on a system; both paths are not available.
BEB10040 Network Surveillance LINK_PART_HMC_REDUND: Single HMC lost link to single partition on a system of the two networks, only one is available. The network is unknown.
BEB10041 Network Surveillance LINK_PART_HMC_REDUND: Single HMC lost link to single partition on a system, the path through the 172.16-BLACK network1 is not available, the other network is OK.
BEB10042 Network Surveillance LINK_PART_HMC_REDUND: Single HMC lost link to single partition on a system, the path through the 172.17-GRAY network1 is not available, the other network is OK.
BEB10050 Network Surveillance LINK_M_PART_HMC: Single HMC lost links to multiple partitions on single system; both paths are not available; FSP to HMC link is still working.
BEB10060 Network Surveillance LINK_A_PART_HMC: Single HMC lost links to all partitions on single system; both paths are not available; FSP to HMC link is still working.
BEB10070 Network Surveillance LINK_ALL_HMC: Single HMC lost links to single system (partition and FSP); both paths are not available.
BEB10080 Network Surveillance LINK_HMC_SYS: Single HMC lost links to all systems (FSP and partition); both paths are not available.
BEB10090 HMC to service processor function communication might have been interrupted.
BEB10100 Network Surveillance LINK_HMC_HMC: Lost HMC to HMC links; both paths are not available.
BEB10110 Network Surveillance LINK_HMC_HMC_REDUND
BEB10120 Network Surveillance LINK_HMC_M_HMC: Lost single HMC to HMC link; only one path is not available.
BEB10130 Network Surveillance LINK_HMC_ALL: Lost HMC link to multiple HMC's; both paths are not available (n/a for MM)
BEB10140 Network Surveillance M_LINK_HMC_SYS: Multiple HMCs lost all links to a single system (FSP and partition)
BEB10150 Network Surveillance M_LINK_HMC_M_SYS: Multiple HMCs lost all links to multiple systems (FSP and partition)
BEB10160 Network Surveillance M_LINK_HMC_ALL: Multiple HMCs lost all links to all systems (FSP and partition)
BEB10200 Ethernet port failure detected.
BEB10301 Network Surveillance: Ethernet switch SW1 (Black network) failed.
BEB10302 Network Surveillance: Ethernet switch SW2 (Gray network) failed.
1 - The default address range is shown, but the customer might have selected to use one of three optional address ranges. To find out which address range was selected, see MAP7005 Determining which private network address range is selected.
Table 3. BEB2xxxx System Reference Codes
System Reference Code Description
BEB20010 Call Home Test.
BEB20011 Informational Message - Customer notification and call home of warmstart recovery process.
BEB20012 On Demand Data dump initiated by DS8000 Microcode.
BEB20013 Informational Message - Customer notification and call home of quickstart recovery process.
BEB20014 Informational Message - Customer notification and call home of warmstart recovery process due to hardware event.
BEB20015 Informational Message - Customer notification and call home of warmstart recovery process due to data collection event.
BEB20016 Informational Message - Customer notification and call home of warmstart recovery process due to microcode event.
BEB20020 Connection Established.
BEB20021 Secure IBM® service connection established.
BEB20022 Secure IBM service connection dropped.
BEB20030 VPN Call Back Failed.
BEB21000 Backup critical data failed.
BEB21001 LPAR configuration data failed to be backed up.
BEB21002 The management console was rebuilt or transformed (upgraded) after CSM was updated by the customer. To restore configuration backups, the latest Copy Services Manager (CSM) version must be reinstalled on the management console. Required version = version. Installed version = version.
BEB25001 Customer initiated request
Table 4. BEB3xxxx System Reference Codes
System Reference Code Description
BEB30001 HMC health check: HMC FileSystem size check failed.
BEB30002 HMC health check: ESSNI Server state check failed.
BEB30003 HMC health check: DS8000 Storage manager server state check failed.
BEB30004 HMC health check: PHYP SRC check failed.
BEB30005 HMC health check: Verification of HMC Peer Domain failed.
BEB30006 HMC health check: Check to verify if Large file transfer is enabled failed.
BEB30007 HMC health check: HMC management domain verification failed.
BEB30008 HMC health check: Check to verify LPARs running from HMC failed.
BEB30009 HMC health check: Verification of management console memory configuration failed.
BEB30010 HMC health check: Verification of ResourceManagers on LPAR failed.
BEB30011 HMC health check: Verification of RMC objects on LPAR failed.
BEB30012 HMC health check: Verification of storage facility power on/off option failed.
BEB30013 HMC health check: Verification of CPSS availability on LPARs failed.
BEB30014 HMC health check: Verification of power components failed.
BEB30015 HMC health check: Verification of DA load state failed.
BEB30016 HMC health check: Verification of pinned data on LPARs failed.
BEB30017 HMC health check: No disk in HMC DVD drive or DVD write check failed.
BEB30018 HMC health check: logrotate.status file size is 0. Will cause PA failure.
BEB30019 HMC health check: Base system command failed.
BEB30020 HMC health check: Verification of service locks failed.
BEB30021 HMC health check: Verification of HMC Peer Node failed.
BEB30022 HMC health check: Verification of resource managers on HMC failed.
BEB30023 HMC health check: Verification of HMC VPD failed.
BEB30024 HMC health check: Verification of RMC objects(StorageFacility) failed.
BEB30025 HMC health check: Verification of RMC objects(SystemPartition) failed.
BEB30026 HMC health check: Verification of storage facility power off option failed.
BEB30027 HMC health check: Verification of RIO loop failed.
BEB30028 HMC health check: Verification of power supplies failed.
BEB30029 HMC health check: Failed to query HMC laptop external cooling fans status (verifyFanStatus)
BEB30030 HMC health check: Verification of software PID expiration date failed.