(D2xxxxxx) Partition status progress codes
D2xxxxxx SRCs are posted by the Virtual Service Processor (VSP) when powering down a partition.
For use by service providers.
| Progress code | Description/Action (Perform all actions before exchanging failing items) |
Failing items |
|---|---|---|
| D200A100 | Received MSD SP attention. | |
| D200A110 | Received CPM SP attention. | |
| D200A120 | Received LL SP attention. | |
| D200A130 | Received RPA end-of-life event. | |
| D200A200 | Begin partition power down. SRC word 3 contains the
reason for the power off. SRC word 3 power-down reasons
|
|
| D200B050 | Begin transfer slot locks to VSP. | |
| D200B05F | End transfer slot locks to VSP. | |
| D200B060 | Begin transfer VIO slot locks to VSP. | |
| D200B06F | End transfer VIO slot locks to VSP. | |
| D200B070 | Begin reset slots. | |
| D200B077 | Waiting for reset slots. | |
| D200B07F | End reset slots. | |
| D200B080 | Begin reset VIO slots. | |
| D200B08F | End reset VIO slots. | |
| D200B090 | Begin soft POR slots. | |
| D200B097 | Waiting soft POR slots. | |
| D200B09F | End soft POR slots. | |
| D200B100 | Sending Hypervisor reset. | |
| D200B1FF | Hypervisor reset successfully sent. | |
| D200B200 | Begin forced LP reset (after the 1 second timeout). | |
| D200B210 | Send CSP/FSP soft processor reset command (word 3 processor ID, word 4 thread ID). | |
| D200B2FF | End forced LP reset. | |
| D200B300 | Closing Hypervisor events paths. | |
| D200B310 | Deactivating panel functions. | |
| D200B3FF | Hypervisor reset complete successfully. | |
| D200C100 | Sending Hypervisor I/O reset. | |
| D200C1FF | Hypervisor I/O reset sent successfully. | |
| D200C200 | Deallocating events. | |
| D200C2FF | Hypervisor I/O reset complete successfully. | |
| D200D100 | Removing partition configuration resources. | |
| D200D1FF | Partition resources removed successfully. | |
| D200E050 | Begin power off slots. | |
| D200E057 | Waiting power off slots. | |
| D200E05F | End power off slots. | |
| D200E060 | Begin power off VIO slots. | |
| D200E06F | End power off VIO slots. | |
| D200E080 | Begin release slot locks. | |
| D200E08F | End release slot locks. | |
| D200E090 | Begin release VIO slot locks. | |
| D200E09F | End release VIO slot locks. | |
| D200E0A0 | Begin disassociationof serial ports. | |
| D200E0A8 | Disassociate serial ports from an RPA partition. | |
| D200E0AF | End disassociation of serial ports. | |
| D200E100 | Power off SPCN racks. | |
| D200E110 | Issuing a rack power off command. | |
| D200E120 | Rack power off command complete successfully. | |
| D200E1FF | SPCN racks powered off phase complete. |