FC-AL and Flash PCIe / SAS cables – Models 985, 85E (single-phase power)

These tables show the point-to-point connections for FC-AL and Flash PCIe / SAS cables on a Model 985 (single-phase power), with or without expansion racks.
Note:
  • Racks are shown with the maximum number of storage enclosures and device adapter cards. Your rack might contain fewer storage enclosures or device adapter cards.
  • The figures that follow show the maximum number of racks in a storage facility with these rack models.
Figure 1. Point-to-point cabling diagram for storage enclosure FC-AL and Flash PCIe / SAS cables (Models 985, 85E, single-phase power, rear view, racks 1, 2)
Point-to-point cabling diagram for storage enclosure FC-AL and Flash PCIe / SAS cables (Models 985, 85E, single-phase power, rear view, racks 1, 2)
Figure 2. Point-to-point cabling diagram for the FC-AL cables (Models 985, 85E, single-phase power, rear view, racks 3, 4, 5)
Point-to-point cabling diagram for the FC-AL cables (Models 985, 85E, single-phase power, rear view, racks 3, 4, 5)

FC-AL cables

  1. FC-AL cables and connectors are identified with two different color codes and a location designator:
    1. A colored band, corresponding to the color code of the DA pair, is found on each end of the cable near the connector. These color codes are shown in Figure 1 and Figure 2.
    2. The connector itself is color coded to help prevent cross-cabling at the Fibre Channel interface card (FCIC) or device adapter card (DA) end. The connectors always appear in the following order:
      beige (T1), green (T2), black (T3), and blue (T4)	
      as shown in Figure 3 and Figure 4. This color code is specific to each FCIC or DA, and is independent of the DA pair color code.
    3. A black or white label at each end of the cable shows a location designator (for example, 0A2). Both ends of the cable have the same location designator and DA pair color code. However, the connector at each end of the same cable usually does NOT have the same color code.
  2. Location designators are in the form CTP, where:
    C
    Is the device adapter pair (0-7)
    T
    Is the port pair on the device adapter (A, B, C, D, a, b, c, d) (uppercase for left device adapter in pair, lowercase for right device adapter in pair).
    P
    Is the logical position of the downstream FCIC in the loop.
    Example: 2a1 is the link between device adapter R1-XI4-P1-C6-T1 and R1-G07-P1-C1-T2.
    2
    Device adapter pair 2
    a
    First port pair on right adapter of device adapter pair (lowercase a)
    1
    First FCIC on loop of this port pair
    The connector plugged into R1-XI4-P1-C6-T1 (2a1) is beige, while the connector plugged into R1-G07-P1-C1-T2 (2a1) is green.
  3. Some connectors are for cables that would go to an optional expansion rack. In that case, only one instance of that designator is on the rack.
  4. The black and white label at each end may have a physical location code in addition to the location designator.
Figure 3. FC-AL cable connector color codes - Fibre Channel interface card (FCIC) end
FC-AL cable connector color codes - Fibre Channel interface card (FCIC) end
Figure 4. Flash PCIe cable connector color codes - I/O enclosure PCIe and PCN card end (-C7-T5 / -C7-T6)
FC-AL cable connector color codes - device adapter card (DA) end

FC-AL cabling tables

Table 1 and Table 2 show a summary of FC-AL cabling for models 985 and 85E (single-phase power).
Table 3 through Table 6 show details of the FC-AL loops originating with Rack 1 device adapters (device adapter pairs 2, 0, 3, and 1, in normal installation order).
Table 7 through Table 10 show details of the FC-AL loops originating with Rack 2 device adapters (device adapter pairs 6, 4, 7, and 5, in normal installation order).
Note: Location designators are labeled as link in the following tables.
Table 1. FC-AL cabling summary – Rack 1 device adapters (Models 985, 85E single-phase power - Rack-1 Configuration: AE6)

From:

DA Pair

DA

Pair (link)

To:

Storage Enclosure

To:

Storage Enclosure

To:

Storage Enclosure

To:

Storage Enclosure

R1-XI3-P1-C3-T1/T2
R1-XI4-P1-C6-T1/T2
2 (A)
2 (a)
R3-G17 R3-G05 R4-G07 R5-G09
R1-XI3-P1-C3-T3/T4
R1-XI4-P1-C6-T3/T4
2 (B)
2 (b)
R3-G18 R3-G06 R4-G08 R5-G10
R1-XI1-P1-C3-T1/T2
R1-XI2-P1-C6-T1/T2
0 (A)
0 (a)
R1-G05 R3-G15 R3-G03 R4-G05
R1-XI1-P1-C3-T3/T4
R1-XI2-P1-C6-T3/T4
0 (B)
0 (b)
R1-G06 R3-G16 R3-G04 R4-G06
R1-XI3-P1-C6-T1/T2
R1-XI4-P1-C3-T1/T2
3 (A)
3 (a)
R1-G03 R3-G13 R3-G01 R4-G03
R1-XI3-P1-C6-T3/T4
R1-XI4-P1-C3-T3/T4
3 (B)
3 (b)
R1-G04 R3-G14 R3-G02 R4-G04
R1-XI1-P1-C6-T1/T2
R1-XI2-P1-C3-T1/T2
1 (A)
1 (a)
R1-G01 R3-G11 R4-G17 R4-G01
R1-XI1-P1-C6-T3/T4
R1-XI2-P1-C3-T3/T4
1 (B)
1 (b)
R1-G02 R3-G12 R4-G18 R4-G02
Table 2. FC-AL cabling summary – Rack 2 device adapters (Models 985, 85E single-phase - Rack-1 Configuration: AE6)

From:

DA Pair

DA

Pair (link)

To:

Storage Enclosure

To:

Storage Enclosure

To:

Storage Enclosure

To:

Storage Enclosure

R2-XI3-P1-C3-T1/T2
R2-XI4-P1-C6-T1/T2
6 (A)
6 (a)
R2-G03 R4-G15 R5-G17 R5-G07
R2-XI3-P1-C3-T3/T4
R2-XI4-P1-C6-T3/T4
6 (B)
6 (b)
R2-G04 R4-G16 R5-G18 R5-G08
R2-XI1-P1-C3-T1/T2
R2-XI2-P1-C6-T1/T2
4 (A)
4 (a)
R2-G09 R2-G01 R4-G13 R5-G15
R2-XI1-P1-C3-T3/T4
R2-XI2-P1-C6-T3/T4
4 (B)
4 (b)
R2-G10 R2-G02 R4-G14 R5-G16
R2-XI3-P1-C6-T1/T2
R2-XI4-P1-C3-T1/T2
7 (A)
7 (a)
R2-G07 R3-G09 R4-G11 R5-G13
R2-XI3-P1-C6-T3/T4
R2-XI4-P1-C3-T3/T4
7 (B)
7 (b)
R2-G08 R3-G10 R4-G12 R5-G14
R2-XI1-P1-C6-T1/T2
R2-XI2-P1-C3-T1/T2
5 (A)
5 (a)
R2-G05 R3-G07 R4-G09 R5-G11
R2-XI1-P1-C6-T3/T4
R2-XI2-P1-C3-T3/T4
5 (B)
5 (b)
R2-G06 R3-G08 R4-G10 R5-G12
Table 3. FC-AL cabling matrix – DA Pair 2 (Models 985, 85E single-phase power)

From:

DA

Link

To:

FCIC

 

From:

FCIC

Link

To:

FCIC

R1-XI3-P1-C3-T1 2A1 R3-G17-P1-C1-T1   R3-G17-P1-C1-T3 2A3 R3-G05-P1-C1-T1
R1-XI4-P1-C6-T1 2a1 R3-G17-P1-C1-T2   R3-G17-P1-C1-T4 2a3 R3-G05-P1-C1-T2
R1-XI3-P1-C3-T2 2A2 R3-G17-P1-C2-T1   R3-G17-P1-C2-T3 2A4 R3-G05-P1-C2-T1
R1-XI4-P1-C6-T2 2a2 R3-G17-P1-C2-T2   R3-G17-P1-C2-T4 2a4 R3-G05-P1-C2-T2
R1-XI3-P1-C3-T3 2B1 R3-G18-P1-C1-T1   R3-G18-P1-C1-T3 2B3 R3-G06-P1-C1-T1
R1-XI4-P1-C6-T3 2b1 R3-G18-P1-C1-T2   R3-G18-P1-C1-T4 2b3 R3-G06-P1-C1-T2
R1-XI3-P1-C3-T4 2B2 R3-G18-P1-C2-T1   R3-G18-P1-C2-T3 2B4 R3-G06-P1-C2-T1
R1-XI4-P1-C6-T4 2b2 R3-G18-P1-C2-T2   R3-G18-P1-C2-T4 2b4 R3-G06-P1-C2-T2

From:

FCIC

Link

To:

FCIC

 

From:

FCIC

Link

To:

FCIC

R3-G05-P1-C1-T3 2A5 R4-G07-P1-C1-T1   R4-G07-P1-C1-T3 2A7 R5-G09-P1-C1-T1
R3-G05-P1-C1-T4 2a5 R4-G07-P1-C1-T2   R4-G07-P1-C1-T4 2a7 R5-G09-P1-C1-T2
R3-G05-P1-C2-T3 2A6 R4-G07-P1-C2-T1   R4-G07-P1-C2-T3 2A8 R5-G09-P1-C2-T1
R3-G05-P1-C2-T4 2a6 R4-G07-P1-C2-T2   R4-G07-P1-C2-T4 2a8 R5-G09-P1-C2-T2
R3-G06-P1-C1-T3 2B5 R4-G08-P1-C1-T1   R4-G08-P1-C1-T3 2B7 R5-G10-P1-C1-T1
R3-G06-P1-C1-T4 2b5 R4-G08-P1-C1-T2   R4-G08-P1-C1-T4 2b7 R5-G10-P1-C1-T2
R3-G06-P1-C2-T3 2B6 R4-G08-P1-C2-T1   R4-G08-P1-C2-T3 2B8 R5-G10-P1-C2-T1
R3-G06-P1-C2-T4 2b6 R4-G08-P1-C2-T2   R4-G08-P1-C2-T4 2b8 R5-G10-P1-C2-T2
Table 4. FC-AL cabling matrix – DA Pair 0 (Models 985, 85E single-phase power)


From:

DA

Link

To:

FCIC

 

From:

FCIC

Link

To:

FCIC

R1-XI1-P1-C3-T1 0A1 R1-G05-P1-C1-T1   R1-G05-P1-C1-T3 0A3 R3-G15-P1-C1-T1
R1-XI2-P1-C6-T1 0a1 R1-G05-P1-C1-T2   R1-G05-P1-C1-T4 0a3 R3-G15-P1-C1-T2
R1-XI1-P1-C3-T2 0A2 R1-G05-P1-C2-T1   R1-G05-P1-C2-T3 0A4 R3-G15-P1-C2-T1
R1-XI2-P1-C6-T2 0a2 R1-G05-P1-C2-T2   R1-G05-P1-C2-T4 0a4 R3-G15-P1-C2-T2
R1-XI1-P1-C3-T3 0B1 R1-G06-P1-C1-T1   R1-G06-P1-C1-T3 0B3 R3-G16-P1-C1-T1
R1-XI2-P1-C6-T3 0b1 R1-G06-P1-C1-T2   R1-G06-P1-C1-T4 0b3 R3-G16-P1-C1-T2
R1-XI1-P1-C3-T4 0B2 R1-G06-P1-C2-T1   R1-G06-P1-C2-T3 0B4 R3-G16-P1-C2-T1
R1-XI2-P1-C6-T4 0b2 R1-G06-P1-C2-T2   R1-G06-P1-C2-T4 0b4 R3-G16-P1-C2-T2

From:

FCIC

Link

To:

FCIC

 

From:

FCIC

Link

To:

FCIC

R3-G15-P1-C1-T3 0A5 R3-G03-P1-C1-T1   R3-G03-P1-C1-T3 0A7 R4-G05-P1-C1-T1
R3-G15-P1-C1-T4 0a5 R3-G03-P1-C1-T2   R3-G03-P1-C1-T4 0a7 R4-G05-P1-C1-T2
R3-G15-P1-C2-T3 0A6 R3-G03-P1-C2-T1   R3-G03-P1-C2-T3 0A8 R4-G05-P1-C2-T1
R3-G15-P1-C2-T4 0a6 R3-G03-P1-C2-T2   R3-G03-P1-C2-T4 0a8 R4-G05-P1-C2-T2
R3-G16-P1-C1-T3 0B5 R3-G04-P1-C1-T1   R3-G04-P1-C1-T3 0B7 R4-G06-P1-C1-T1
R3-G16-P1-C1-T4 0b5 R3-G04-P1-C1-T2   R3-G04-P1-C1-T4 0b7 R4-G06-P1-C1-T2
R3-G16-P1-C2-T3 0B6 R3-G04-P1-C2-T1   R3-G04-P1-C2-T3 0B8 R4-G06-P1-C2-T1
R3-G16-P1-C2-T4 0b6 R3-G04-P1-C2-T2   R3-G04-P1-C2-T4 0b8 R4-G06-P1-C2-T2
Table 5. FC-AL cabling matrix – DA Pair 3 (Models 985, 85E single-phase power)

From:

DA

Link

To:

FCIC

 

From:

FCIC

Link

To:

FCIC

R1-XI3-P1-C6-T1 3A1 R1-G03-P1-C1-T1   R1-G03-P1-C1-T3 3A3 R3-G13-P1-C1-T1
R1-XI4-P1-C3-T1 3a1 R1-G03-P1-C1-T2   R1-G03-P1-C1-T4 3a3 R3-G13-P1-C1-T2
R1-XI3-P1-C6-T2 3A2 R1-G03-P1-C2-T1   R1-G03-P1-C2-T3 3A4 R3-G13-P1-C2-T1
R1-XI4-P1-C3-T2 3a2 R1-G03-P1-C2-T2   R1-G03-P1-C2-T4 3a4 R3-G13-P1-C2-T2
R1-XI3-P1-C6-T3 3B1 R1-G04-P1-C1-T1   R1-G04-P1-C1-T3 3B3 R3-G14-P1-C1-T1
R1-XI4-P1-C3-T3 3b1 R1-G04-P1-C1-T2   R1-G04-P1-C1-T4 3b3 R3-G14-P1-C1-T2
R1-XI3-P1-C6-T4 3B2 R1-G04-P1-C2-T1   R1-G04-P1-C2-T3 3B4 R3-G14-P1-C2-T1
R1-XI4-P1-C3-T4 3b2 R1-G04-P1-C2-T2   R1-G04-P1-C2-T4 3b4 R3-G14-P1-C2-T2

From:

FCIC

Link

To:

FCIC

 

From:

FCIC

Link

To:

FCIC

R3-G13-P1-C1-T3 3A5 R3-G01-P1-C1-T1   R3-G01-P1-C1-T3 3A7 R4-G03-P1-C1-T1
R3-G13-P1-C1-T4 3a5 R3-G01-P1-C1-T2   R3-G01-P1-C1-T4 3a7 R4-G03-P1-C1-T2
R3-G13-P1-C2-T3 3A6 R3-G01-P1-C2-T1   R3-G01-P1-C2-T3 3A8 R4-G03-P1-C2-T1
R3-G13-P1-C2-T4 3a6 R3-G01-P1-C2-T2   R3-G01-P1-C2-T4 3a8 R4-G03-P1-C2-T2
R3-G14-P1-C1-T3 3B5 R3-G02-P1-C1-T1   R3-G02-P1-C1-T3 3B7 R4-G04-P1-C1-T1
R3-G14-P1-C1-T4 3b5 R3-G02-P1-C1-T2   R3-G02-P1-C1-T4 3b7 R4-G04-P1-C1-T2
R3-G14-P1-C2-T3 3B6 R3-G02-P1-C2-T1   R3-G02-P1-C2-T3 3B8 R4-G04-P1-C2-T1
R3-G14-P1-C2-T4 3b6 R3-G02-P1-C2-T2   R3-G02-P1-C2-T4 3b8 R4-G04-P1-C2-T2
Table 6. FC-AL cabling matrix – DA Pair 1 (Models 985, 85E single-phase power)

From:

DA

Link

To:

FCIC

 

From:

FCIC

Link

To:

FCIC

R1-XI1-P1-C6-T1 1A1 R1-G01-P1-C1-T1   R1-G01-P1-C1-T3 1A3 R3-G11-P1-C1-T1
R1-XI2-P1-C3-T1 1a1 R1-G01-P1-C1-T2   R1-G01-P1-C1-T4 1a3 R3-G11-P1-C1-T2
R1-XI1-P1-C6-T2 1A2 R1-G01-P1-C2-T1   R1-G01-P1-C2-T3 1A4 R3-G11-P1-C2-T1
R1-XI2-P1-C3-T2 1a2 R1-G01-P1-C2-T2   R1-G01-P1-C2-T4 1a4 R3-G11-P1-C2-T2
R1-XI1-P1-C6-T3 1B1 R1-G02-P1-C1-T1   R1-G02-P1-C1-T3 1B3 R3-G12-P1-C1-T1
R1-XI2-P1-C3-T3 1b1 R1-G02-P1-C1-T2   R1-G02-P1-C1-T4 1b3 R3-G12-P1-C1-T2
R1-XI1-P1-C6-T4 1B2 R1-G02-P1-C2-T1   R1-G02-P1-C2-T3 1B4 R3-G12-P1-C2-T1
R1-XI2-P1-C3-T4 1b2 R1-G02-P1-C2-T2   R1-G02-P1-C2-T4 1b4 R3-G12-P1-C2-T2

From:

FCIC

Link

To:

FCIC

 

From:

FCIC

Link

To:

FCIC

R3-G11-P1-C1-T3 1A5 R4-G17-P1-C1-T1   R4-G17-P1-C1-T3 1A7 R4-G01-P1-C1-T1
R3-G11-P1-C1-T4 1a5 R4-G17-P1-C1-T2   R4-G17-P1-C1-T4 1a7 R4-G01-P1-C1-T2
R3-G11-P1-C2-T3 1A6 R4-G17-P1-C2-T1   R4-G17-P1-C2-T3 1A8 R4-G01-P1-C2-T1
R3-G11-P1-C2-T4 1a6 R4-G17-P1-C2-T2   R4-G17-P1-C2-T4 1a8 R4-G01-P1-C2-T2
R3-G12-P1-C1-T3 1B5 R4-G18-P1-C1-T1   R4-G18-P1-C1-T3 1B7 R4-G02-P1-C1-T1
R3-G12-P1-C1-T4 1b5 R4-G18-P1-C1-T2   R4-G18-P1-C1-T4 1b7 R4-G02-P1-C1-T2
R3-G12-P1-C2-T3 1B6 R4-G18-P1-C2-T1   R4-G18-P1-C2-T3 1B8 R4-G02-P1-C2-T1
R3-G12-P1-C2-T4 1b6 R4-G18-P1-C2-T2   R4-G18-P1-C2-T4 1b8 R4-G02-P1-C2-T2
Table 7. FC-AL cabling matrix – DA Pair 6 (Models 985, 85E single-phase power)

From:

DA

Link

To:

FCIC

 

From:

FCIC

Link

To:

FCIC

R2-XI3-P1-C3-T1 6A1 R2-G03-P1-C1-T1   R2-G03-P1-C1-T3 6A3 R4-G15-P1-C1-T1
R2-XI4-P1-C6-T1 6a1 R2-G03-P1-C1-T2   R2-G03-P1-C1-T4 6a3 R4-G15-P1-C1-T2
R2-XI3-P1-C3-T2 6A2 R2-G03-P1-C2-T1   R2-G03-P1-C2-T3 6A4 R4-G15-P1-C2-T1
R2-XI4-P1-C6-T2 6a2 R2-G03-P1-C2-T2   R2-G03-P1-C2-T4 6a4 R4-G15-P1-C2-T2
R2-XI3-P1-C3-T3 6B1 R2-G04-P1-C1-T1   R2-G04-P1-C1-T3 6B3 R4-G16-P1-C1-T1
R2-XI4-P1-C6-T3 6b1 R2-G04-P1-C1-T2   R2-G04-P1-C1-T4 6b3 R4-G16-P1-C1-T2
R2-XI3-P1-C3-T4 6B2 R2-G04-P1-C2-T1   R2-G04-P1-C2-T3 6B4 R4-G16-P1-C2-T1
R2-XI4-P1-C6-T4 6b2 R2-G04-P1-C2-T2   R2-G04-P1-C2-T4 6b4 R4-G16-P1-C2-T2

From:

FCIC

Link

To:

FCIC

 

From:

FCIC

Link

To:

FCIC

R4-G15-P1-C1-T3 6A5 R5-G17-P1-C1-T1   R5-G17-P1-C1-T3 6A7 R5-G07-P1-C1-T1
R4-G15-P1-C1-T4 6a5 R5-G17-P1-C1-T2   R5-G17-P1-C1-T4 6a7 R5-G07-P1-C1-T2
R4-G15-P1-C2-T3 6A6 R5-G17-P1-C2-T1   R5-G17-P1-C2-T3 6A8 R5-G07-P1-C2-T1
R4-G15-P1-C2-T4 6a6 R5-G17-P1-C2-T2   R5-G17-P1-C2-T4 6a8 R5-G07-P1-C2-T2
R4-G16-P1-C1-T3 6B5 R5-G18-P1-C1-T1   R5-G18-P1-C1-T3 6B7 R5-G08-P1-C1-T1
R4-G16-P1-C1-T4 6b5 R5-G18-P1-C1-T2   R5-G18-P1-C1-T4 6b7 R5-G08-P1-C1-T2
R4-G16-P1-C2-T3 6B6 R5-G18-P1-C2-T1   R5-G18-P1-C2-T3 6B8 R5-G08-P1-C2-T1
R4-G16-P1-C2-T4 6b6 R5-G18-P1-C2-T2   R5-G18-P1-C2-T4 6b8 R5-G08-P1-C2-T2
Table 8. FC-AL cabling matrix – DA Pair 4 (Models 985, 85E single-phase power)

From:

DA

Link

To:

FCIC

 

From:

FCIC

Link

To:

FCIC

R2-XI1-P1-C3-T1 4A1 R2-G09-P1-C1-T1   R2-G09-P1-C1-T3 4A3 R2-G01-P1-C1-T1
R2-XI2-P1-C6-T1 4a1 R2-G09-P1-C1-T2   R2-G09-P1-C1-T4 4a3 R2-G01-P1-C1-T2
R2-XI1-P1-C3-T2 4A2 R2-G09-P1-C2-T1   R2-G09-P1-C2-T3 4A4 R2-G01-P1-C2-T1
R2-XI2-P1-C6-T2 4a2 R2-G09-P1-C2-T2   R2-G09-P1-C2-T4 4a4 R2-G01-P1-C2-T2
R2-XI1-P1-C3-T3 4B1 R2-G10-P1-C1-T1   R2-G10-P1-C1-T3 4B3 R2-G02-P1-C1-T1
R2-XI2-P1-C6-T3 4b1 R2-G10-P1-C1-T2   R2-G10-P1-C1-T4 4b3 R2-G02-P1-C1-T2
R2-XI1-P1-C3-T4 4B2 R2-G10-P1-C2-T1   R2-G10-P1-C2-T3 4B4 R2-G02-P1-C2-T1
R2-XI2-P1-C6-T4 4b2 R2-G10-P1-C2-T2   R2-G10-P1-C2-T4 4b4 R2-G02-P1-C2-T2

From:

FCIC

Link

To:

FCIC

 

From:

FCIC

Link

To:

FCIC

R2-G01-P1-C1-T3 4A5 R4-G13-P1-C1-T1   R4-G13-P1-C1-T3 4A7 R5-G15-P1-C1-T1
R2-G01-P1-C1-T4 4a5 R4-G13-P1-C1-T2   R4-G13-P1-C1-T4 4a7 R5-G15-P1-C1-T2
R2-G01-P1-C2-T3 4A6 R4-G13-P1-C2-T1   R4-G13-P1-C2-T3 4A8 R5-G15-P1-C2-T1
R2-G01-P1-C2-T4 4a6 R4-G13-P1-C2-T2   R4-G13-P1-C2-T4 4a8 R5-G15-P1-C2-T2
R2-G02-P1-C1-T3 4B5 R4-G14-P1-C1-T1   R4-G14-P1-C1-T3 4B7 R5-G16-P1-C1-T1
R2-G02-P1-C1-T4 4b5 R4-G14-P1-C1-T2   R4-G14-P1-C1-T4 4b7 R5-G16-P1-C1-T2
R2-G02-P1-C2-T3 4B6 R4-G14-P1-C2-T1   R4-G14-P1-C2-T3 4B8 R5-G16-P1-C2-T1
R2-G02-P1-C2-T4 4b6 R4-G14-P1-C2-T2   R4-G14-P1-C2-T4 4b8 R5-G16-P1-C2-T2
Table 9. FC-AL cabling matrix – DA Pair 7 (Models 985, 85E single-phase power)

From:

DA

Link

To:

FCIC

 

From:

FCIC

Link

To:

FCIC

R2-XI3-P1-C6-T1 7A1 R2-G07-P1-C1-T1   R2-G07-P1-C1-T3 7A3 R3-G09-P1-C1-T1
R2-XI4-P1-C3-T1 7a1 R2-G07-P1-C1-T2   R2-G07-P1-C1-T4 7a3 R3-G09-P1-C1-T2
R2-XI3-P1-C6-T2 7A2 R2-G07-P1-C2-T1   R2-G07-P1-C2-T3 7A4 R3-G09-P1-C2-T1
R2-XI4-P1-C3-T2 7a2 R2-G07-P1-C2-T2   R2-G07-P1-C2-T4 7a4 R3-G09-P1-C2-T2
R2-XI3-P1-C6-T3 7B1 R2-G08-P1-C1-T1   R2-G08-P1-C1-T3 7B3 R3-G10-P1-C1-T1
R2-XI4-P1-C3-T3 7b1 R2-G08-P1-C1-T2   R2-G08-P1-C1-T4 7b3 R3-G10-P1-C1-T2
R2-XI3-P1-C6-T4 7B2 R2-G08-P1-C2-T1   R2-G08-P1-C2-T3 7B4 R3-G10-P1-C2-T1
R2-XI4-P1-C3-T4 7b2 R2-G08-P1-C2-T2   R2-G08-P1-C2-T4 7b4 R3-G10-P1-C2-T2

From:

FCIC

Link

To:

FCIC

 

From:

FCIC

Link

To:

FCIC

R3-G09-P1-C1-T3 7A5 R4-G11-P1-C1-T1   R4-G11-P1-C1-T3 7A7 R5-G13-P1-C1-T1
R3-G09-P1-C1-T4 7a5 R4-G11-P1-C1-T2   R4-G11-P1-C1-T4 7a7 R5-G13-P1-C1-T2
R3-G09-P1-C2-T3 7A6 R4-G11-P1-C2-T1   R4-G11-P1-C2-T3 7A8 R5-G13-P1-C2-T1
R3-G09-P1-C2-T4 7a6 R4-G11-P1-C2-T2   R4-G11-P1-C2-T4 7a8 R5-G13-P1-C2-T2
R3-G10-P1-C1-T3 7B5 R4-G12-P1-C1-T1   R4-G12-P1-C1-T3 7B7 R5-G14-P1-C1-T1
R3-G10-P1-C1-T4 7b5 R4-G12-P1-C1-T2   R4-G12-P1-C1-T4 7b7 R5-G14-P1-C1-T2
R3-G10-P1-C2-T3 7B6 R4-G12-P1-C2-T1   R4-G12-P1-C2-T3 7B8 R5-G14-P1-C2-T1
R3-G10-P1-C2-T4 7b6 R4-G12-P1-C2-T2   R4-G12-P1-C2-T4 7b8 R5-G14-P1-C2-T2
Table 10. FC-AL cabling matrix – DA Pair 5 (Models 985, 85E single-phase power)

From:

DA

Link

To:

FCIC

 

From:

FCIC

Link

To:

FCIC

R2-XI1-P1-C6-T1 5A1 R2-G05-P1-C1-T1   R2-G05-P1-C1-T3 5A3 R3-G07-P1-C1-T1
R2-XI2-P1-C3-T1 5a1 R2-G05-P1-C1-T2   R2-G05-P1-C1-T4 5a3 R3-G07-P1-C1-T2
R2-XI1-P1-C6-T2 5A2 R2-G05-P1-C2-T1   R2-G05-P1-C2-T3 5A4 R3-G07-P1-C2-T1
R2-XI2-P1-C3-T2 5a2 R2-G05-P1-C2-T2   R2-G05-P1-C2-T4 5a4 R3-G07-P1-C2-T2
R2-XI1-P1-C6-T3 5B1 R2-G06-P1-C1-T1   R2-G06-P1-C1-T3 5B3 R3-G08-P1-C1-T1
R2-XI2-P1-C3-T3 5b1 R2-G06-P1-C1-T2   R2-G06-P1-C1-T4 5b3 R3-G08-P1-C1-T2
R2-XI1-P1-C6-T4 5B2 R2-G06-P1-C2-T1   R2-G06-P1-C2-T3 5B4 R3-G08-P1-C2-T1
R2-XI2-P1-C3-T4 5b2 R2-G06-P1-C2-T2   R2-G06-P1-C2-T4 5b4 R3-G08-P1-C2-T2

From:

FCIC

Link

To:

FCIC

 

From:

FCIC

Link

To:

FCIC

R3-G07-P1-C1-T3 5A5 R4-G09-P1-C1-T1   R4-G09-P1-C1-T3 5A7 R5-G11-P1-C1-T1
R3-G07-P1-C1-T4 5a5 R4-G09-P1-C1-T2   R4-G09-P1-C1-T4 5a7 R5-G11-P1-C1-T2
R3-G07-P1-C2-T3 5A6 R4-G09-P1-C2-T1   R4-G09-P1-C2-T3 5A8 R5-G11-P1-C2-T1
R3-G07-P1-C2-T4 5a6 R4-G09-P1-C2-T2   R4-G09-P1-C2-T4 5a8 R5-G11-P1-C2-T2
R3-G08-P1-C1-T3 5B5 R4-G10-P1-C1-T1   R4-G10-P1-C1-T3 5B7 R5-G12-P1-C1-T1
R3-G08-P1-C1-T4 5b5 R4-G10-P1-C1-T2   R4-G10-P1-C1-T4 5b7 R5-G12-P1-C1-T2
R3-G08-P1-C2-T3 5B6 R4-G10-P1-C2-T1   R4-G10-P1-C2-T3 5B8 R5-G12-P1-C2-T1
R3-G08-P1-C2-T4 5b6 R4-G10-P1-C2-T2   R4-G10-P1-C2-T4 5b8 R5-G12-P1-C2-T2

Flash PCIe cables

  1. Flash PCIe cables and connectors are identified with a colored band matching the DA pair and two different color codes:
    • A colored band, corresponding to the color code of the DA pair, is found on each end of the cable near the connector. These color codes are shown in Figure 1.
    • The connector is color-coded to help prevent cross-cabling at the microbay adapter card or I/O enclosure PCIe and PCN card end. Connectors on cables attaching to Rx-Mxx-C1-T7 have white labels with black text, and connectors on cables attaching to Rx-Mxx-C2-T7 have black labels with white text. An example of this showing both cables attaching to a microbay adapter card pair is shown in Figure 5. This alternating color scheme is the same for all Flash PCIe cables, and is independent of the DA pair color code. Figure 6 and Figure 7 show the Flash PCIe cable connection ends.
  2. The black and white label at each end has a physical location code showing the "FROM" and "TO" end.
Figure 5. Flash PCIe cable connector example. Both cables are shown and actual values might not match this machine model.
Flash PCIe cable connector example; both cables are shown and actual values might not match this machine model.
Figure 6. Flash PCIe cable connector - Microbay adapter card end (C1-T7 / C2-T7)
Flash PCIe cable connector - Microbay adapter card end (C1-T7 / C2-T7)
Figure 7. Flash PCIe cable connector - I/O enclosure PCIe and PCN card end (-C7-T5 / -C7-T6)
I/O enclosure locations (rear) (models 98x)

Flash SAS cables

  1. SAS cables and connectors are identified with two different color codes and a location designator:
    1. A colored band, corresponding to the color code of the DA pair, is found on each end of the cable near the connector. These color codes are shown in Figure 1.
    2. The connector itself is color coded to help prevent cross-cabling at the SAS expander card or device adapter card (DA) end. The connectors always appear in the following order:
      white (T1), green (T2), black (T3), and blue (T4)
      as shown in Figure 9 and Figure 10 . This color code is specific to each SAS expander card or DA, and is independent of the DA pair color code.
    3. A black or white label at each end of the cable shows a location designator (for example, 16A1). Both ends of the cable have the same location designator and DA pair color code. However, the connector at each end of the same cable usually does NOT have the same color code.
    4. The following alternating color scheme is the same for all Flash SAS cables, and is independent of the DA pair color code.
      • Connectors on cables that attach to Rx-Mxx-C1-Tx have white labels with black text
      • Connectors on cables that attach to Rx-Mxx-C2-Tx have black labels with white text
      • Connectors on cables that attach to Rx-Mxx-C1-Tx have white labels with black text
      • Connectors on cables that attach to Rx-Mxx-C2-Tx have black labels with white text

    An example of SAS cables and connectors that shows both ends of two SAS cables to an enclosure is shown in Figure 8.

  2. Location designators are in the form CTP, where:
    C
    Is the device adapter pair (16-23).
    T
    Is the port pair on the device adapter (A, B, a, b) (uppercase for left device adapter in pair, lowercase for right device adapter in pair).
    P
    Is the logical position of the downstream SAS expander card.
    Example: 16a1 is the link between device adapter R1-M02-C2-T1 and R1-F01-P1-C1-T2.
    16
    Device adapter pair 16
    a
    First port pair on right adapter of device adapter pair (lowercase a)
    1
    First SAS expander card
    The colored connector band plugged into R1-M02-C2-T1 (16a1) is white, while the colored connector band plugged into R1-F01-P1-C1-T2 (16a1) is green.
  3. The black and white label at each end may have a physical location code in addition to the location designator.
Figure 8. Flash SAS cable connector example. Two cables shown. Actual values might not match this machine model.
Flash SAS cable connector example. Two cables shown; actual values might not match this machine model.
Figure 9. Flash SAS cable connector color codes - SAS expander card end
Flash SAS cable connector color codes - SAS expander card end
Figure 10. Flash SAS cable connector color codes - microbay adapter end
Flash SAS cable connector color codes - microbay adapter end

Flash PCIe and SAS cabling tables

Table 11 and Table 12 show a summary of Flash PCIe / SAS cabling for models 985 and 85E single-phase power.
Table 13 and Table 14 show details of the Flash PCIe / SAS cabling with Rack 1 high-performance flash enclosures (device adapter pairs 16 and 18, in normal installation order).
Table 15 and Table 16 show details of the Flash PCIe / SAS cabling with Rack 2 high-performance flash enclosures (device adapter pairs 20 and 22, in normal installation order).
Note: Location designators are labeled as link in the following tables.
Table 11. Flash PCIe / SAS cabling summary – Rack 1 device adapters (Models 985, 85E single-phase power)
From DA pair DA pair (link) To Microbay To storage enclosure To storage enclosure
R1-XI3-P1-C7-T5
R1-XI4-P1-C7-T6
18 (A)
18 (B)
R1-M04 R1-F03 R1-F04
R1-XI1-P1-C7-T5
R1-XI2-P1-C7-T6
16 (A)
16 (B)
R1-M02 R1-F01 R1-F02
Table 12. Flash PCIe / SAS cabling summary – Rack 2 device adapters (Models 985, 85E single-phase power)
From DA pair DA pair (link) To Microbay To storage enclosure To storage enclosure
R2-XI3-P1-C7-T5
R2-XI4-P1-C7-T6
22 (A)
22 (B)
R2-M04 R2-F03 R2-F04
R2-XI1-P1-C7-T5
R2-XI2-P1-C7-T6
20 (A)
20 (B)
R2-M02 R2-F01 R2-F02
Table 13. Flash PCIe / SAS cabling matrix – DA Pair 18 (Models 985, 85E single-phase power)

From:

DA

Link

To:

Microbay

 

From:

Microbay

Link

To:

Flash enclosure

R1-XI3-P1-C7-T5 18A R1-M04-C1-T7   R1-M04-C1-T1 18A1 R1-F03-P1-C1-T1
  R1-M04-C2-T1 18a1 R1-F03-P1-C1-T2
  R1-M04-C1-T2 18A2 R1-F03-P1-C2-T1
  R1-M04-C2-T2 18a2 R1-F03-P1-C2-T2
R1-XI4-P1-C7-T6 18B R1-M04-C2-T7   R1-M04-C1-T3 18B1 R1-F04-P1-C1-T1
  R1-M04-C2-T3 18b1 R1-F04-P1-C1-T2
  R1-M04-C1-T4 18B2 R1-F04-P1-C2-T1
  R1-M04-C2-T4 18b2 R1-F04-P1-C2-T2
Table 14. Flash PCIe / SAS cabling matrix – DA Pair 16 (Models 985, 85E single-phase power)

From:

DA

Link

To:

Microbay

 

From:

Microbay

Link

To:

Flash enclosure

R1-XI1-P1-C7-T5 16A R1-M02-C1-T7   R1-M02-C1-T1 16A1 R1-F01-P1-C1-T1
  R1-M02-C2-T1 16a1 R1-F01-P1-C1-T2
  R1-M02-C1-T2 16A2 R1-F01-P1-C2-T1
  R1-M02-C2-T2 16a2 R1-F01-P1-C2-T2
R1-XI2-P1-C7-T6 16B R1-M02-C2-T7   R1-M02-C1-T3 16B1 R1-F02-P1-C1-T1
  R1-M02-C2-T3 16b1 R1-F02-P1-C1-T2
  R1-M02-C1-T4 16B2 R1-F02-P1-C2-T1
  R1-M0-C2-T4 16b2 R1-F02-P1-C2-T2
Table 15. Flash PCIe / SAS cabling matrix – DA Pair 22 (Models 985, 85E single-phase power)

From:

DA

Link

To:

Microbay

 

From:

Microbay

Link

To:

Flash enclosure

R2-XI3-P1-C7-T5 22A R2-M04-C1-T7   R2-M04-C1-T1 22A1 R2-F03-P1-C1-T1
  R2-M04-C2-T1 22a1 R2-F03-P1-C1-T2
  R2-M04-C1-T2 22A2 R2-F03-P1-C2-T1
  R2-M04-C2-T2 22a2 R2-F03-P1-C2-T2
R2-XI4-P1-C7-T6 22B R2-M04-C2-T7   R2-M04-C1-T3 22B1 R2-F04-P1-C1-T1
  R2-M04-C2-T3 22b1 R2-F04-P1-C1-T2
  R2-M04-C1-T4 22B2 R2-F04-P1-C2-T1
  R2-M04-C2-T4 22b2 R2-F04-P1-C2-T2
Table 16. Flash PCIe / SAS cabling matrix – DA Pair 20 (Models 985, 85E single-phase power)

From:

DA

Link

To:

Microbay

 

From:

Microbay

Link

To:

Flash enclosure

R2-XI1-P1-C7-T5 20A R2-M02-C1-T7   R2-M02-C1-T1 20A1 R2-F01-P1-C1-T1
  R2-M02-C2-T1 20a1 R2-F01-P1-C1-T2
  R2-M02-C1-T2 20A2 R2-F01-P1-C2-T1
  R2-M02-C2-T2 20a2 R2-F01-P1-C2-T2
R2-XI2-P1-C7-T6 20B R2-M02-C2-T7   R2-M02-C1-T3 20B1 R2-F02-P1-C1-T1
  R2-M02-C2-T3 20b1 R2-F02-P1-C1-T2
  R2-M02-C1-T4 20B2 R2-F02-P1-C2-T1
  R2-M02-C2-T4 20b2 R2-F02-P1-C2-T2