Table 1. I/O enclosure locations (front)
Part Reference
I/O enclosure fan Figure 2
I/O enclosure power supply Figure 2
Table 2. I/O enclosure locations (rear)
Part Reference
PCIe and PCN card Figure 4
I/O enclosure backplane assembly Figure 4
I/O enclosure device adapter card Figure 5
I/O enclosure device adapter card, SAS (flash) Figure 8
I/O enclosure Fibre Channel host card Figure 6
I/O enclosure PCIe storage interface card Figure 7
Microbay Figure 9
Figure 10
Note: Microbays are located behind the associated flash enclosures, but are displayed by service processes as a subassembly of the associated I/O enclosures.

I/O enclosure locations (front)

Figure 1. I/O enclosure locations (front) (models 98x, 8xE)
Image that shows the front I/O enclosure locations (models 98x).
Note: Enclosures 1B1, 1B2, 2B1, and 2B2 are not present in some models.
Figure 2. I/O enclosure locations (front) (models 98x, 8xE)
I/O enclosure locations (front) (models 98x)
Table 3. Location codes for the I/O enclosure (front)
Location code Part name Connector
U1500.rBn.sssssss-A11 I/O enclosure fan  
U1500.rBn.sssssss-A21 I/O enclosure fan  
U1500.rBn.sssssss-E11 I/O enclosure power supply  
U1500.rBn.sssssss-E21 I/O enclosure power supply  
Note:
  1. rBn where: r = rack (1-2); Bn = I/O enclosure (1-4); see Figure 1.

I/O enclosure locations (rear)

Figure 3. I/O enclosure locations (rear)
Image that shows I/O enclosure locations (rear)
Note: Enclosures 1B1, 1B2, 2B1, and 2B2 are not present in models 980, 984 (except all-flash), 98B, 84E.
Figure 4. I/O enclosure locations (rear) (models 98x, 8xE)
I/O enclosure locations (rear) (models 98x, 8xE)
Notes:
  • The older generation I/O enclosure PCIe and PCN card might not include T3, T4, and T10 ports.
Figure 5. Model 98x location codes for the device adapter card
Location codes for the device adapter card SAS ports
Figure 6. Model 98x location codes for the I/O enclosure Fibre Channel host card (8-port shown; 4-port is similar)
Image that shows location codes for the I/O enclosure Fibre Channel host card
Figure 7. Model 982, 98F location codes for the I/O enclosure PCIe storage interface card
Model 982, 98F location codes for the I/O enclosure PCIe storage interface card
Figure 8. Flash SAS cable connectors - Device adapter card, SAS (flash) (Cx-T1, T2, T3, T4)
Flash SAS cable connectors - Device adapter card, SAS (flash) (Cx-T1, T2, T3, T4)
Table 4. Location codes for the I/O enclosure (rear)
Location code Part name Connector
U1500.rBn.sssssss1 I/O enclosure  
U1500.rBn.sssssss-P11 I/O enclosure backplane assembly  
U1500.rBn.sssssss-P1-Cx1
   (x = 1, 2, 4, 5)
I/O enclosure Fibre Channel host card
(short wave, long wave)
 
U1500.rBn.sssssss-P1-Cx-Ty1,2
   (x = 1, 2, 4, 5)
   (y = 0, 1, 2, 3, 4, 5, 6, 7, top to bottom)    
  Customer Fibre cable
U1500.rBn.sssssss-P1-Cx1
   (x = 3, 6)
I/O enclosure device adapter card  
U1500.rBn.sssssss-P1-Cx-Ty1, 2
   (x = 3, 6)
   (y = 1, 2, 3, 4, top to bottom)
 
FC-AL cable
U1500.rBn.sssssss-P1-Cx1
(x = 3, 6)
I/O enclosure device adapter card, SAS (flash)  
U1500.rBn.sssssss-P1-Cx-Ty1, 2
(x = 3, 6)
(y = 1, 2, 3, 4, top to bottom)
  SAS cable
U1500.rBn.sssssss-P1-Cx1
(x = 3, 6)
I/O enclosure PCIe storage interface card  
U1500.rBn.sssssss-P1-Cx-T11
(x = 3, 6)
  PCIe cable
U1500.rBn.sssssss-P1-C71 I/O enclosure PCIe and PCN card  
U1500.rBn.sssssss-P1-C7-T11   PCIe (CXP)
U1500.rBn.sssssss-P1-C7-T21   PCIe (CXP)
U1500.rBn.sssssss-P1-C7-T31   PCIe (CXP)
U1500.rBn.sssssss-P1-C7-T41   PCIe (CXP)
U1500.rBn.sssssss-P1-C7-T51   PCIe (CXP)
U1500.rBn.sssssss-P1-C7-T61   PCIe (CXP)
U1500.rBn.sssssss-P1-C7-T71   PCN
U1500.rBn.sssssss-P1-C7-T81   PCN
U1500.rBn.sssssss-P1-C7-T91   (Not used)
U1500.rBn.sssssss-P1-C7-T101   Power
Notes:
  1. rBn where: r = rack (1-2); Bn = I/O enclosure (1-4); see Figure 3.
  2. Some physical location codes begin at zero and count upwards, others begin at one and count upwards. The storage facility uses parts from different hardware platforms. Most Licensed Internal Code and firmware logical resources identifiers begin at zero and count upwards.
  3. Some PCIe and PCN cards do not include ports C7-T3, C7-T4, or C7-T10.
Figure 9. Microbay tray locations
Microbay tray locations
Figure 10. Microbay location codes
Microbay location codes
Table 5. Location codes for the microbay
Location code Part name Connector
U1500.rBn.sssssss-P1-C7-C11, 2

Microbay (left)

 
U1500.rBn.sssssss-P1-C7-C21, 2

Microbay (right)

U1500.rBn.sssssss-P1-C7-Cx-T11, 2
(x = 1, 2)
  SAS cable
U1500.rBn.sssssss-P1-C7-Cx-T21, 2
(x = 1, 2)
  SAS cable
U1500.rBn.sssssss-P1-C7-Cx-T31, 2
(x = 1, 2)
  SAS cable
U1500.rBn.sssssss-P1-C7-Cx-T41, 2
(x = 1, 2)
  SAS cable
U1500.rBn.sssssss-P1-C7-Cx-T51, 2
(x = 1, 2)
  Not used
U1500.rBn.sssssss-P1-C7-Cx-T61, 2
(x = 1, 2)
  Power
U1500.rBn.sssssss-P1-C7-Cx-T71, 2
(x = 1, 2)
  PCIe (CXP)
Notes:
  1. rBn where: r = rack (1-2); Bn = I/O enclosure (1-4); see Figure 3.
  2. Microbay locations are reported as a subassembly of the I/O enclosure PCIe and PCN card. Each microbay is located behind the associated flash enclosure. For example, R1-M04 is located behind R1-F04. See Storage enclosure location codes (Models 98x, SAS flash enclosure, 24 drive slots, 2.5 inches).
Table 6. Microbay locations by model (Rack-1)
I/O enclosure location code MES location code, PCIe and PCN card connector Microbay alias
(model 988)
Microbay alias
(models 985, 986)
Microbay alias
(model 984)
U1500.1B1.sssssss-P1-C7-C11 R1-XI1-P1-C7-T5 R1-M06-C1 R1-M02-C1 R1-M08-C12
U1500.1B1.sssssss-P1-C7-C21 R1-XI1-P1-C7-T6 R1-M02-C2 R1-M06-C22 R1-M06-C22
U1500.1B2.sssssss-P1-C7-C11 R1-XI2-P1-C7-T5 R1-M02-C1 R1-M06-C12 R1-M06-C12
U1500.1B2.sssssss-P1-C7-C21 R1-XI2-P1-C7-T6 R1-M06-C2 R1-M02-C2 R1-M08-C22
U1500.1B3.sssssss-P1-C7-C11 R1-XI3-P1-C7-T5 R1-M08-C1 R1-M04-C1 R1-M04-C1
U1500.1B3.sssssss-P1-C7-C21 R1-XI3-P1-C7-T6 R1-M04-C2 R1-M08-C22 R1-M02-C22
U1500.1B4.sssssss-P1-C7-C11 R1-XI4-P1-C7-T5 R1-M04-C1 R1-M08-C12 R1-M02-C12
U1500.1B4.sssssss-P1-C7-C21 R1-XI4-P1-C7-T6 R1-M08-C2 R1-M04-C2 R1-M04-C2
Notes:
  1. Microbay locations are reported as a subassembly of the I/O enclosure PCIe and PCN card. Each microbay is located behind the associated flash enclosure. For example, R1-M04 is located behind R1-F04. See Storage enclosure location codes (Models 98x, SAS flash enclosure, 24 drive slots, 2.5 inches).
  2. All-flash (machine types 533x, 9586) only.
Table 7. Microbay locations by model (Rack-2)
I/O enclosure location code MES location code, PCIe and PCN card connector Microbay alias
(model 88E)
Microbay alias
(models 85E, 86E)
Microbay alias
(model 84E)
U1500.2B1.sssssss-P1-C7-C11 R2-XI1-P1-C7-T5 R2-M10-C1 R2-M02-C1 N/A
U1500.2B1.sssssss-P1-C7-C21 R2-XI1-P1-C7-T6 R2-M06-C2 R2-M06-C22 N/A
U1500.2B2.sssssss-P1-C7-C11 R2-XI2-P1-C7-T5 R2-M06-C1 R2-M06-C12 N/A
U1500.2B2.sssssss-P1-C7-C21 R2-XI2-P1-C7-T6 R2-M10-C2 R2-M02-C2 N/A
U1500.2B3.sssssss-P1-C7-C11 R2-XI3-P1-C7-T5 R2-M12-C1 R2-M04-C1 R2-M04-C1
U1500.2B3.sssssss-P1-C7-C21 R2-XI3-P1-C7-T6 R2-M08-C2 R2-M08-C22 N/A
U1500.2B4.sssssss-P1-C7-C11 R2-XI4-P1-C7-T5 R2-M08-C1 R2-M08-C12 N/A
U1500.2B4.sssssss-P1-C7-C21 R2-XI4-P1-C7-T6 R2-M12-C2 R2-M04-C2 R2-M04-C2
Notes:
  1. Microbay locations are reported as a subassembly of the I/O enclosure PCIe and PCN card. Each microbay is located behind the associated flash enclosure. For example, R1-M04 is located behind R1-F04. See Storage enclosure location codes (Models 98x, SAS flash enclosure, 24 drive slots, 2.5 inches).
  2. All-flash (machine types 533x, 9586) only.
Table 8. Microbay locations by model (Rack-1) (Models 980 and 981 with HPFE Gen2)
I/O enclosure location code MES location code, PCIe and PCN card connector Microbay alias
(model 980)
Microbay alias
(model 981 1-phase)
Microbay alias
(model 981 3-phase)
U1500.1B1.sssssss-P1-C7-C11 R1-XI1-P1-C7-T5 N/A N/A N/A
U1500.1B1.sssssss-P1-C7-C21 R1-XI1-P1-C7-T6 N/A R1-M06-C2 R1-M04-C2
U1500.1B2.sssssss-P1-C7-C11 R1-XI2-P1-C7-T5 N/A R1-M06-C1 R1-M04-C1
U1500.1B2.sssssss-P1-C7-C21 R1-XI2-P1-C7-T6 N/A N/A N/A
U1500.1B3.sssssss-P1-C7-C11 R1-XI3-P1-C7-T5 N/A N/A N/A
U1500.1B3.sssssss-P1-C7-C21 R1-XI3-P1-C7-T6 R1-M10-C2 R1-M08-C2 R1-M06-C2
U1500.1B4.sssssss-P1-C7-C11 R1-XI4-P1-C7-T5 R1-M10-C1 R1-M08-C1 R1-M06-C1
U1500.1B4.sssssss-P1-C7-C21 R1-XI4-P1-C7-T6 N/A N/A N/A
Notes:
  1. Microbay locations are reported as a subassembly of the I/O enclosure PCIe and PCN card. Each microbay is located behind a predefined storage enclosure location. For example, R1-M04 is located behind R1-G04. See Storage enclosure location codes (Models 98x, FC/SAS, 12 and 24 drive slots). The associated HPFE Gen2 enclosure pair can be located in a different rack than the microbay pair, or in a different location in the same rack.
Table 9. Microbay locations by model (Rack-2) (Models 98B and 98E with HPFE Gen2)
I/O enclosure location code MES location code, PCIe and PCN card connector Microbay alias
(model 98B)
Microbay alias
(model 98E 1-phase)
Microbay alias
(model 981 3-phase)
U1500.2B1.sssssss-P1-C7-C11 R2-XI1-P1-C7-T5 N/A N/A N/A
U1500.2B1.sssssss-P1-C7-C21 R2-XI1-P1-C7-T6 N/A R2-M10-C2 R2-M08-C2
U1500.2B2.sssssss-P1-C7-C11 R2-XI2-P1-C7-T5 N/A R2-M10-C1 R2-M08-C1
U1500.2B2.sssssss-P1-C7-C21 R2-XI2-P1-C7-T6 N/A N/A N/A
U1500.2B3.sssssss-P1-C7-C11 R2-XI3-P1-C7-T5 N/A N/A N/A
U1500.2B3.sssssss-P1-C7-C21 R2-XI3-P1-C7-T6 R2-M12-C2 R2-M12-C2 R2-M10-C2
U1500.2B4.sssssss-P1-C7-C11 R2-XI4-P1-C7-T5 R2-M12-C1 R2-M12-C1 R2-M10-C1
U1500.2B4.sssssss-P1-C7-C21 R2-XI4-P1-C7-T6 N/A N/A N/A
Notes:
  1. Microbay locations are reported as a subassembly of the I/O enclosure PCIe and PCN card. Each microbay is located behind a predefined storage enclosure location. For example, R1-M04 is located behind R1-G04. See Storage enclosure location codes (Models 98x, FC/SAS, 12 and 24 drive slots). The associated HPFE Gen2 enclosure pair can be located in a different rack than the microbay pair, or in a different location in the same rack.
Table 10. Location codes for direct power junction assembly (direct PJA)
I/O enclosure location code MES location code PJA alias
U1500.1B1.sssssss-P1-C7-E1 R1-XI1-P1-C7-E1 R1-E53
U1500.1B2.sssssss-P1-C7-E1 R1-XI2-P1-C7-E1 R1-E54
U1500.1B3.sssssss-P1-C7-E1 R1-XI3-P1-C7-E1 R1-E51
U1500.1B4.sssssss-P1-C7-E1 R1-XI4-P1-C7-E1 R1-E52
U1500.2B1.sssssss-P1-C7-E1 R2-XI1-P1-C7-E1 R2-E53
U1500.2B2.sssssss-P1-C7-E1 R2-XI2-P1-C7-E1 R2-E54
U1500.2B3.sssssss-P1-C7-E1 R2-XI3-P1-C7-E1 R2-E51
U1500.2B4.sssssss-P1-C7-E1 R2-XI4-P1-C7-E1 R2-E52
Note: Direct PJA locations are reported as a subassembly of the I/O enclosure PCIe and PCN card.

For physical locations, see Rack power and cooling location codes (Models 98x) (not 983).

For power cabling, see Power distribution cables.