MAP1410 Repairing a problem found by the secure data overwrite process
About this task
- Display and repair of other open serviceable events
- Closure of the serviceable event that sent you here
- Restart of SDO
MAP1410 Section-1
About this task
| System Reference Code | Description/Action |
|---|---|
| BE33CE7E | Description: The device adapter cards reported
that the storage enclosure drives failed the secure data overwrite process for customer data
drives. Additional details: Secure data overwrite (SDO) completes successfully, however one or more customer data drives (storage enclosure drives) failed to complete their individual SDO (multi-pass data overwrite, cryptographic erase, or N-pass overwrite with cryptographic erase) process. The remainder of the SDO processes complete. The failed drives are listed in the SDO completion certificate and also have open serviceable events. The disposition of the failed drives is determined by the customer. Action: Go to MAP1410 Section-2. |
| BE610010 | Description: Secure data overwrite process
for customer data drives completed successfully. Action: Information only. No further action required. |
| BE610011 | Description: Secure data overwrite process
for customer data drives failed on customer data disks. Action: Perform standard SDO recovery, as described in Note 1. |
| BE610012 | Description: Secure data overwrite process
for customer data drives failed to generate SDO completion certificate. Action: Perform standard SDO recovery, as described in Note 1. |
| BE610013 | Description: Secure data overwrite process
for customer data drives failed when it detected that status is corrupted. Action: Perform standard SDO recovery, as described in Note 1. |
| BE610014 | Description: Secure data overwrite process
for customer data drives failed to start monitoring process. Action: Perform standard SDO recovery, as described in Note 1. |
| BE610015 | Description: Secure data overwrite process
for customer data drives failed when it detected an unexpected error. Action: Perform standard SDO recovery, as described in Note 1. |
| BE610016 | Description: Secure data overwrite process
for customer data drives failed when a pre-check process detected
an error. Action: Perform standard SDO recovery, as described in Note 1. |
| BE610017 | Description: Secure data overwrite process
for customer data drives failed when it detected an incorrect storage
facility state. Action:
|
| BE610018 | Description: Secure data overwrite process
for customer data drives failed when it detected customer logical
configuration not fully removed. Action:
|
| BE610019 | Description: Secure data overwrite process for customer data drives
detected another process in progress. Action: Close this serviceable event. SDO is running. |
| BE61001A | Description: Secure data overwrite process
for customer data drives reports kernel data ready for collection
by SDO LPAR process. Action: Contact your next level of support. |
| BE61001B | Description: Secure data overwrite process
for customer data drives failed when it could not reset adapter configuration. Action: Perform standard SDO recovery, as described in Note 1. |
| BE61001C | Description: Secure data overwrite process
for customer data drives failed with an unexpected microcode logic
error. Action: Perform standard SDO recovery, as described in Note 1. |
| BE61001D | Description: Secure data overwrite process
for customer data drives failed when it started on LPAR1 instead of
LPAR0. Not a user error. Action: Perform standard SDO recovery, as described in Note 1. |
| BE610020 | Description: Secure data overwrite process
completed successfully on CEC enclosure disk drives. Action: Information only. No further action required. |
| BE610021 | Description: Secure data overwrite process
failed on CEC enclosure disk drives. Action: Contact your next level of support. |
| BE610030 | Description: Secure data overwrite process completed successfully on
all managed storage facilities. Additional details: This SRC indicates SDO completed successfully. The serviceable event text might include the additional messages "one or more customer drives failed SDO process", "reset service intent failed", or both. If either message is included, SDO still completed successfully, but more actions are required. Case 1: SRC BE610030 with no additional messages. Action: Information only. No further action required. Case 2: SRC BE610030 with additional message, "one or more customer drives failed SDO process." Action: Look for serviceable events that contain SRC BE33CE7E. Refer to BE33CE7E in this table. Case 3: SRC BE610030 with additional message, "reset service intent failed." Action: Go to MAP1410 Section-3. Case 4: SRC BE610030 with both additional messages, "one or more customer drives failed SDO process" and "reset service intent failed." Action: Perform actions for MAP1410 Section-3. Then look for serviceable events that contain SRC BE33CE7E. Refer to BE33CE7E in this table. |
| BE610031 | Description: Secure data overwrite process
failed on one or all managed storage facilities. Action: Perform standard SDO recovery, as described in Note 1. |
| BE610034 | Description: Secure data overwrite process stopped due to an unexpected
reboot of the HMC in the middle of the overwrite process. Additional details: The process stopped on the HMC only. Secure Data Overwrite processes on the CEC enclosure disk drives and customer data drives are not affected. Restarting the SDO process on the HMC allows the process to proceed on the HMC. The HMC process detects that the other SDO processes are either still running or are complete. Any failures are reported by separate serviceable events. Action: Restart secure data overwrite on the HMC. |
| BE610035 | Description: Secure data overwrite process
failed when the HMC failed to generate SDO completion certificate(s). Action: Perform standard SDO recovery, as described in Note 1. |
| BE610040 | Description: Secure data overwrite process
completed successfully on the secondary HMC. Action: Information only. No further action required. |
| BE610041 | Description: Secure data overwrite process
failed on the secondary HMC. Action:
|
| BE610042 | Description: Secure data overwrite process
did not complete on the secondary HMC. Action:
|
| BE610043 | Description: Secure data overwrite process
completed successfully on the primary HMC. Action: Information only. No further action required. |
| BE610044 | Description: Secure data overwrite process
failed on the primary HMC. Action: Perform standard SDO recovery, as described in Note 1. |
| BE610050 | Description: Secure data overwrite process
failed when it timed out from HMC WUI interface. Action: Perform standard SDO recovery, as described in Note 1. |
| BE610051 | Description: Secure data overwrite process
failed when RMC (HMC - LPAR) communication failed. Action: Perform standard SDO recovery, as described in Note 1. |
| BE610060 | Description: Secure data overwrite process
SDO completion certificate offloaded successfully. Action: Information only. No further action required. |
| BE83CBC3 | Description: The device adapter cards
reported that the storage enclosure drives failed the secure data overwrite process for customer
data drives. Additional details: Secure data overwrite (SDO) completes successfully, however one or more customer data drives (storage enclosure drives) failed to complete their individual SDO (cryptographic erase, N-pass overwrite with cryptographic erase, or cryptographic erase with block sanitize erase) process. The remainder of the SDO processes complete. The failed drives are listed in the SDO completion certificate and also have open serviceable events. The disposition of the failed drives is determined by the customer. Action: Go to MAP1410 Section-2. |
Note 1: Standard SDO recovery:
|
|
MAP1410 Section-2
About this task
One or more customer data drives (storage enclosure drives) failed to complete their individual SDO (multi-pass data overwrite, cryptographic erase, N-pass overwrite with cryptographic erase, or cryptographic erase with block sanitize erase) process.
Procedure
MAP1410 Section-3
About this task
Secure data overwrite completed successfully, but "reset service intent" failed. Service intent must be reset before any logical configuration can be performed.
Procedure
- From the navigation area, click .
- From the bottom Tasks area, click Reset Service Intent.