MAP2190 Rack battery backup set charge low
The batteries in each rack are connected as N+1 (redundant). As soon as line cord AC is connected to the PPSs in a rack, both PPSs in that rack begin charging the batteries. When a battery low condition is reported, the maximum recharge time for the battery backup system has been exceeded so multiple independent failures are indicated.
About this task
- When the battery low condition occurs while the SFI is operational, microcode will log the failure and immediately initiate a forced power off.
- When the battery low is detected during the first SFI IML, microcode will
pause the IML until the condition is resolved or will time out, log the condition,
and boot to AIX.
For either case, the SFI will not be operational and the normal methods of repair will not be possible.