MAP4075 Restoring VPD after replacing the CEC enclosure I/O backplane assembly (Models 94x, 95x)
If you replace the I/O backplane assembly in the CEC enclosure, you must
manually restore the vital product data (VPD) settings. Use this MAP
to restore the settings.
MAP4075 Section-1
Procedure
- Login to the service processor ASM
interface from the HMC using the user ID celogin and
password FipSce.
- From the ASMI navigation, select , then select
the menu option that is listed in the first column of Table 1.
Table 1. System Enclosures menu options
| Menu option |
Example setting |
Source of setting information |
| Enclosure location |
- Feature Code/Sequence Number = U789D-001
- Enclosure serial number = 00002FA
|
The label on the front of the CEC enclosure (at the
far right end, between the rack mounting screws, in a vertical orientation) |
- Click Save Settings. The service
processor might reboot at this point. Wait until the service processor
returns to Standby state before continuing with the next step.
- Return to the HMC repair process screen that sent you here
and click Next to continue.