FSPSP29

The system has detected that all I/O bridges are missing from the system configuration.

Before you begin

Note: Storage complex repair actions must always be managed from the management console. To replace any FRUs identified in this procedure, use Storage Facility Management > storage facility > Exchange Parts. If the FRUs are listed in this or another Serviceable Event, select them from there.

Procedure

  1. Replace the CEC enclosure service processor card using symbolic FRU SVCPROC.
  2. Perform a slow boot. See MAP4820 Performing a slow boot of a CEC enclosure.
  3. Does the problem persist?
    • Yes, continue with the next step.
    • No, this ends the procedure.
  4. Replace the CEC enclosure I/O backplane assembly using symbolic FRU SYSBKPL.
  5. Perform a slow boot. See MAP4820 Performing a slow boot of a CEC enclosure.

What to do next

This ends the procedure.