A problem has been encountered accessing the CEC enclosure VPD card or the
data found on the CEC enclosure has
been corrupted. This error occurred before VPD collection was completed,
so no location codes have been created.
Before you begin
Note: Storage complex repair actions must always be managed from the
management console. To replace any FRUs identified in this procedure, use . If the FRUs are listed in
this or another Serviceable Event, select them from there.
Procedure
- Replace the CEC enclosure VPD card, see Note above.
- Perform a slow boot. See MAP4820 Performing a slow boot of a CEC enclosure.
- Does the problem persist?
- Yes, continue with the next step.
- No, return to the procedure that sent you here. This
ends the procedure.
- Replace the
CEC enclosure service processor, see Note above.
- Perform a slow boot. See MAP4820 Performing a slow boot of a CEC enclosure.
- Does the problem persist?
- Yes, continue with the next step.
- No, return to the procedure that sent you here. This
ends the procedure.
- Replace the CEC enclosure I/O planar
assembly, see Note above.
- Perform a slow boot. See MAP4820 Performing a slow boot of a CEC enclosure.
- Does the problem persist?
- Yes, contact your next level of support. This ends the
procedure.
- No, this ends the procedure.