Exchange the UPS to CEC enclosure power supply cable
Before you begin
CAUTION:
This assembly contains mechanical moving parts. Use care when
you service this assembly. (C025)
Use approved ESD procedures to prevent damage.
Attention:
- This procedure is not a stand-alone procedure. Customer disruption and damage to the hardware might occur when microcode and power boundaries are not in the proper conditions for this service action.
- If a serviceable event FRU repair directed you to this procedure, the microcode and power boundaries are already set.
- If a serviceable event FRU repair did not direct you to this procedure, see MAP1230 Replace a FRU without using a serviceable event.
Note: All the cables and FRUs to be removed must be uniquely identified so they can be reinstalled
correctly.
Remove the UPS to CEC enclosure power supply cable
Procedure
Install the UPS to CEC enclosure power supply cable
Procedure
- Route and connect the new cable at both ends. Reinstall the cable retention.
- Exit this service information center parts exchange procedure and return to the procedure that sent you here.