FSPSP04
A problem is detected in the service processor firmware or I2C bus.
FSPSP04 Section-1: service processor firmware error
Procedure
- Does the serviceable event that
sent you here contain SRC B1xx2A33?
- Yes, exit this procedure and depending on the bundle level,
complete the following steps:
- For bundle levels below 8.0.1, close the serviceable event that
sent you here.
- Click Close in the current service information center window.
- One or more HMC repair screens might prompt you for the result of using the service procedure in the MAP. Select Problem fixed.
- Select No when asked whether you exchanged any parts.
- Select Yes when asked whether you isolated the problem.
- For bundle levels at 8.0.1 and above, continue with the next item
on the serviceable event FRU list.
- Click Close in the current service information center window.
- One or more HMC repair screens might prompt you for the result of using the service procedure in the MAP. Select Problem not fixed.
- Select No when asked whether you exchanged any parts.
- Select No when asked whether you isolated the problem.
- For bundle levels below 8.0.1, close the serviceable event that
sent you here.
- No, go to the next step.
- Yes, exit this procedure and depending on the bundle level,
complete the following steps:
- Does the serviceable event that sent you here contain one
of the following SRCs reference codes?
- B181850E - Platform firmware (0x81) reported an error
- B1818A1D - Building block registry read failure
- B181B00C - Error reading NVRAM entry
- B181B09C - Error writing NVRAM to VPD
- B181B09D - Mismatch in VPD versus NVRAM
- B181B09E - Failed to write System NVRAM values out to VPD
- B181B09F - Failed to write Enclosure NVRAM values out to VPD
- B181E40B - Detected NVRAM Recovered Errors
- B181FD02 - GARD Data did not exist because either it was the first IPL on this machine or NVRAM was cleared
- B7006950 - Platform LIC detected an error
- Yes, go to MAP6630 Recovering partition data on a CEC enclosure.
- No, go to the next step.
-
Are there any open serviceable
events with SRCs
BE190010 - BE190017?
- Yes, exit this procedure and repair any open serviceable events first.
- No, go to the next step.
- Is there an open serviceable event with SRC B1811404?
- Yes, go to FSPSP04 Section-2: I2C bus error.
- No, go to the next step.
- Do one or more of the following exist in the serviceable event that
sent you here?
- notificationType....=No Call Home or Customer Required - disabled by code update process.
- Symbolic FRU FSPSP06 exists in the FRU list (FSPSP06 says that the error is most likely a temporary error).
- No location code of the failing service processor is listed.
- You were using CDA to update code/firmware on this storage facility.
- Does the serviceable event FRU list
that sent you to this MAP contain any FRUs, other than the service
processor card, that are not replaced yet? Note: For the purposes of this step, a FRU is an actual part that appears in the serviceable event with a class of
FRU
. Items with a class ofIsolate procedure
orSymbolic procedure
are not FRUs.- Yes, exit this isolation procedure to replace the non-service processor card FRUs one at a time until the problem is resolved. If you cannot replace the FRU by selecting it in the FRU list, refer to MAP1230 Replace a FRU without using a serviceable event.
- No, there are no non-service processor card FRUs to be replaced, go to the next step.
- Are you going through this isolation
procedure for the first time?
- Yes, close this serviceable event and exit this isolation procedure. If there is a problem with the service processor firmware, a new serviceable event is opened.
- No, go to the next step.
- The error is assumed
to be in the service processor firmware. There is no DS8000® service
representative procedure to reload the same level of firmware on the CEC enclosure service processor. Instead,
replace the service processor;
go to MAP1215 Replace a FRU.
If the problem is not fixed, go to FSPSP04 Section-2: I2C bus error.
FSPSP04 Section-2: I2C bus error
About this task
Procedure
- Using the Exchange Parts menu, replace
the following FRUs in turn until the problem is resolved:
- The CEC enclosure control panel.
- If the problem still exists, does the control panel display
a bouncing ball icon after you replace the Op Panel?
- Yes, go to MAP2220 Section-4.
- No, go to the next FRU.
- The CEC enclosure I/O backplane assembly.
- RPC1 card.
- RPC2 card.
- The CEC enclosure service processor card.
- The CEC enclosure power supplies.
- This ends the procedure.