SRNs 60B-xxx through 6C9-600
This section lists the SRNs 60B-xxx through 6C9-600.
| Service Request Number | Failing Function Codes | Description/Action |
|---|---|---|
| 601-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 60B-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 613-xxx | 613 | An 8-mm 80-GB VXA-2 tape device problem has occurred. Action: Use MAP0210 General problem resolution. |
| 61B-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 61D-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 61E-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 621-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 623-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 624-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 62D-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 62E-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 636-101 | 636 | EPROM test failure. Action: Use MAP0210 General problem resolution. |
| 636-102 | 636 | Adapter SDRAM failure. Action: Use MAP0210 General problem resolution. |
| 636-103 | 636 | Adapter checksum failure. Action: Use MAP0210 General problem resolution. |
| 636-104 | 636 | Adapter memory test failure. Action: Use MAP0210 General problem resolution. |
| 636-105 | 636 | Adapter buffer test failure. Action: Use MAP0210 General problem resolution. |
| 636-106 | 636 | Adapter cache test failure. Action: Use MAP0210 General problem resolution. |
| 636-107 | 636 | Internal loop-back test failure. Action: Use MAP0210 General problem resolution. |
| 636-108 | 636 | External wrap test failure. Action: Use MAP0210 General problem resolution. |
| 636-109 | 221 | Enhanced error handling failure on the bus. Action: Use MAP0210 General problem resolution. |
| 636-110 | 221 | Enhanced error handling failure on the Eads chip. Action: Use MAP0210 General problem resolution. |
| 636-111 | 636 | Enhanced error handling failure on the adapter. Action: Use MAP0210 General problem resolution. |
| 636-201 | 636
221 |
Hardware failure opening adapter. Action: Use MAP0210 General problem resolution. |
| 636-202 | 636
221 |
Interrupt test failure. Action: Use MAP0210 General problem resolution. |
| 636-203 | 636
221 |
Adapter DMA test failure. Action: Use MAP0210 General problem resolution. |
| 636-204 | 636
221 |
Enhanced error handling failure opening the adapter. Action: Use MAP0210 General problem resolution. |
| 636-701 | 636 | ELA indicates an I/O failure on the adapter. Action: Use MAP0210 General problem resolution. |
| 638-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 639-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 63A-xxx to 63F-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 640-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 643-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 644-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 646-101 | D46 | External Test Failure. Action: Use MAP0210 General problem resolution. |
| 646-102 | 240 | External Test Failure. Action: Use MAP0210 General problem resolution. |
| 646-103 | 646 | I/O Test Failure. Action: Use MAP0210 General problem resolution. |
| 646-104 | 646
221 |
Adapter On-card Test Failure. Action: Use MAP0210 General problem resolution. |
| 646-105 | 646 | Wrap Test Failure. Action: Use MAP0210 General problem resolution. |
| 646-106 | 646 | Enhanced Error Handling failure on bus. Action: Use MAP0210 General problem resolution. |
| 646-107 | 646 | EEH failure on PCI-PCI bridge chip. Action: Use MAP0210 General problem resolution. |
| 646-108 | 646 | Enhanced Error Handling failure on adapter. Action: Use MAP0210 General problem resolution. |
| 646-201 | 646
221 |
Configuration Register Test Failure. Action: Use MAP0210 General problem resolution. |
| 646-202 | 646
221 |
Wrap Test Failure. Action: Use MAP0210 General problem resolution. |
| 646-204 | D46
240 |
External Test Failure. Action: Use MAP0210 General problem resolution. |
| 646-205 | D46
646 |
External Test Failure. Action: Run advanced diagnostics with wrap test for this resource to obtain a correct problem resolution. |
| 646-206 | 240
646 |
External Test Failure. Action: Run advanced diagnostics with wrap test for this resource to obtain a correct problem resolution. |
| 646-302 | 240
D46 221 |
External Test Failure. Action: Run advanced diagnostics with wrap test for this resource to obtain a correct problem resolution. |
| 646-303 | 646
D46 221 |
External Test Failure. Action: Run advanced diagnostics with wrap test for this resource to obtain a correct problem resolution. |
| 646-401 | 240
646 D46 221 |
External Test Failure. Action: Run advanced diagnostics with wrap test for this resource to obtain a correct problem resolution. Action: Use MAP0210 General problem resolution. |
| 646-701 | 646 | Error log analysis indicates that an adapter error has occurred. Action: Use MAP0210 General problem resolution. |
| 646-702 | 646 | Error log analysis indicates that an adapter check has occurred. Action: Use MAP0210 General problem resolution. |
| 646-703 | 646
221 |
Error log analysis indicates that a DMA failure has occurred. Action: Use MAP0210 General problem resolution. |
| 646-704 | 646
221 |
Error log analysis indicates that a PCI Bus error has occurred. Action: Use MAP0210 General problem resolution. |
| 646-705 | 646
221 |
Error log analysis indicates that a Programmed I/O error has occurred. Action: Use MAP0210 General problem resolution. |
| 646-706 | 646 | ELA indicates a command write failure occurred. Action: Use MAP0210 General problem resolution. |
| 646-707 | 646 | ELA indicates an internal adapter error has occurred. Action: Use MAP0210 General problem resolution. |
| 64A-xxx to 64F-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 650-xxx | 650 | Disk drive configuration failed. Action: Use MAP0210 General problem resolution. |
| 653-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 657-001 | software
657 |
Software error. Action: Use MAP0210 General problem resolution. |
| 657-002 | software
655 |
Adapter failure. Action: Use MAP0210 General problem resolution. |
| 657-003 | 657
227 |
Adapter failure. Action: Use MAP0210 General problem resolution. |
| 657-004 | 657
Monitor/Cable |
Display failure. Action: Use MAP0210 General problem resolution. |
| 657-005 | 657
227 Monitor/Cable |
Adapter failure. Action: Use MAP0210 General problem resolution. |
| 65A-xxx to 65F-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 662-101 | 221 | Enhanced error handling failure on the bus. Action: Use MAP0210 General problem resolution. |
| 662-102 | 293 | Enhanced error handling failure on a PCI-PCI Bridge. Action: Use MAP0210 General problem resolution. |
| 662-103 | 662
221 |
Enhanced error handling failure on the adapter. Action: Use MAP0210 General problem resolution. |
| 662-212 | 662 | FIFO empty bit set. Action: Use MAP0210 General problem resolution. |
| 662-213 | 662 | FIFO empty bit clear. Action: Use MAP0210 General problem resolution. |
| 662-214 | 662 | FIFO full bit set. Action: Use MAP0210 General problem resolution. |
| 662-215 | 662 | FIFO full bit clear. Action: Use MAP0210 General problem resolution. |
| 662-216 | 662 | FIFO data miscompare. Action: Use MAP0210 General problem resolution. |
| 662-217 | 662 | SCSI FIFO data miscompare. Action: Use MAP0210 General problem resolution. |
| 662-218 | 662 | SCSI FIFO underflow. Action: Use MAP0210 General problem resolution. |
| 662-219 | SCSI parity error. Action: Go to MAP0050 SCSI bus problems. |
|
| 662-220 | 662 | SCSI FIFO flags error. Action: Use MAP0210 General problem resolution. |
| 662-221 | 662
221 |
Miscompare during the write/read of the configuration register. Action: Use MAP0210 General problem resolution. |
| 662-222 | 662 | Error during the write/read of the memory register. Action: Use MAP0210 General problem resolution. |
| 662-223 | 662 | Miscompare during the write/read of the memory I/O register. Action: Go to MAP0050 SCSI bus problems. |
| 662-224 | 662
221 |
SCSI configuration register read or write error. Action: Use MAP0210 General problem resolution. |
| 662-225 | 662 | Adapter POST failed. Action: Use MAP0210 General problem resolution. |
| 662-226 | SCSI wrap or PTC failure. Action: Go to MAP0050 SCSI bus problems. |
|
| 662-227 | 662
221 |
SCSI adapter test failure. Action: Use MAP0210 General problem resolution. |
| 662-230 | Arbitration test failed. Action: Go to MAP0050 SCSI bus problems. |
|
| 662-231 | Function could not complete. Action: Go to MAP0050 SCSI bus problems. |
|
| 662-232 | SCSI bus data miscompare. Action: Go to MAP0050 SCSI bus problems. |
|
| 662-240 | No terminal power. Action: Go to MAP0050 SCSI bus problems. |
|
| 662-242 | SCSI bus problem. Action: Go to MAP0050 SCSI bus problems. |
|
| 662-301 | 662
221 |
The parent device open failed. Action: Use MAP0210 General problem resolution. |
| 662-701 | 662 | Error log analysis indicates a PCI SCSI adapter failure. Action: Use MAP0210 General problem resolution. |
| 662-801 | Error log analysis indicates a terminator problem. Action: Run the diagnostics on the adapter in system verification mode. If an SRN is reported, use the SRN to resolve the problem. If an SRN is not reported, use the SCSI service hints in General SCSI Configuration Checks to resolve the problem. |
|
| 662-802 | Error log analysis indicates that multiple attempts to reset the SCSI bus have timed out. Action: Run the diagnostics on the adapter in system verification mode. If an SRN is reported, use the SRN to resolve the problem. If an SRN is not reported, use the SCSI service hints in General SCSI Configuration Checks to resolve the problem. |
|
| 662-803 | Error log analysis indicates that multiple SCSI bus errors have occurred. Action: Run the diagnostics on the adapter in system verification mode. If an SRN is reported, use the SRN to resolve the problem. If an SRN is not reported, use the SCSI service hints in General SCSI Configuration Checks to resolve the problem. |
|
| 663-101 | 663
C94 C95 |
IBM ARTIC960RxD or RxF PCI Adapter Central Processing Unit test failure. Action: Use MAP0210 General problem resolution. |
| 663-102 | 663
C94 C95 |
IBM ARTIC960RxD or RxF PCI Adapter Timer test failure. Action: Use MAP0210 General problem resolution. |
| 663-103 | 663
C94 C95 |
IBM ARTIC960RxD or RxF PCI Adapter Bus Interface test failure. Action: Use MAP0210 General problem resolution. |
| 663-104 | 663
C94 C95 |
IBM ARTIC960RxD or RxF PCI Adapter Dynamic Random Access Memory test failure. Action: Use MAP0210 General problem resolution. |
| 663-105 | 663
C94 C95 |
IBM ARTIC960RxD or RxF PCI Adapter Memory Protection test failure. Action: Use MAP0210 General problem resolution. |
| 663-106 | 663
C94 C95 |
IBM ARTIC960RxD PCI Adapter Debug Port test failure. Action: Use MAP0210 General problem resolution. |
| 663-107 | C95
663 C97 |
Interface board wrap test failure. Action: Use MAP0210 General problem resolution. |
| 663-110 | C94
663 C95 |
IBM ARTIC960RxD or RxF PCI Adapter Download Diagnostics test failure. Action: Use MAP0210 General problem resolution. |
| 663-123 | C95
663 C97 |
Interface board non-wrap test failure. Action: Use MAP0210 General problem resolution. |
| 663-150 | 663
software 227 |
Device configuration failure. Action: Use MAP0210 General problem resolution. |
| 663-151 | 663
software 227 |
Device driver indicates a hardware failure. Action: Use MAP0210 General problem resolution. |
| 663-152 | 663 | Failure and error in determining which type of IBM ARTIC960RxD PCI Adapter. Action: Use MAP0210 General problem resolution. |
| 663-153 | 663
227 C94 software |
Error log analysis indicates an IBM ARTIC960RxD or RxF PCI Adapter failure.
Action: Use the errpt command to check error log. Action: Use MAP0210 General problem resolution. |
| 663-154 | C94
663 C95 |
IBM ARTIC960RxD or RxF PCI Adapter initialization failure. Action: Use MAP0210 General problem resolution. |
| 663-155 | C94
663 C95 |
IBM ARTIC960RxD or RxF PCI Adapter initialization failure. Action: Use MAP0210 General problem resolution. |
| 663-156 | C94
663 C95 |
IBM ARTIC960RxD or RxF PCI Adapter initialization failure. Action: Use MAP0210 General problem resolution. |
| 663-157 | C98
C97 C95 |
Cable wrap test failure. Action: Use MAP0210 General problem resolution. |
| 669-101 | 221 | Enhanced error handling failure on bus. Action: Use MAP0210 General problem resolution. |
| 669-102 | 221 | Enhanced error handling failure on Eads chip. Action: Use MAP0210 General problem resolution. |
| 669-103 | 669 | Enhanced error handling failure on adapter. Action: Use MAP0210 General problem resolution. |
| 669-201 | 669
221 |
Configuration register test failure. Action: Before going to MAP 210, look at the label on the adapter. If the label is A-A, use SRN 66C-201 instead, and go to MAP0210 General problem resolution. |
| 669-202 | 669 | I/O register test failure. Action: Use MAP0210 General problem resolution. |
| 669-203 | 669 | Adapter memory test failure. Action: Use MAP0210 General problem resolution. |
| 669-204 | 669 | Adapter initialization test failure. Action: Use MAP0210 General problem resolution. |
| 669-205 | 669 | Internal loopback test failure. Action: Use MAP0210 General problem resolution. |
| 669-206 | 669 | External wrap test failure (1000 Mbps). Action: Use MAP0210 General problem resolution. |
| 669-701 | 669 | Error Log Analysis indicates that this device failed to initialize because it is not the IBM version of this adapter. AIX operating system cannot configure this non-IBM version of the adapter. Action: Use MAP0210 General problem resolution. |
| 669-702 | 669 | Error Log Analysis indicates that this device failed to initialize due to a problem with the EEPROM on the adapter. Action: Use MAP0210 General problem resolution. |
| 669-703 | Error Log Analysis indicates that this device has failed to initialize due to a self-test failure. Action: Use MAP0210 General problem resolution. |
|
| 669-704 | Error Log Analysis indicates that this device has failed to initialize due to firmware download error. Action: Use MAP0210 General problem resolution. |
|
| 66A-101 | Diagnostics indicates adapter configuration failure. Action: Use MAP0210 General problem resolution. |
|
| 66C-101 | 221 | Enhanced error handling failure on bus. Action: Use MAP0210 General problem resolution. |
| 66C-102 | 221 | Enhanced error handling failure on Eads chip. Action: Use MAP0210 General problem resolution. |
| 66C-103 | 66C | Enhanced error handling failure on adapter. Action: Use MAP0210 General problem resolution. |
| 66C-201 | 66C
221 |
Configuration register test failure. Action: Use MAP0210 General problem resolution. |
| 66C-202 | 66C | I/O register test failure. Action: Use MAP0210 General problem resolution. |
| 66C-203 | 66C | Adapter memory test failure. Action: Use MAP0210 General problem resolution. |
| 66C-204 | 66C | Adapter initialization test failure. Action: Use MAP0210 General problem resolution. |
| 66C-205 | 66C | Internal loopback test failure. Action: Use MAP0210 General problem resolution. |
| 66C-206 | 66C | External wrap test failure (1000 Mbps). Action: Use MAP0210 General problem resolution. |
| 66C-207 | 66C | External wrap test failure (10 Mbps). Action: Use MAP0210 General problem resolution. |
| 66C-208 | 66C | External wrap test failure (100 Mbps). Action: Use MAP0210 General problem resolution. |
| 66C-702 | 66C | Error Log Analysis indicates that this device failed to initialize due to a problem with the EEPROM on the adapter. Action: Use MAP0210 General problem resolution. |
| 66C-703 | 66C | Error Log Analysis indicates that this device has failed to initialize due to a self-test failure. Action: Use MAP0210 General problem resolution. |
| 66C-704 | 66C | Error Log Analysis indicates that this device has failed to initialize due to firmware download error. Action: Use MAP0210 General problem resolution. |
| 66D-101 | 66D
227 |
The PCI wrap test failed. Action: Use MAP0270 SCSI RAID problem resolution and verification. |
| 66D-102 | 66D
E2A |
The POST indicates an adapter failure. Action: Use MAP0270 SCSI RAID problem resolution and verification. |
| 66D-103 | 66D | The POST indicates an adapter channel failure. Action: Use MAP0270 SCSI RAID problem resolution and verification. |
| 66D-104 | 190
B3A |
The POST indicates a defective cable. Action: Use MAP0210 General problem resolution. |
| 66D-105 | 722 | The POST indicates a defective backplane or external enclosure. Action: Use MAP0210 General problem resolution. |
| 66D-106 | 722 | The POST indicates the last disk drive reconnected caused a channel failure.
Action: Use MAP0270 SCSI RAID problem resolution and verification. |
| 66D-108 | 221 | Enhanced error handling failure on bus. Action: Use MAP0210 General problem resolution. |
| 66D-109 | 66D | The test indicates an adapter failure. Action: Use MAP0270 SCSI RAID problem resolution and verification. |
| 66D-110 | 722 | The disk reported a Predictive Failure Analysis error (PFA). Action: Use MAP0270 SCSI RAID problem resolution and verification. |
| 66D-111 | 722 | The disk drive has been failed by the adapter. Action: Use MAP0270 SCSI RAID problem resolution and verification. |
| 66D-112 | 722 | ELA indicates that the disk reported a hard data error. Action: Use MAP0270 SCSI RAID problem resolution and verification. |
| 66D-113 | 722 | ELA indicates that the disk reported a hard equipment error. Action: Use MAP0270 SCSI RAID problem resolution and verification. |
| 66D-114 | E2A | ELA indicates a cache failure. Action: Use MAP0270 SCSI RAID problem resolution and verification. |
| 66D-115 | E3A | ELA indicates that the cache battery is either low on power or has failed.
Action: Use MAP0270 SCSI RAID problem resolution and verification. |
| 66D-116 | 66D | Failed to disable data scrub. Action: Use MAP0270 SCSI RAID problem resolution and verification. |
| 66D-117 | E2A | POST indicates cache failure. Action: Use MAP0270 SCSI RAID problem resolution and verification. |
| 66D-118 | E2A | Adapter test indicates a cache failure. Action: Use MAP0270 SCSI RAID problem resolution and verification. |
| 66D-119 | E2A | Adapter test indicates that write cache is missing. Action: Use MAP0270 SCSI RAID problem resolution and verification. |
| 66D-120 | E2A | Adapter test indicates that cache size is invalid. Action: Use MAP0270 SCSI RAID problem resolution and verification. |
| 66D-121 | E3A | Adapter test indicates that the cache battery is low on power. Action: Use MAP0270 SCSI RAID problem resolution and verification. |
| 66D-122 | 66D | Adapter test indicates cache battery failure. Action: Use MAP0270 SCSI RAID problem resolution and verification. |
| 66D-123 | 221 | ELA indicates an adapter failure. Action: Use MAP0270 SCSI RAID problem resolution and verification. |
| 66D-124 | 221 | Enhanced error handling failure on PCI-PCI Bridge. Action: Use MAP0210 General problem resolution. |
| 66D-125 | 66D
221 |
Enhanced error handling failure on adapter. Action: Use MAP0210 General problem resolution. |
| 66D-400 | 66D
190 B3A 722 |
The POST test indicates a channel failure. Action: Use MAP0270 SCSI RAID problem resolution and verification. |
| 66D-701 | 66D
221 |
Error Log Analysis indicates an enhanced error handling error. Action: Use MAP0210 General problem resolution. |
| 66E-100 | 66E | Unable to configure the parent device. Action: Use MAP0210 General problem resolution. |
| 66E-102 | 66E | SCSI command Inquiry has failed. Unable to get Additional Vital Product Data. Action: Use MAP0210 General problem resolution. |
| 66E-103 | 66E | SCSI command Reserve has failed. Action: Use MAP0210 General problem resolution. |
| 66E-104 | 66E | SCSI command Mode Sense has failed. Action: Use MAP0210 General problem resolution. |
| 66E-105 | 66E | SCSI command Mode Select has failed. Action: Use MAP0210 General problem resolution. |
| 66E-106 | 66E | SCSI command Allow Media Removal has failed. Action: Use MAP0210 General problem resolution. |
| 66E-107 | 66E | SCSI command Prevent Media Removal has failed. Action: Use MAP0210 General problem resolution. |
| 66E-108 | 66E | SCSI command Start Stop Unit has failed. Action: Use MAP0210 General problem resolution. |
| 66E-109 | 66E | SCSI command Test Unit Ready has failed. Action: Use MAP0210 General problem resolution. |
| 66E-10A | 66E | SCSI command Send Diagnostic has failed. Action: Use MAP0210 General problem resolution. |
| 66E-10B | 66E | SCSI command Release has failed. Action: Use MAP0210 General problem resolution. |
| 66E-10F | 66E | Undetermined hardware error has occurred. Action: Use MAP0210 General problem resolution. |
| 66E-200 | 66E
B88 |
Unable to configure the device. Action: Use MAP0210 General problem resolution. |
| 66E-201 | media
66E |
DVD-RAM drive is unable to eject the tray. Action: Verify that no external object prevents the drive from ejecting the tray. Verify that no media is stuck inside the drive. Otherwise, use MAP0210 General problem resolution. |
| 66E-202 | media
66E |
DVD-RAM drive is unable to load the tray. Action: Verify that no external object prevents the drive from ejecting the tray. Verify that no media is stuck inside the drive. Otherwise, use MAP0210 General problem resolution. |
| 66E-203 | media
66E |
DVD-RAM drive is unable to detect the test medium. Action: Verify that no external object prevents the drive from ejecting the tray. Verify that no media is stuck inside the drive. Otherwise, use MAP0210 General problem resolution. |
| 66E-204 | 66E
B88 |
A SCSI reservation conflict has occurred. Action: Use MAP0210 General problem resolution. |
| 66E-205 | media
66E |
The Random Write/Read/Compare Test has detected a medium error while testing the DVD-RAM test medium. Action: Run Diagnostic on this drive with another DVD-RAM test medium. Use MAP0210 General problem resolution. |
| 66E-206 | media
66E |
The Random Write/Read/Compare Test has detected a hardware error while testing the DVD-RAM test medium. Action: Run Diagnostic on this drive with another DVD-RAM test medium. Use MAP0210 General problem resolution. |
| 66E-207 | media
66E |
The Random Read Test has detected a medium error while testing the CD-ROM test medium. Action: Run Diagnostic on this drive with another DVD-RAM test medium. Use MAP0210 General problem resolution. |
| 66E-208 | media
66E |
The Random Read Test has detected a hardware error while testing the CD-ROM test medium. Action: Run Diagnostic on this drive with another DVD-RAM test medium. Use MAP0210 General problem resolution. |
| 66E-209 | media
66E |
DVD-RAM drive is unable to determine the media type. Action:
|
| 66E-20A | media
66E |
DVD-RAM drive has faulty write-protect-detection mechanism. Action:
|
| 66E-20B | media
66E |
DVD-RAM drive has detected a media error. Action:
|
| 66E-300 | 66E
B88 190 |
SCSI command timeout has occurred. Action: Use MAP0210 General problem resolution to replace the defective DVD-ROM drive. |
| 66E-301 | 66E
B88 190 |
Unit Attention has occurred. Action: Use MAP0210 General problem resolution. |
| 66E-700 | 66E | ELA indicates an irrecoverable hardware error. Action: Use MAP0210 General problem resolution. |
| 66E-701 | 66E | ELA indicates an undetermined hardware error. Action: Use MAP0210 General problem resolution. |
| 670-xxx to 673-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 674-101 | 674
C94 C95 |
IBM ARTIC960Rx PCI Adapter Central Processing Unit (CPU) test failure. Action: Use MAP0210 General problem resolution. |
| 674-102 | 674
C94 C95 |
IBM ARTIC960Rx PCI Adapter Timer test failure. Action: Use MAP0210 General problem resolution. |
| 674-103 | 674
C94 C95 |
IBM ARTIC960Rx PCI Adapter Bus Interface test failure. Action: Use MAP0210 General problem resolution. |
| 674-104 | 674
C94 C95 |
IBM ARTIC960Rx PCI Adapter Dynamic Random Access Memory (DRAM) test failure. Action: Use MAP0210 General problem resolution. |
| 674-105 | 674
C94 C95 |
IBM ARTIC960Rx PCI Adapter Memory Protection test failure. Action: Use MAP0210 General problem resolution. |
| 674-106 | 674
C94 C95 |
IBM ARTIC960Rx PCI Adapter Debug Port test failure. Action: Use MAP0210 General problem resolution. |
| 674-107 | 674
C94 C95 |
Interface board wrap test failure. Action: Use MAP0210 General problem resolution. |
| 674-110 | 674
C94 C95 |
IBM ARTIC960Rx PCI Adapter Download Diagnostics test failure. Action: Use MAP0210 General problem resolution. |
| 674-123 | C94
C95 |
Interface board non-wrap test failure. Action: Use MAP0210 General problem resolution. |
| 674-150 | 674
software 227 |
Device configuration failure. Action: Use MAP0210 General problem resolution. |
| 674-151 | 674
software 227 |
Device driver indicates a hardware failure. Action: Use MAP0210 General problem resolution. |
| 674-152 | 674 | Failure and error in determining which type of IBM ARTIC960Rx PCI Adapter. Action: Use MAP0210 General problem resolution. |
| 674-153 | 674
software C94 227 |
Error log analysis indicates an IBM ARTIC960Rx PCI Adapter failure. Action:
Use the errpt command to check error log. Action: Use MAP0210 General problem resolution. |
| 674-154 | C94
674 C95 |
IBM ARTIC960Rx PCI Adapter initialization failure. Action: Use MAP0210 General problem resolution. |
| 674-155 | C94
674 C95 |
IBM ARTIC960Rx PCI Adapter initialization failure. Action: Use MAP0210 General problem resolution. |
| 674-156 | C94
674 C95 |
IBM ARTIC960Rx PCI Adapter initialization failure. Action: Use MAP0210 General problem resolution. |
| 674-157 | C94
674 C95 |
Cable wrap test failure. Action: Use MAP0210 General problem resolution. |
| 675-101 | C94
674 C95 |
IBM ARTIC960Hx Adapter Central Processing Unit (CPU) test failure. Action: Use MAP0210 General problem resolution. |
| 675-102 | C94
674 C95 |
IBM ARTIC960Hx Adapter Timer test failure. Action: Use MAP0210 General problem resolution. |
| 675-103 | C94
674 C95 |
IBM ARTIC960Hx Adapter Bus Interface test failure. Action: Use MAP0210 General problem resolution. |
| 675-104 | C94
674 C95 |
IBM ARTIC960Hx Adapter Dynamic Random Access Memory (DRAM) test failure. Action: Use MAP0210 General problem resolution. |
| 675-105 | C94
674 C95 |
IBM ARTIC960Hx Adapter Memory Protection test failure. Action: Use MAP0210 General problem resolution. |
| 675-106 | C94
674 C95 |
IBM ARTIC960Hx Adapter Debug Port test failure. Action: Use MAP0210 General problem resolution. |
| 675-107 | C94
674 C95 |
Interface board wrap test failure. Action: Use MAP0210 General problem resolution. |
| 675-110 | C94
674 C95 |
IBM ARTIC960Hx Adapter Download Diagnostics test failure. Action: Use MAP0210 General problem resolution. |
| 675-123 | C94
674 C95 |
Interface board non-wrap test failure. Action: Use MAP0210 General problem resolution. |
| 675-150 | 675
software 227 |
Device configuration failure. Action: Use MAP0210 General problem resolution. |
| 675-151 | 675
software 227 |
Device driver indicates a hardware failure. Action: Use MAP0210 General problem resolution. |
| 675-152 | 675 | Failure and error in determining which type of IBM ARTIC960Hx Adapter. Action: Use MAP0210 General problem resolution. |
| 675-153 | 675
software C94 227 |
Error log analysis indicates an IBM ARTIC960Hx Adapter failure. Action: Use the errpt command to check error log. MAP0210 General problem resolution. |
| 675-154 | C94
675 C95 |
IBM ARTIC960Hx Adapter initialization failure. Action: Use MAP0210 General problem resolution. |
| 675-155 | C94
675 C95 |
IBM ARTIC960Hx Adapter initialization failure. Action: Use MAP0210 General problem resolution. |
| 675-156 | C94
675 C95 |
IBM ARTIC960Hx Adapter initialization failure. Action: Use MAP0210 General problem resolution. |
| 675-157 | C94
675 C95 |
Cable wrap test failure. Action: Use MAP0210 General problem resolution. |
| 677-101 | 677 | The Fibre Channel Adapter configuration failed. Action: Use MAP0210 General problem resolution. |
| 677-102 | 677 | The Reset test failed. Action: Use MAP0210 General problem resolution. |
| 677-103 | 677 | The Register test failed. Action: Use MAP0210 General problem resolution. |
| 677-104 | 677 | The SRAM test failed. Action: Use MAP0210 General problem resolution. |
| 677-105 | 677 | The Internal Wrap test failed. Action: Use MAP0210 General problem resolution. |
| 677-106 | 677 | The Gigabaud Link Module (GLM) Wrap Test Failure. Action: Use the MAP0210 General problem resolution The External Wrap test failed. Action: Use the MAP0210 General problem resolution. |
| 677-107 | 677 | The External Wrap test failed. Action: Use the MAP0210 General problem resolution. |
| 677-109 | 221 | Enhanced Error Handling Failure on EADs chip. Action: Use the MAP0210 General problem resolution. |
| 677-110 | 677 | Enhanced Error Handling Failure on adapter. Action: Use the MAP0210 General problem resolution. |
| 677-201 | 677
221 |
The Configuration Register test failed. Action: Use the MAP0210 General problem resolution. |
| 677-202 | 677
221 |
The Interrupt test failed. Action: Use MAP0210 General problem resolution. |
| 677-203 | 677
221 |
The PCI Wrap test failed. Action: Use MAP0210 General problem resolution. |
| 677-204 | 677
221 |
The DMA test failed. Action: Use MAP0210 General problem resolution. |
| 677-205 | 677
221 |
I/O error on a read/write operation. Action: Use MAP0210 General problem resolution. |
| 677-701 | 677
221 |
Error log analysis indicates that an error has occurred with the adapter. Action: Use the MAP0210 General problem resolution. |
| 677-703 | 677 | Error log analysis indicates that an unknown adapter error has occurred. Action: Use the MAP0210 General problem resolution. |
| 677-704 | 677 | Error log analysis indicates that an adapter error has occurred. Action: Use MAP0210 General problem resolution. |
| 677-705 | 677 | A parity error has been detected. The adapter must be replaced immediately. Failure to do so could result in data being read or written incorrectly. Action: Use MAP0210 General problem resolution. |
| 677-706 | 677 | A fatal hardware error has occurred. This adapter was successfully taken offline. It will remain offline until reconfigured or the system is rebooted. This adapter must be replaced and not brought back online. Failure to adhere to this action could result in data being read or written incorrectly or in the loss of data. |
| 678-098 | 678 | Tape drive indicates an error. Action: Use MAP0210 General problem resolution. |
| 678-099 | 678
B88 |
Tape drive not found. Action: Use MAP0210 General problem resolution. |
| 678-101 | 678 | Timeout while attempting to communicate with SCSI device. Action: Use MAP0210 General problem resolution. |
| 678-102 | 678 | e SCSI device indicates busy. Action: Use MAP0210 General problem resolution. |
| 678-103 | 678 | The SCSI device indicates a reservation conflict. Action: Use MAP0210 General problem resolution. |
| 678-104 | 678 | The SCSI device indicates a check condition. Action: Use MAP0210 General problem resolution. |
| 678-105 | 678 | An error is detected in request sense data. Action: Use MAP0210 General problem resolution. |
| 678-107 | 678 | Sense data from the SCSI drive has unexpected data. Action: Use MAP0210 General problem resolution. |
| 678-110 | 678 | The Reserve command failed. Action: Use MAP0210 General problem resolution. |
| 678-111 | 678 | Invalid condition from the drive after a reserve. Action: Use MAP0210 General problem resolution. |
| 678-112 | 678 | The write-protect sensor test failed. Action: Use MAP0210 General problem resolution. |
| 678-113 | 678 | Invalid condition from drive after a request sense. Action: Use MAP0210 General problem resolution. |
| 678-114 | 678 | Timeout while attempting to communicate with the SCSI device. Action: Use MAP0210 General problem resolution. |
| 678-120 | 678 | The Inquiry command failed. Action: Use MAP0210 General problem resolution. |
| 678-130 | 678
media |
Load command failed. Action: Use MAP0210 General problem resolution. |
| 678-134 | B88
software |
The adapter failed to configure. Action: Use MAP0210 General problem resolution. |
| 678-135 | 678
media |
The Unload command failed. Action: Use MAP0210 General problem resolution. |
| 678-140 | 678 | The Mode Select command failed. Action: Use MAP0210 General problem resolution. |
| 678-150 | 678
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution. |
| 678-160 | 678
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution. |
| 678-161 | 678
B88 |
Invalid condition from the drive after a reserve. Action: Use MAP0210 General problem resolution. |
| 678-163 | 678
B88 |
Invalid condition from the drive after a request sense. Action: Use MAP0210 General problem resolution. |
| 678-164 | 678
B88 |
Timeout while attempting to communicate with the SCSI device. Action: Use MAP0210 General problem resolution. |
| 678-165 | 678
B88 276 |
Write, Read and Compare Test failed. Action: Use MAP0210 General problem resolution. |
| 678-166 | 678
B88 software |
Unable to configure the device. Action: Use MAP0210 General problem resolution. |
| 678-167 | 678
B88 |
An unexpected SCSI error occurred. Action: Use MAP0210 General problem resolution. |
| 678-168 | B88
software |
The adapter failed to configure. Action: Use MAP0210 General problem resolution. |
| 678-169 | 678
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution. |
| 678-170 | 678
B88 media |
The Read, Write and Compare test failed. Action: Use MAP0210 General problem resolution. |
| 678-180 | 678
media |
The Load command failed. Action: Use MAP0210 General problem resolution. |
| 678-185 | 678
media |
The Unload command failed. Action: Use MAP0210 General problem resolution |
| 678-190 | 678 | The Mode Select command failed. Action: Use MAP0210 General problem resolution |
| 678-200 | 678
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution |
| 678-201 | 678
B88 |
Error diagnosed from error log analysis. Action: Use MAP0210 General problem resolution. |
| 678-210 | 678
B88 |
The device configuration failed. Action: Use MAP0210 General problem resolution |
| 678-211 | 678
B88 |
The device open failed. Action: Use MAP0210 General problem resolution |
| 678-220 | 678 | The Release command failed. Action: Use MAP0210 General problem resolution |
| 678-230 | 678 | The Request Sense command failed. Action: Use MAP0210 General problem resolution |
| 678-240 | 678 | The Openx command failed. Action: Use MAP0210 General problem resolution |
| 678-260 | 678 | The device configuration failed. Action: Use MAP0210 General problem resolution. |
| 678-261 | 678 | The device open failed. Action: Use MAP0210 General problem resolution |
| 678-300 | 678
software |
The device configuration failed. Action: Use MAP0210 General problem resolution. |
| 678-310 | 678
B88 software |
SCSI adapter configuration failed. Action: Use MAP0210 General problem resolution. |
| 678-320 | 678
media |
Error log analysis indicates a failure. Action: Use MAP0210 General problem resolution. |
| 678-411 to 678-423 | 678
B88 software |
A reservation conflict occurred. Action: Use MAP0210 General problem resolution. |
| 678-511 to 678-523 | 678
B88 |
The drive returned bad or non-extended sense data. Action: Use MAP0210 General problem resolution. |
| 678-611 to 678-623 | 678
B88 software |
An adapter or bus I/O error occurred. Action: Use MAP0210 General problem resolution. |
| 678-711 to 678-723 | 678
B88 software |
A device timeout error occurred. Action: Use MAP0210 General problem resolution. |
| 679-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 67B-100 | 67B | POST failed: Catastrophic error detected. Action: Use MAP0210 General problem resolution. |
| 67B-601 | 11A | ELA indicates a low battery warning. Action: Use MAP0210 General problem resolution. |
| 67B-602 | 67B | ELA indicates a mesh violation - tamper. Action: Use MAP0210 General problem resolution. |
| 67B-603 | 67B | ELA indicates the coprocessor is held in a reset condition. Action: Use MAP0210 General problem resolution. |
| 67B-604 | 67B | ELA indicates a +3, +5, or +12 V over-voltage condition. Action: Use MAP0210 General problem resolution. |
| 67B-605 | 67B | ELA indicates an out-of-temperature specification. Action: Use MAP0210 General problem resolution. |
| 67B-606 | 67B | ELA indicates a X-ray or dead battery condition. Action: Use MAP0210 General problem resolution. |
| 67B-607 | 67B | ELA indicates: Intrusion latch. Action: Use MAP0210 General problem resolution. |
| 67E-001 | 67E
221 Monitor/Cable |
Adapter problem. Action: Use MAP0210 General problem resolution. |
| 67E-002 | 67E
Monitor/Cable |
Display problem. Action: Use MAP0210 General problem resolution. |
| 67E-003 | 67E
software |
Software error. Action: Use MAP0210 General problem resolution. |
| 67E-004 | 67E
221 Monitor/Cable |
The monitor test failed. Action: Use MAP0210 General problem resolution. |
| 681-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 682-111 | 682
B88 |
Unable to reserve device. Action: Use MAP0210 General problem resolution. |
| 682-112 | 682
B88 |
Unable to do configuration. Action: Use MAP0210 General problem resolution. |
| 682-113 | 682
B88 |
Unable to open the device driver. Action: Use MAP0210 General problem resolution. |
| 682-121 | 682 | The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution. |
| 682-122 | 682 | The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution. |
| 682-123 | 682 | The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution. |
| 682-125 | 682
B88 |
The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution. |
| 682-126 | 682 | The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution. |
| 682-127 | 682 | The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution. |
| 682-128 | 682 | The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution |
| 682-129 | 682 | The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution. |
| 682-150 | 682
Test Disc |
A media error was detected. Action: Use MAP0210 General problem resolution. |
| 682-151 | 682
B88 |
A command timeout was detected. Action: Use MAP0210 General problem resolution. |
| 682-152 | 682 | A command reservation conflict was detected. Action: Use MAP0210 General problem resolution. |
| 682-162 | 682 | The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution. |
| 682-171 | 682 | Unable to reserve device. Action: Use MAP0210 General problem resolution. |
| 682-172 | 682 | Unable to do configuration. Action: Use MAP0210 General problem resolution. |
| 682-173 | 682 | Unable to open device driver. Action: Use MAP0210 General problem resolution. |
| 682-175 | 682 | The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution. |
| 682-198 | 682
B88 |
Undefined error detected. Action: Use MAP0210 General problem resolution. |
| 682-199 | 682 | Undefined error detected. Action: Use MAP0210 General problem resolution. |
| 682-211 | 682 | The LED test failed. Action: Use MAP0210 General problem resolution. |
| 682-281 | 682 | No tone during audio test. Action: Use MAP0210 General problem resolution. |
| 682-301 | 682 | Errors found during ELA. Action: Use MAP0210 General problem resolution. |
| 682-302 | 682
B88 |
Errors found during ELA. Action: Use MAP0210 General problem resolution. |
| 683-128 | 683 | Error Log Analysis Indicates hardware failure VSS2105 Model B09. Action: Use MAP0210 General problem resolution. |
| 686-114 | 686 | The register verification test failed. Action: Use MAP0210 General problem resolution. |
| 686-124 | 686 | The adapter RAM verification test failed. Action: Use MAP0210 General problem resolution. |
| 686-152 | 686
D57 |
The data wrap communication test failed. Action: Use MAP0210 General problem resolution. |
| 686-153 | 686 | The modem control line test failed. Action: Use MAP0210 General problem resolution. |
| 686-252 | 686 | The data wrap communication test failed. Action: Use MAP0210 General problem resolution. |
| 686-253 | 686 | The modem control line test failed. Action: Use MAP0210 General problem resolution. |
| 686-501 | 686 | Adapter Reset failed Action: Use MAP0210 General problem resolution. |
| 686-511 | 686 | Adapter to host memory test failed (byte tag test). Action: Use MAP0210 General problem resolution. |
| 686-512 | 686 | Adapter to host memory test failed (word tag test). Action: Use MAP0210 General problem resolution. |
| 686-513 | 686 | Adapter to host memory test failed (byte pattern test). Action: Use MAP0210 General problem resolution. |
| 686-514 | 686 | Adapter to host memory test failed (word pattern test). Action: Use MAP0210 General problem resolution. |
| 686-521 | 686 | Adapter BIOS POST CPU failed. Action: Use MAP0210 General problem resolution. |
| 686-522 | 686 | Adapter BIOS POST Checksum failed. Action: Use MAP0210 General problem resolution. |
| 686-523 | 686 | Adapter BIOS POST Timer failed. Action: Use MAP0210 General problem resolution. |
| 686-524 | 686 | Adapter BIOS POST RAM failed. Action: Use MAP0210 General problem resolution. |
| 686-526 | 686 | Adapter BIOS POST Async Ports failed. Action: Use MAP0210 General problem resolution. |
| 686-527 | 686 | Adapter BIOS test failed. Action: Use MAP0210 General problem resolution. |
| 686-528 | 686 | Adapter BIOS Reset failed. Action: Use MAP0210 General problem resolution. |
| 686-529 | 686 | Adapter BIOS Download failed. Action: Use MAP0210 General problem resolution. |
| 686-531 | 686 | Adapter BIOS Command failed. Action: Use MAP0210 General problem resolution. |
| 686-533 | 686 | Adapter BIOS Timer test failed. Action: Use MAP0210 General problem resolution. |
| 686-534 | 686 | Adapter BIOS RAM test failed. Action: Use MAP0210 General problem resolution. |
| 686-541 | 686 | Port async internal loopback test failed (general). Action: Use MAP0210 General problem resolution. |
| 686-542 | 686 | Port async internal loopback test failed (no response from the port). Action: Use MAP0210 General problem resolution. |
| 686-551 | 686 | Port async external loopback test failed (general). Action: Use MAP0210 General problem resolution. |
| 686-552 | 686 | Port async external loopback test failed (data signals). Action: Use MAP0210 General problem resolution. |
| 686-553 | 686 | Port async external loopback test failed (control signals). Action: Use MAP0210 General problem resolution. |
| 686-554 | 686 | Port async external loopback test failed (modem signals). Action: Use MAP0210 General problem resolution. |
| 686-555 | 686 | Port async external loopback test failed (no response from port). Action: Use MAP0210 General problem resolution. |
| 686-901 to 686-920 | software
686 |
An unexpected error occurred that can be attributed to software or hardware. Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use MAP 210 with a FFC of 686; otherwise, suspect a software problem. |
| 686-921 | software
686 |
The adapter failed to configure. Action: Use MAP0210 General problem resolution. |
| 686-922 to 686-924 | software
686 |
An unexpected error occurred that can be attributed to software or hardware. Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use MAP0210 General problem resolution with a FFC of 686; otherwise, suspect a software problem. |
| 686-925 | 686 | The adapter failed to configure software Action: Use MAP0210 General problem resolution. |
| 686-926 to 686-950 | software
686 |
An unexpected error occurred that can be attributed to software or hardware. Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network-based diagnostics, use MAP0210 General problem resolution with a FFC of 686; otherwise, suspect a software problem. |
| 687-111 | 687 | The controller register test failed. Action: Use MAP0210 General problem resolution. |
| 687-114 | 687 | The register verification test failed. Action: Use MAP0210 General problem resolution. |
| 687-124 | 687 | The adapter RAM verification test failed. Action: Use MAP0210 General problem resolution. |
| 687-144 | 687 | The sync line test failed. Action: Use MAP0210 General problem resolution. |
| 687-152 | 837
684 687 152 |
The data wrap communication test failed. Action: Use MAP0210 General problem resolution. |
| 687-153 | 687 | The modem control line test failed. Action: Use MAP0210 General problem resolution. |
| 687-244 | 687 | The sync line test failed. Action: Use MAP0210 General problem resolution. |
| 687-252 | 687 | The data wrap communication test failed. Action: Use MAP0210 General problem resolution. |
| 687-253 | 687 | The modem control line test failed. Action: Use MAP0210 General problem resolution. |
| 687-501 | 687 | Adapter Reset failed. Action: Use MAP0210 General problem resolution. |
| 687-502 | 687 | Adapter Fuse failed. Action: Use MAP0210 General problem resolution. |
| 687-511 | 687 | Adapter to host memory test failed (byte tag test). Action: Use MAP0210 General problem resolution. |
| 687-512 | 687 | Adapter to host memory test failed (word tag test). Action: Use MAP0210 General problem resolution. |
| 687-513 | 687 | Adapter to host memory test failed (byte pattern test). Action: Use MAP0210 General problem resolution. |
| 687-514 | 687 | Adapter to host memory test failed (word pattern test). Action: Use MAP0210 General problem resolution. |
| 687-521 | 687 | Adapter BIOS POST CPU failed. Action: Use MAP0210 General problem resolution. |
| 687-522 | 687 | Adapter BIOS POST Checksum failed. Action: Use MAP0210 General problem resolution. |
| 687-523 | 687 | Adapter BIOS POST Timer failed. Action: Use MAP0210 General problem resolution. |
| 687-524 | 687 | Adapter BIOS POST RAM failed. Action: Use MAP0210 General problem resolution. |
| 687-525 | 687 | Adapter BIOS POST Sync Line failed. Action: Use MAP0210 General problem resolution. |
| 687-527 | 687 | Adapter BIOS test failed. Action: Use MAP0210 General problem resolution. |
| 687-528 | 687 | Adapter BIOS Reset failed. Action: Use MAP0210 General problem resolution. |
| 687-529 | 687 | Adapter BIOS Download failed. Action: Use MAP0210 General problem resolution. |
| 687-531 | 687 | Adapter BIOS Command failed. Action: Use MAP0210 General problem resolution. |
| 687-533 | 687 | Adapter BIOS Timer test failed. Action: Use MAP0210 General problem resolution. |
| 687-534 | 687 | Adapter BIOS RAM test failed. Action: Use MAP0210 General problem resolution. |
| 687-541 | 687 | Port sync internal loopback test failed. Action: Use MAP0210 General problem resolution. |
| 687-551 | 687 | Port sync external loopback test failed. Action: Use MAP0210 General problem resolution. |
| 687-600 | 687 | 232RAN status test failed. Action: Use MAP0210 General problem resolution. |
| 687-700 | 687 | 422RAN status test failed. Action: Use MAP0210 General problem resolution. |
| 687-901 to 687-920 | software
687 |
An unexpected error occurred that can be attributed to software or hardware. Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network-based diagnostics, use MAP0210 General problem resolution with a FFC of 687; otherwise, suspect a software problem. |
| 687-921 | software
687 |
The adapter failed to configure. Action: Use MAP0210 General problem resolution. |
| 687-922 to 687-924 | software
687 |
An unexpected error occurred that can be attributed to software or hardware. Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network-based diagnostics, use MAP0210 General problem resolution. with a FFC of 687; otherwise, suspect a software problem. |
| 687-925 | software
687 |
The adapter failed to configure. Action: Use MAP0210 General problem resolution. |
| 687-926 to 687-950 | software
687 |
An unexpected error occurred that can be attributed to software or hardware. Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use MAP0210 General problem resolution with a FFC of 687; otherwise, suspect a software problem. |
| 689-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 68C-101 | 68C | Timeout while attempting to communicate with SCSI device. Action: Use MAP0210 General problem resolution. |
| 68C-102 | 68C | The SCSI device indicates busy. Action: Use MAP0210 General problem resolution. |
| 68C-103 | 68C | The SCSI device indicates a reservation conflict. Action: Use MAP0210 General problem resolution. |
| 68C-104 | 68C | The SCSI device indicates a check condition. Action: Use MAP0210 General problem resolution. |
| 68C-105 | 68C | An error is detected in request sense data. Action: Use MAP0210 General problem resolution. |
| 68C-107 | 68C | Sense data from the SCSI drive has unexpected data. Action: Use MAP0210 General problem resolution. |
| 68C-110 | 68C | The Reserve command failed. Action: Use MAP0210 General problem resolution. |
| 68C-111 | 68C | Invalid condition from the drive after a reserve. Action: Use MAP0210 General problem resolution. |
| 68C-112 | 68C | The write-protect sensor test failed. Action: Use MAP0210 General problem resolution. |
| 68C-113 | 68C | Invalid condition from drive after a request sense. Action: Use MAP0210 General problem resolution. |
| 68C-114 | 68C | Timeout while attempting to communicate with the SCSI device. Action: Use MAP0210 General problem resolution. |
| 68C-120 | 68C | The Inquiry command failed. Action: Use MAP0210 General problem resolution. |
| 68C-130 | 68C
media |
The Load command failed. Action: Use MAP0210 General problem resolution. |
| 68C-134 | B88
software |
The adapter failed to configure. Action: Use MAP0210 General problem resolution. |
| 68C-135 | 68C
media |
The Unload command failed. Action: Use MAP0210 General problem resolution. |
| 68C-140 | 68C | The Mode Select command failed. Action: Use MAP0210 General problem resolution. |
| 68C-150 | 68C
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution. |
| 68C-160 | 68C
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution. |
| 68C-161 | 68C
B88 |
Invalid condition from the drive after a reserve. Action: Use MAP0210 General problem resolution. |
| 68C-163 | 68C
B88 |
Invalid condition from the drive after a request sense. Action: Use MAP0210 General problem resolution. |
| 68C-164 | 68C
B88 |
Timeout while attempting to communicate with the SCSI device. Action: Use MAP0210 General problem resolution. |
| 68C-165 | 68C
B88 276 |
Write, Read and Compare Test failed. Action: Use MAP0210 General problem resolution. |
| 68C-166 | 68C
B88 software |
Unable to configure the device. Action: Use MAP0210 General problem resolution. |
| 68C-167 | 68C
B88 |
An unexpected SCSI error occurred. Action: Use MAP0210 General problem resolution. |
| 68C-168 | B88
software |
The adapter failed to configure. Action: Use MAP0210 General problem resolution. |
| 68C-169 | 68C
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution. |
| 68C-170 | 68C
B88 media |
The Read, Write and Compare test failed. Action: Use MAP0210 General problem resolution. |
| 68C-180 | 68C
media |
The Load command failed. Action: Use MAP0210 General problem resolution. |
| 68C-185 | 68C
media |
The Unload command failed. Action: Use MAP0210 General problem resolution. |
| 68C-190 | 68C | The Mode Select command failed. Action: Use MAP0210 General problem resolution. |
| 68C-200 | 68C
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution. |
| 68C-201 | 68C
B88 |
Error diagnosed from error log analysis. Action: Use MAP0210 General problem resolution. |
| 68C-210 | 68C
B88 |
The device configuration failed. Action: Use MAP0210 General problem resolution. |
| 68C-211 | 68C
B88 |
The device open failed. Action: Use MAP0210 General problem resolution. |
| 68C-220 | 68C | The Release command failed. Action: Use MAP0210 General problem resolution. |
| 68C-230 | 68C | The Request Sense command failed. Action: Use MAP0210 General problem resolution. |
| 68C-240 | 68C | The Openx command failed. Action: Use MAP0210 General problem resolution. |
| 68C-260 | 68C | The device configuration failed. Action: Use MAP0210 General problem resolution. |
| 68C-261 | 68C | The device open failed. Action: Use MAP0210 General problem resolution. |
| 68C-300 | 68C
software |
The device configuration failed. Action: Use MAP0210 General problem resolution. |
| 68C-310 | B88
68C software |
SCSI adapter configuration failed. Action: Use MAP0210 General problem resolution. |
| 68C-320 | 68C
media |
Error log analysis indicates a failure. Action: Use MAP0210 General problem resolution. |
| 68C-411 to 68C-423 | B88
68C software |
A reservation conflict occurred. Action: Use MAP0210 General problem resolution. |
| 68C-511 to 68C-523 | B88
68C |
The drive returned bad or non-extended sense data. Action: Use MAP0210 General problem resolution. |
| 68C-611 to 68C-623 | B88
68C software |
An adapter or bus I/O error occurred. Action: Use MAP0210 General problem resolution. |
| 68C-711 to 68C-723 | B88
68C software |
A device timeout error occurred. Action: Use MAP0210 General problem resolution. |
| 68E-001 | Software
68E |
Software error. Action: Use MAP0210 General problem resolution. |
| 68E-002 | Software
68E |
Adapter failure. Action: Use MAP0210 General problem resolution. |
| 68E-003 | 68E
227 |
Adapter failure. Action: Use MAP0210 General problem resolution. |
| 68E-004 | 68E
Monitor/Cable |
Display failure. Action: Use MAP0210 General problem resolution. |
| 68E-005 | 68E
227 Monitor/Cable |
Adapter failure. Action: Use MAP0210 General problem resolution. |
| 690-xxx | 691
227 |
See SCSI Devices SRNs (ssss-102 to ssss-640). |
| 692-110 | 692 | The Reserve command failed. Action: Use MAP0210 General problem resolution. |
| 692-120 | 692 | The Inquiry command failed. Action: Use MAP0210 General problem resolution. |
| 692-130 | 692
media |
The Load command failed. Action: Use MAP0210 General problem resolution. |
| 692-135 | 692
media |
The Unload command failed. Action: Use MAP0210 General problem resolution. |
| 692-140 | 692 | The Mode Select command failed. Action: Use MAP0210 General problem resolution. |
| 692-150 | 692
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution. |
| 692-160 | 692
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution. |
| 692-169 | 692
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution. |
| 692-170 | 692
B88 media |
The Read, Write and Compare test failed. Action: Use MAP0210 General problem resolution. |
| 692-180 | 692
media |
The Load command failed. Action: Use MAP0210 General problem resolution. |
| 692-185 | 692
media |
The Unload command failed. Action: Use MAP0210 General problem resolution. |
| 692-190 | 692 | The Mode Select command failed. Action: Use MAP0210 General problem resolution. |
| 692-200 | 692
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution. |
| 692-210 | 692
B88 |
The device configuration failed. Action: Use MAP0210 General problem resolution. |
| 692-220 | 692 | The Release command failed. Action: Use MAP0210 General problem resolution. |
| 692-230 | 692 | The Request Sense command failed. Action: Use MAP0210 General problem resolution. |
| 692-240 | 692 | The Openx command failed. Action: Use MAP0210 General problem resolution. |
| 692-300 | 692
software |
The device configuration failed. Action: Use MAP0210 General problem resolution. |
| 692-310 | B88
692 software |
SCSI adapter configuration failed. Action: Use MAP0210 General problem resolution. |
| 692-320 | 692
media |
Error log analysis indicates a failure. Action: Use MAP0210 General problem resolution. |
| 692-411 to 692-423 | B88
692 software |
A reservation conflict occurred. Action: Use MAP0210 General problem resolution. |
| 692-511 to 692-523 | B88
692 |
The drive returned bad or non-extended sense data. Action: Use MAP0210 General problem resolution. |
| 692-611 to 692-623 | B88
692 software |
An adapter or bus I/O error occurred. Action: Use MAP0210 General problem resolution. |
| 692-711 to 692-723 | B88
692 software |
A device timeout error occurred. Action: Use MAP0210 General problem resolution. |
| 697-103 | 697
software 227 |
Charm software reset failure. Action: Use MAP0210 General problem resolution. |
| 697-104 | 697
software 227 |
Packet memory error. Action: Use MAP0210 General problem resolution. |
| 697-105 | 697
software 227 |
Control memory failure. Action: Use MAP0210 General problem resolution. |
| 697-106 | 697 | Link-R detected bad parity. Action: Use MAP0210 General problem resolution. |
| 697-107 | 697 | Suni detected bad parity. Action: Use MAP0210 General problem resolution. |
| 697-108 | 697 | Suni initialization failure. Action: Use MAP0210 General problem resolution. |
| 697-109 | Wrap Plug
697 |
Loss of light detected in Link test. Action: Check wrap plug installation. Action: Use MAP0210 General problem resolution. |
| 697-10B | Wrap Plug
697 |
External Loopback failed Action: Check wrap plug installation. Action: Use MAP0210 General problem resolution. |
| 697-10C | 697
software 227 |
Internal Loopback failed. Action: Use MAP0210 General problem resolution. |
| 697-10D | 697
software 227 |
DMS failed. Action: Use MAP0210 General problem resolution. |
| 697-121 | 697 | Adapter memory test failure. Action: Use MAP0210 General problem resolution. |
| 697-122 | 697 | Adapter checksum failure. Action: Use MAP0210 General problem resolution. |
| 697-123 | 697 | Internal wrap test failure Action: Use MAP0210 General problem resolution. |
| 697-124 | 697 | External wrap test failure Action: Use MAP0210 General problem resolution. |
| 697-125 | 221 | Enhanced Error Handling failure on bus Action: Use MAP0210 General problem resolution. |
| 697-126 | 221 | Enhanced Error Handling failure on EADS chip Action: Use MAP0210 General problem resolution. |
| 697-127 | 697 | Enhanced Error Handling failure on adapter Action: Use MAP0210 General problem resolution. |
| 697-1FF | 697
software 227 |
EPROM checksum failed Action: Use MAP0210 General problem resolution. |
| 697-200 | 697
software 227 |
Klog error Action: Use MAP0210 General problem resolution. |
| 697-201 | 697
software 227 |
ASL error Action: Use MAP0210 General problem resolution. |
| 697-202 | 697
software 227 |
ODM Initialization error Action: Use MAP0210 General problem resolution. |
| 697-203 | 697
software 227 |
Diagnostic configuration failure. Action: Use MAP0210 General problem resolution. |
| 697-205 | 697
software 227 |
Error in diag open. Action: Use MAP0210 General problem resolution. |
| 697-206 | 697
221 |
Error in releasing adapter Action: Use MAP0210 General problem resolution. |
| 697-221 | 697
221 |
Hardware failure opening the adapter Action: Use MAP0210 General problem resolution. |
| 697-222 | 697
221 |
Enhanced Error Handling failure opening the adapter Action: Use MAP0210 General problem resolution. |
| 697-223 | 697
221 |
Interrupt test failure Action: Use MAP0210 General problem resolution. |
| 697-224 | 697
221 |
Adapter DMA test failure Action: Use MAP0210 General problem resolution. |
| 697-701 | 697
221 |
Error Log Analysis indicates an I/O failure on the adapter. Action: Use MAP0210 General problem resolution. |
| 697-702 | 697 | Error Log Analysis indicates an unrecovered interrupt error. Action: Use MAP0210 General problem resolution. |
| 698-100 | 697
software 227 |
Charm memory write failure. Action: Use MAP0210 General problem resolution. |
| 698-101 | 697
software 227 |
Charm memory read failure. Action: Use MAP0210 General problem resolution. |
| 698-102 | 697
software 227 |
PCI configuration register write failure. Action: Use MAP0210 General problem resolution. |
| 698-103 | 697
software 227 |
Charm software reset failure. Action: Use MAP0210 General problem resolution. |
| 698-104 | 697
software 227 |
Packet memory error Action: Use MAP0210 General problem resolution. |
| 698-105 | 697
software 227 |
Control memory failure. Action: Use MAP0210 General problem resolution. |
| 698-106 | 698 | Link-R detected bad parity. Action: Use MAP0210 General problem resolution. |
| 698-107 | 698 | Suni detected bad parity. Action: Use MAP0210 General problem resolution. |
| 698-108 | 698 | Suni initialization failure. Action: Use MAP0210 General problem resolution. |
| 698-109 | Wrap Plug
698 |
Loss of light detected in Link test. Action: Check wrap plug installation. Action: Use MAP0210 General problem resolution. |
| 698-10B | Wrap Plug
698 |
External Loopback failed Action: Check wrap plug installation. Action: Use MAP0210 General problem resolution. |
| 698-10C | 698
software 227 |
Internal Loopback failed. Action: Use MAP0210 General problem resolution. |
| 698-10D | 698
software 227 |
DMS failed. Action: Use MAP0210 General problem resolution. |
| 698-121 | 698 | Adapter memory test failure. Action: Use MAP0210 General problem resolution. |
| 698-122 | 698 | Adapter checksum failure. Action: Use MAP0210 General problem resolution. |
| 698-123 | 698 | Internal wrap test failure. Action: Use MAP0210 General problem resolution. |
| 698-124 | 698 | External wrap test failure. Action: Use MAP0210 General problem resolution. |
| 698-125 | 221 | Enhanced Error Handling failure on bus. Action: Use MAP0210 General problem resolution. |
| 698-126 | 221 | Enhanced Error Handling failure on EADS chip. Action: Use MAP0210 General problem resolution. |
| 698-127 | 698 | Enhanced Error Handling failure on adapter. Action: Use MAP0210 General problem resolution. |
| 698-1FF | 698
software 227 |
EPROM checksum failed. Action: Use MAP0210 General problem resolution. |
| 698-200 | 698
software 227 |
Klog error. Action: Use MAP0210 General problem resolution. |
| 698-201 | 698
software 227 |
ASL error. Action: Use MAP0210 General problem resolution. |
| 698-202 | 698
software 227 |
ODM Initialization error. Action: Use MAP0210 General problem resolution. |
| 698-203 | 698
software 227 |
Diagnostic configuration failure. Action: Use MAP0210 General problem resolution. |
| 698-205 | 698
software 227 |
Error in diag open. Action: Use MAP0210 General problem resolution. |
| 698-206 | 698
software 227 |
Error in releasing adapter. Action: Use MAP0210 General problem resolution. |
| 698-221 | 698
221 |
Hardware failure opening the adapter. Action: Use MAP0210 General problem resolution. |
| 698-222 | 698
221 |
Enhanced Error Handling failure opening the adapter. Action: Use MAP0210 General problem resolution. |
| 698-223 | 698
221 |
Interrupt test failure. Action: Use MAP0210 General problem resolution. |
| 698-224 | 698
221 |
Adapter DMA test failure. Action: Use MAP0210 General problem resolution. |
| 698-701 | 698
221 |
Error Log Analysis indicates an I/O failure on the adapter. Action: Use MAP0210 General problem resolution. |
| 698-702 | 698 | Error Log Analysis indicates an unrecovered interrupt error. Action: Use MAP0210 General problem resolution. |
| 69b-101 | 69b | EPROM test failure. Action: Use MAP0210 General problem resolution. |
| 69b-102 | 69b | Adapter SDRAM failure. Action: Use MAP0210 General problem resolution. |
| 69b-103 | 69b | Adapter checksum failure. Action: Use MAP0210 General problem resolution. |
| 69b-104 | 69b | Adapter memory test failure. Action: Use MAP0210 General problem resolution. |
| 69b-105 | 69b | Adapter buffer test failure. Action: Use MAP0210 General problem resolution. |
| 69b-106 | 69b | Adapter cache test failure. Action: Use MAP0210 General problem resolution. |
| 69b-107 | 69b | Internal loopback test failure. Action: Use MAP0210 General problem resolution. |
| 69b-108 | 69b | External wrap test failure. Action: Use MAP0210 General problem resolution. |
| 69b-109 | 221 | Enhanced Error Handling failure on bus. Action: Use MAP0210 General problem resolution. |
| 69b-110 | 221 | Enhanced Error Handling failure on Eads chip. Action: Use MAP0210 General problem resolution. |
| 69b-111 | 69b | Enhanced Error Handling failure on adapter.Action: Use MAP0210 General problem resolution. |
| 69b-201 | 69b
221 |
Hardware failure opening adapter. Action: Use MAP0210 General problem resolution. |
| 69b-202 | 69b
221 |
Interrupt test failure. Action: Use MAP0210 General problem resolution. |
| 69b-203 | 69b
221 |
Adapter DMA test failure. Action: Use MAP0210 General problem resolution. |
| 69b-204 | 69b
221 |
Enhanced error handling failure opening the adapter. Action: Use MAP0210 General problem resolution. |
| 69b-701 | 69b | Error Log Analysis indicates an I/O failure on the adapter. Action: Use MAP0210 General problem resolution. |
| 69d-101 | 69d | EPROM test failure. Action: Use MAP0210 General problem resolution. |
| 69d-102 | 69d | Adapter SDRAM failure. Action: Use MAP0210 General problem resolution. |
| 69d-103 | 69d | Adapter checksum failure. Action: Use MAP0210 General problem resolution. |
| 69d-104 | 69d | Adapter memory test failure. Action: Use MAP0210 General problem resolution. |
| 69d-105 | 69d | Adapter buffer test failure. Action: Use MAP0210 General problem resolution. |
| 69d-106 | 69d | Adapter cache test failure. Action: Use MAP0210 General problem resolution. |
| 69d-107 | 69d | Internal loopback test failure. Action: Use MAP0210 General problem resolution. |
| 69d-108 | 69d | External wrap test failure. Action: Use MAP0210 General problem resolution. |
| 69d-109 | 221 | Enhanced Error Handling failure on bus. Action: Use MAP0210 General problem resolution. |
| 69d-110 | 221 | Enhanced Error Handling failure on Eads chip. Action: Use MAP0210 General problem resolution. |
| 69d-111 | 69d | Enhanced Error Handling failure on adapter. Action: Use MAP0210 General problem resolution. |
| 69d-201 | 69d
221 |
Hardware failure opening adapter. Action: Use MAP0210 General problem resolution. |
| 69d-202 | 69d
221 |
Interrupt test failure. Action: Use MAP0210 General problem resolution. |
| 69d-203 | 69d
221 |
Adapter DMA test failure. Action: Use MAP0210 General problem resolution. |
| 69d-204 | 69d
221 |
Enhanced error handling failure opening the adapter. Action: Use MAP0210 General problem resolution. |
| 69d-701 | 69d | Error Log Analysis indicates an I/O failure on the adapter. Action: Use MAP0210 General problem resolution. |