SRNs 60B-xxx through 6C9-600

This section lists the SRNs 60B-xxx through 6C9-600.

Replace FRU parts in the order by which the "Failing Function Codes" are listed. Go to Failing function code list to access the failing function codes.
Note: Some SRNs in might have 4 rather than 3 digits after the dash (-).
Service Request Number Failing Function Codes Description/Action
601-xxx   See SCSI Devices SRNs (ssss-102 to ssss-640).
60B-xxx   See SCSI Devices SRNs (ssss-102 to ssss-640).
613-xxx 613 An 8-mm 80-GB VXA-2 tape device problem has occurred. Action: Use MAP0210 General problem resolution.
61B-xxx   See SCSI Devices SRNs (ssss-102 to ssss-640).
61D-xxx   See SCSI Devices SRNs (ssss-102 to ssss-640).
61E-xxx   See SCSI Devices SRNs (ssss-102 to ssss-640).
621-xxx   See SCSI Devices SRNs (ssss-102 to ssss-640).
623-xxx   See SCSI Devices SRNs (ssss-102 to ssss-640).
624-xxx   See SCSI Devices SRNs (ssss-102 to ssss-640).
62D-xxx   See SCSI Devices SRNs (ssss-102 to ssss-640).
62E-xxx   See SCSI Devices SRNs (ssss-102 to ssss-640).
636-101 636 EPROM test failure.

Action: Use MAP0210 General problem resolution.

636-102 636 Adapter SDRAM failure.

Action: Use MAP0210 General problem resolution.

636-103 636 Adapter checksum failure.

Action: Use MAP0210 General problem resolution.

636-104 636 Adapter memory test failure.

Action: Use MAP0210 General problem resolution.

636-105 636 Adapter buffer test failure.

Action: Use MAP0210 General problem resolution.

636-106 636 Adapter cache test failure.

Action: Use MAP0210 General problem resolution.

636-107 636 Internal loop-back test failure.

Action: Use MAP0210 General problem resolution.

636-108 636 External wrap test failure.

Action: Use MAP0210 General problem resolution.

636-109 221 Enhanced error handling failure on the bus.

Action: Use MAP0210 General problem resolution.

636-110 221 Enhanced error handling failure on the Eads chip.

Action: Use MAP0210 General problem resolution.

636-111 636 Enhanced error handling failure on the adapter.

Action: Use MAP0210 General problem resolution.

636-201
636
221
Hardware failure opening adapter.

Action: Use MAP0210 General problem resolution.

636-202
636
221
Interrupt test failure.

Action: Use MAP0210 General problem resolution.

636-203
636
221
Adapter DMA test failure.

Action: Use MAP0210 General problem resolution.

636-204
636
221
Enhanced error handling failure opening the adapter.

Action: Use MAP0210 General problem resolution.

636-701 636 ELA indicates an I/O failure on the adapter.

Action: Use MAP0210 General problem resolution.

638-xxx   See SCSI Devices SRNs (ssss-102 to ssss-640).
639-xxx   See SCSI Devices SRNs (ssss-102 to ssss-640).
63A-xxx to 63F-xxx   See SCSI Devices SRNs (ssss-102 to ssss-640).
640-xxx   See SCSI Devices SRNs (ssss-102 to ssss-640).
643-xxx   See SCSI Devices SRNs (ssss-102 to ssss-640).
644-xxx   See SCSI Devices SRNs (ssss-102 to ssss-640).
646-101 D46 External Test Failure.

Action: Use MAP0210 General problem resolution.

646-102 240 External Test Failure.

Action: Use MAP0210 General problem resolution.

646-103 646 I/O Test Failure.

Action: Use MAP0210 General problem resolution.

646-104
646
221
Adapter On-card Test Failure.

Action: Use MAP0210 General problem resolution.

646-105 646 Wrap Test Failure.

Action: Use MAP0210 General problem resolution.

646-106 646 Enhanced Error Handling failure on bus.

Action: Use MAP0210 General problem resolution.

646-107 646 EEH failure on PCI-PCI bridge chip.

Action: Use MAP0210 General problem resolution.

646-108 646 Enhanced Error Handling failure on adapter.

Action: Use MAP0210 General problem resolution.

646-201
646
221
Configuration Register Test Failure.

Action: Use MAP0210 General problem resolution.

646-202
646
221
Wrap Test Failure.

Action: Use MAP0210 General problem resolution.

646-204
D46
240
External Test Failure.

Action: Use MAP0210 General problem resolution.

646-205
D46
646
External Test Failure.

Action: Run advanced diagnostics with wrap test for this resource to obtain a correct problem resolution.

646-206
240
646
External Test Failure.

Action: Run advanced diagnostics with wrap test for this resource to obtain a correct problem resolution.

646-302
240
D46
221
External Test Failure.

Action: Run advanced diagnostics with wrap test for this resource to obtain a correct problem resolution.

646-303
646
D46
221
External Test Failure.

Action: Run advanced diagnostics with wrap test for this resource to obtain a correct problem resolution.

646-401
240
646
D46
221
External Test Failure.

Action: Run advanced diagnostics with wrap test for this resource to obtain a correct problem resolution.

Action: Use MAP0210 General problem resolution.

646-701 646 Error log analysis indicates that an adapter error has occurred.

Action: Use MAP0210 General problem resolution.

646-702 646 Error log analysis indicates that an adapter check has occurred.

Action: Use MAP0210 General problem resolution.

646-703
646
221
Error log analysis indicates that a DMA failure has occurred.

Action: Use MAP0210 General problem resolution.

646-704
646
221
Error log analysis indicates that a PCI Bus error has occurred.

Action: Use MAP0210 General problem resolution.

646-705
646
221
Error log analysis indicates that a Programmed I/O error has occurred.

Action: Use MAP0210 General problem resolution.

646-706 646 ELA indicates a command write failure occurred.

Action: Use MAP0210 General problem resolution.

646-707 646 ELA indicates an internal adapter error has occurred.

Action: Use MAP0210 General problem resolution.

64A-xxx to 64F-xxx   See SCSI Devices SRNs (ssss-102 to ssss-640).
650-xxx 650 Disk drive configuration failed.

Action: Use MAP0210 General problem resolution.

653-xxx   See SCSI Devices SRNs (ssss-102 to ssss-640).
657-001
software
657
Software error.

Action: Use MAP0210 General problem resolution.

657-002
software
655
Adapter failure.

Action: Use MAP0210 General problem resolution.

657-003
657
227
Adapter failure.

Action: Use MAP0210 General problem resolution.

657-004
657
Monitor/Cable
Display failure.

Action: Use MAP0210 General problem resolution.

657-005
657
227
Monitor/Cable
Adapter failure.

Action: Use MAP0210 General problem resolution.

65A-xxx to 65F-xxx   See SCSI Devices SRNs (ssss-102 to ssss-640).
662-101 221 Enhanced error handling failure on the bus.

Action: Use MAP0210 General problem resolution.

662-102 293 Enhanced error handling failure on a PCI-PCI Bridge.

Action: Use MAP0210 General problem resolution.

662-103
662
221
Enhanced error handling failure on the adapter.

Action: Use MAP0210 General problem resolution.

662-212 662 FIFO empty bit set.

Action: Use MAP0210 General problem resolution.

662-213 662 FIFO empty bit clear.

Action: Use MAP0210 General problem resolution.

662-214 662 FIFO full bit set.

Action: Use MAP0210 General problem resolution.

662-215 662 FIFO full bit clear.

Action: Use MAP0210 General problem resolution.

662-216 662 FIFO data miscompare.

Action: Use MAP0210 General problem resolution.

662-217 662 SCSI FIFO data miscompare.

Action: Use MAP0210 General problem resolution.

662-218 662 SCSI FIFO underflow.

Action: Use MAP0210 General problem resolution.

662-219   SCSI parity error.

Action: Go to MAP0050 SCSI bus problems.

662-220 662 SCSI FIFO flags error.

Action: Use MAP0210 General problem resolution.

662-221
662
221
Miscompare during the write/read of the configuration register.

Action: Use MAP0210 General problem resolution.

662-222 662 Error during the write/read of the memory register.

Action: Use MAP0210 General problem resolution.

662-223 662 Miscompare during the write/read of the memory I/O register.

Action: Go to MAP0050 SCSI bus problems.

662-224
662
221
SCSI configuration register read or write error.

Action: Use MAP0210 General problem resolution.

662-225 662 Adapter POST failed.

Action: Use MAP0210 General problem resolution.

662-226   SCSI wrap or PTC failure.

Action: Go to MAP0050 SCSI bus problems.

662-227
662
221
SCSI adapter test failure.

Action: Use MAP0210 General problem resolution.

662-230   Arbitration test failed.

Action: Go to MAP0050 SCSI bus problems.

662-231   Function could not complete.

Action: Go to MAP0050 SCSI bus problems.

662-232   SCSI bus data miscompare.

Action: Go to MAP0050 SCSI bus problems.

662-240   No terminal power.

Action: Go to MAP0050 SCSI bus problems.

662-242   SCSI bus problem.

Action: Go to MAP0050 SCSI bus problems.

662-301
662
221
The parent device open failed.

Action: Use MAP0210 General problem resolution.

662-701 662 Error log analysis indicates a PCI SCSI adapter failure.

Action: Use MAP0210 General problem resolution.

662-801   Error log analysis indicates a terminator problem.

Action: Run the diagnostics on the adapter in system verification mode. If an SRN is reported, use the SRN to resolve the problem. If an SRN is not reported, use the SCSI service hints in General SCSI Configuration Checks to resolve the problem.

662-802   Error log analysis indicates that multiple attempts to reset the SCSI bus have timed out.

Action: Run the diagnostics on the adapter in system verification mode. If an SRN is reported, use the SRN to resolve the problem. If an SRN is not reported, use the SCSI service hints in General SCSI Configuration Checks to resolve the problem.

662-803   Error log analysis indicates that multiple SCSI bus errors have occurred.

Action: Run the diagnostics on the adapter in system verification mode. If an SRN is reported, use the SRN to resolve the problem. If an SRN is not reported, use the SCSI service hints in General SCSI Configuration Checks to resolve the problem.

663-101
663
C94
C95
IBM ARTIC960RxD or RxF PCI Adapter Central Processing Unit test failure.

Action: Use MAP0210 General problem resolution.

663-102
663
C94
C95
IBM ARTIC960RxD or RxF PCI Adapter Timer test failure.

Action: Use MAP0210 General problem resolution.

663-103
663
C94
C95
IBM ARTIC960RxD or RxF PCI Adapter Bus Interface test failure.

Action: Use MAP0210 General problem resolution.

663-104
663
C94
C95
IBM ARTIC960RxD or RxF PCI Adapter Dynamic Random Access Memory test failure.

Action: Use MAP0210 General problem resolution.

663-105
663
C94
C95
IBM ARTIC960RxD or RxF PCI Adapter Memory Protection test failure.

Action: Use MAP0210 General problem resolution.

663-106
663
C94
C95
IBM ARTIC960RxD PCI Adapter Debug Port test failure.

Action: Use MAP0210 General problem resolution.

663-107
C95
663
C97
Interface board wrap test failure.

Action: Use MAP0210 General problem resolution.

663-110
C94
663
C95
IBM ARTIC960RxD or RxF PCI Adapter Download Diagnostics test failure.

Action: Use MAP0210 General problem resolution.

663-123
C95
663
C97
Interface board non-wrap test failure.

Action: Use MAP0210 General problem resolution.

663-150
663
software
227
Device configuration failure.

Action: Use MAP0210 General problem resolution.

663-151
663
software
227
Device driver indicates a hardware failure.

Action: Use MAP0210 General problem resolution.

663-152 663 Failure and error in determining which type of IBM ARTIC960RxD PCI Adapter.

Action: Use MAP0210 General problem resolution.

663-153
663
227
C94
software
Error log analysis indicates an IBM ARTIC960RxD or RxF PCI Adapter failure.

Action: Use the errpt command to check error log.

Action: Use MAP0210 General problem resolution.

663-154
C94
663
C95
IBM ARTIC960RxD or RxF PCI Adapter initialization failure.

Action: Use MAP0210 General problem resolution.

663-155
C94
663
C95
IBM ARTIC960RxD or RxF PCI Adapter initialization failure.

Action: Use MAP0210 General problem resolution.

663-156
C94
663
C95
IBM ARTIC960RxD or RxF PCI Adapter initialization failure.

Action: Use MAP0210 General problem resolution.

663-157
C98
C97
C95
Cable wrap test failure.

Action: Use MAP0210 General problem resolution.

669-101 221 Enhanced error handling failure on bus.

Action: Use MAP0210 General problem resolution.

669-102 221 Enhanced error handling failure on Eads chip.

Action: Use MAP0210 General problem resolution.

669-103 669 Enhanced error handling failure on adapter.

Action: Use MAP0210 General problem resolution.

669-201
669
221
Configuration register test failure.

Action: Before going to MAP 210, look at the label on the adapter. If the label is A-A, use SRN 66C-201 instead, and go to MAP0210 General problem resolution.

669-202 669 I/O register test failure.

Action: Use MAP0210 General problem resolution.

669-203 669 Adapter memory test failure.

Action: Use MAP0210 General problem resolution.

669-204 669 Adapter initialization test failure.

Action: Use MAP0210 General problem resolution.

669-205 669 Internal loopback test failure.

Action: Use MAP0210 General problem resolution.

669-206 669 External wrap test failure (1000 Mbps).

Action: Use MAP0210 General problem resolution.

669-701 669 Error Log Analysis indicates that this device failed to initialize because it is not the IBM version of this adapter. AIX operating system cannot configure this non-IBM version of the adapter.

Action: Use MAP0210 General problem resolution.

669-702 669 Error Log Analysis indicates that this device failed to initialize due to a problem with the EEPROM on the adapter.

Action: Use MAP0210 General problem resolution.

669-703   Error Log Analysis indicates that this device has failed to initialize due to a self-test failure.

Action: Use MAP0210 General problem resolution.

669-704   Error Log Analysis indicates that this device has failed to initialize due to firmware download error.

Action: Use MAP0210 General problem resolution.

66A-101   Diagnostics indicates adapter configuration failure.

Action: Use MAP0210 General problem resolution.

66C-101 221 Enhanced error handling failure on bus.

Action: Use MAP0210 General problem resolution.

66C-102 221 Enhanced error handling failure on Eads chip.

Action: Use MAP0210 General problem resolution.

66C-103 66C Enhanced error handling failure on adapter.

Action: Use MAP0210 General problem resolution.

66C-201
66C
221
Configuration register test failure.

Action: Use MAP0210 General problem resolution.

66C-202 66C I/O register test failure.

Action: Use MAP0210 General problem resolution.

66C-203 66C Adapter memory test failure.

Action: Use MAP0210 General problem resolution.

66C-204 66C Adapter initialization test failure.

Action: Use MAP0210 General problem resolution.

66C-205 66C Internal loopback test failure.

Action: Use MAP0210 General problem resolution.

66C-206 66C External wrap test failure (1000 Mbps).

Action: Use MAP0210 General problem resolution.

66C-207 66C External wrap test failure (10 Mbps).

Action: Use MAP0210 General problem resolution.

66C-208 66C External wrap test failure (100 Mbps).

Action: Use MAP0210 General problem resolution.

66C-702 66C Error Log Analysis indicates that this device failed to initialize due to a problem with the EEPROM on the adapter.

Action: Use MAP0210 General problem resolution.

66C-703 66C Error Log Analysis indicates that this device has failed to initialize due to a self-test failure.

Action: Use MAP0210 General problem resolution.

66C-704 66C Error Log Analysis indicates that this device has failed to initialize due to firmware download error.

Action: Use MAP0210 General problem resolution.

66D-101
66D
227
The PCI wrap test failed.

Action: Use MAP0270 SCSI RAID problem resolution and verification.

66D-102
66D
E2A
The POST indicates an adapter failure.

Action: Use MAP0270 SCSI RAID problem resolution and verification.

66D-103 66D The POST indicates an adapter channel failure.

Action: Use MAP0270 SCSI RAID problem resolution and verification.

66D-104
190
B3A
The POST indicates a defective cable.

Action: Use MAP0210 General problem resolution.

66D-105 722 The POST indicates a defective backplane or external enclosure.

Action: Use MAP0210 General problem resolution.

66D-106 722 The POST indicates the last disk drive reconnected caused a channel failure.

Action: Use MAP0270 SCSI RAID problem resolution and verification.

66D-108 221 Enhanced error handling failure on bus.

Action: Use MAP0210 General problem resolution.

66D-109 66D The test indicates an adapter failure.

Action: Use MAP0270 SCSI RAID problem resolution and verification.

66D-110 722 The disk reported a Predictive Failure Analysis error (PFA).

Action: Use MAP0270 SCSI RAID problem resolution and verification.

66D-111 722 The disk drive has been failed by the adapter.

Action: Use MAP0270 SCSI RAID problem resolution and verification.

66D-112 722 ELA indicates that the disk reported a hard data error.

Action: Use MAP0270 SCSI RAID problem resolution and verification.

66D-113 722 ELA indicates that the disk reported a hard equipment error.

Action: Use MAP0270 SCSI RAID problem resolution and verification.

66D-114 E2A ELA indicates a cache failure.

Action: Use MAP0270 SCSI RAID problem resolution and verification.

66D-115 E3A ELA indicates that the cache battery is either low on power or has failed.

Action: Use MAP0270 SCSI RAID problem resolution and verification.

66D-116 66D Failed to disable data scrub.

Action: Use MAP0270 SCSI RAID problem resolution and verification.

66D-117 E2A POST indicates cache failure.

Action: Use MAP0270 SCSI RAID problem resolution and verification.

66D-118 E2A Adapter test indicates a cache failure.

Action: Use MAP0270 SCSI RAID problem resolution and verification.

66D-119 E2A Adapter test indicates that write cache is missing.

Action: Use MAP0270 SCSI RAID problem resolution and verification.

66D-120 E2A Adapter test indicates that cache size is invalid.

Action: Use MAP0270 SCSI RAID problem resolution and verification.

66D-121 E3A Adapter test indicates that the cache battery is low on power.

Action: Use MAP0270 SCSI RAID problem resolution and verification.

66D-122 66D Adapter test indicates cache battery failure.

Action: Use MAP0270 SCSI RAID problem resolution and verification.

66D-123 221 ELA indicates an adapter failure.

Action: Use MAP0270 SCSI RAID problem resolution and verification.

66D-124 221 Enhanced error handling failure on PCI-PCI Bridge.

Action: Use MAP0210 General problem resolution.

66D-125
66D
221
Enhanced error handling failure on adapter.

Action: Use MAP0210 General problem resolution.

66D-400
66D
190
B3A
722
The POST test indicates a channel failure.

Action: Use MAP0270 SCSI RAID problem resolution and verification.

66D-701
66D
221
Error Log Analysis indicates an enhanced error handling error.

Action: Use MAP0210 General problem resolution.

66E-100 66E Unable to configure the parent device.

Action: Use MAP0210 General problem resolution.

66E-102 66E SCSI command Inquiry has failed. Unable to get Additional Vital Product Data.

Action: Use MAP0210 General problem resolution.

66E-103 66E SCSI command Reserve has failed.

Action: Use MAP0210 General problem resolution.

66E-104 66E SCSI command Mode Sense has failed.

Action: Use MAP0210 General problem resolution.

66E-105 66E SCSI command Mode Select has failed.

Action: Use MAP0210 General problem resolution.

66E-106 66E SCSI command Allow Media Removal has failed.

Action: Use MAP0210 General problem resolution.

66E-107 66E SCSI command Prevent Media Removal has failed.

Action: Use MAP0210 General problem resolution.

66E-108 66E SCSI command Start Stop Unit has failed.

Action: Use MAP0210 General problem resolution.

66E-109 66E SCSI command Test Unit Ready has failed.

Action: Use MAP0210 General problem resolution.

66E-10A 66E SCSI command Send Diagnostic has failed.

Action: Use MAP0210 General problem resolution.

66E-10B 66E SCSI command Release has failed.

Action: Use MAP0210 General problem resolution.

66E-10F 66E Undetermined hardware error has occurred.

Action: Use MAP0210 General problem resolution.

66E-200
66E
B88
Unable to configure the device.

Action: Use MAP0210 General problem resolution.

66E-201
media
66E
DVD-RAM drive is unable to eject the tray.

Action: Verify that no external object prevents the drive from ejecting the tray. Verify that no media is stuck inside the drive. Otherwise, use MAP0210 General problem resolution.

66E-202
media
66E
DVD-RAM drive is unable to load the tray.

Action: Verify that no external object prevents the drive from ejecting the tray. Verify that no media is stuck inside the drive. Otherwise, use MAP0210 General problem resolution.

66E-203
media
66E
DVD-RAM drive is unable to detect the test medium.

Action: Verify that no external object prevents the drive from ejecting the tray. Verify that no media is stuck inside the drive. Otherwise, use MAP0210 General problem resolution.

66E-204
66E
B88
A SCSI reservation conflict has occurred.

Action: Use MAP0210 General problem resolution.

66E-205
media
66E
The Random Write/Read/Compare Test has detected a medium error while testing the DVD-RAM test medium.

Action: Run Diagnostic on this drive with another DVD-RAM test medium. Use MAP0210 General problem resolution.

66E-206
media
66E
The Random Write/Read/Compare Test has detected a hardware error while testing the DVD-RAM test medium.

Action: Run Diagnostic on this drive with another DVD-RAM test medium. Use MAP0210 General problem resolution.

66E-207
media
66E
The Random Read Test has detected a medium error while testing the CD-ROM test medium.

Action: Run Diagnostic on this drive with another DVD-RAM test medium. Use MAP0210 General problem resolution.

66E-208
media
66E
The Random Read Test has detected a hardware error while testing the CD-ROM test medium.

Action: Run Diagnostic on this drive with another DVD-RAM test medium. Use MAP0210 General problem resolution.

66E-209
media
66E
DVD-RAM drive is unable to determine the media type.
Action:
  1. Verify that the proper test medium is inserted.
  2. Clean the drive.
  3. Run Diagnostic on this drive with another test medium.
  4. Use MAP0210 General problem resolution.
66E-20A
media
66E
DVD-RAM drive has faulty write-protect-detection mechanism.
Action:
  1. Verify that the DVD-RAM test medium is not write-protected.
  2. Run Diagnostic on this drive with another DVD-RAM test medium.
  3. Use MAP0210 General problem resolution.
66E-20B
media
66E
DVD-RAM drive has detected a media error.
Action:
  1. Verify that the DVD-RAM test medium is inserted properly.
  2. Run Diagnostic on this drive with another DVD-RAM test medium.
  3. If the test fails with the new test media, use MAP0210 General problem resolution to replace the defective DVD-ROM drive.
66E-300
66E
B88
190
SCSI command timeout has occurred.

Action: Use MAP0210 General problem resolution to replace the defective DVD-ROM drive.

66E-301
66E
B88
190
Unit Attention has occurred.

Action: Use MAP0210 General problem resolution.

66E-700 66E ELA indicates an irrecoverable hardware error.

Action: Use MAP0210 General problem resolution.

66E-701 66E ELA indicates an undetermined hardware error.

Action: Use MAP0210 General problem resolution.

670-xxx to 673-xxx   See SCSI Devices SRNs (ssss-102 to ssss-640).
674-101
674
C94
C95
IBM ARTIC960Rx PCI Adapter Central Processing Unit (CPU) test failure.

Action: Use MAP0210 General problem resolution.

674-102
674
C94
C95
IBM ARTIC960Rx PCI Adapter Timer test failure.

Action: Use MAP0210 General problem resolution.

674-103
674
C94
C95
IBM ARTIC960Rx PCI Adapter Bus Interface test failure.

Action: Use MAP0210 General problem resolution.

674-104
674
C94
C95
IBM ARTIC960Rx PCI Adapter Dynamic Random Access Memory (DRAM) test failure.

Action: Use MAP0210 General problem resolution.

674-105
674
C94
C95
IBM ARTIC960Rx PCI Adapter Memory Protection test failure.

Action: Use MAP0210 General problem resolution.

674-106
674
C94
C95
IBM ARTIC960Rx PCI Adapter Debug Port test failure.

Action: Use MAP0210 General problem resolution.

674-107
674
C94
C95
Interface board wrap test failure.

Action: Use MAP0210 General problem resolution.

674-110
674
C94
C95
IBM ARTIC960Rx PCI Adapter Download Diagnostics test failure.

Action: Use MAP0210 General problem resolution.

674-123
C94
C95
Interface board non-wrap test failure.

Action: Use MAP0210 General problem resolution.

674-150
674
software
227
Device configuration failure.

Action: Use MAP0210 General problem resolution.

674-151
674
software
227
Device driver indicates a hardware failure.

Action: Use MAP0210 General problem resolution.

674-152 674 Failure and error in determining which type of IBM ARTIC960Rx PCI Adapter.

Action: Use MAP0210 General problem resolution.

674-153
674
software
C94
227
Error log analysis indicates an IBM ARTIC960Rx PCI Adapter failure. Action: Use the errpt command to check error log.

Action: Use MAP0210 General problem resolution.

674-154
C94
674
C95
IBM ARTIC960Rx PCI Adapter initialization failure. Action: Use MAP0210 General problem resolution.
674-155
C94
674
C95
IBM ARTIC960Rx PCI Adapter initialization failure. Action: Use MAP0210 General problem resolution.
674-156
C94
674
C95
IBM ARTIC960Rx PCI Adapter initialization failure. Action: Use MAP0210 General problem resolution.
674-157
C94
674
C95
Cable wrap test failure. Action: Use MAP0210 General problem resolution.
675-101
C94
674
C95
IBM ARTIC960Hx Adapter Central Processing Unit (CPU) test failure. Action: Use MAP0210 General problem resolution.
675-102
C94
674
C95
IBM ARTIC960Hx Adapter Timer test failure. Action: Use MAP0210 General problem resolution.
675-103
C94
674
C95
IBM ARTIC960Hx Adapter Bus Interface test failure. Action: Use MAP0210 General problem resolution.
675-104
C94
674
C95
IBM ARTIC960Hx Adapter Dynamic Random Access Memory (DRAM) test failure. Action: Use MAP0210 General problem resolution.
675-105
C94
674
C95
IBM ARTIC960Hx Adapter Memory Protection test failure. Action: Use MAP0210 General problem resolution.
675-106
C94
674
C95
IBM ARTIC960Hx Adapter Debug Port test failure. Action: Use MAP0210 General problem resolution.
675-107
C94
674
C95
Interface board wrap test failure. Action: Use MAP0210 General problem resolution.
675-110
C94
674
C95
IBM ARTIC960Hx Adapter Download Diagnostics test failure. Action: Use MAP0210 General problem resolution.
675-123
C94
674
C95
Interface board non-wrap test failure. Action: Use MAP0210 General problem resolution.
675-150
675
software
227
Device configuration failure. Action: Use MAP0210 General problem resolution.
675-151
675
software
227
Device driver indicates a hardware failure. Action: Use MAP0210 General problem resolution.
675-152 675 Failure and error in determining which type of IBM ARTIC960Hx Adapter. Action: Use MAP0210 General problem resolution.
675-153
675
software
C94
227
Error log analysis indicates an IBM ARTIC960Hx Adapter failure. Action: Use the errpt command to check error log. MAP0210 General problem resolution.
675-154
C94
675
C95
IBM ARTIC960Hx Adapter initialization failure. Action: Use MAP0210 General problem resolution.
675-155
C94
675
C95
IBM ARTIC960Hx Adapter initialization failure. Action: Use MAP0210 General problem resolution.
675-156
C94
675
C95
IBM ARTIC960Hx Adapter initialization failure. Action: Use MAP0210 General problem resolution.
675-157
C94
675
C95
Cable wrap test failure. Action: Use MAP0210 General problem resolution.
677-101 677 The Fibre Channel Adapter configuration failed. Action: Use MAP0210 General problem resolution.
677-102 677 The Reset test failed. Action: Use MAP0210 General problem resolution.
677-103 677 The Register test failed. Action: Use MAP0210 General problem resolution.
677-104 677 The SRAM test failed. Action: Use MAP0210 General problem resolution.
677-105 677 The Internal Wrap test failed. Action: Use MAP0210 General problem resolution.
677-106 677 The Gigabaud Link Module (GLM) Wrap Test Failure. Action: Use the MAP0210 General problem resolution The External Wrap test failed. Action: Use the MAP0210 General problem resolution.
677-107 677 The External Wrap test failed. Action: Use the MAP0210 General problem resolution.
677-109 221 Enhanced Error Handling Failure on EADs chip. Action: Use the MAP0210 General problem resolution.
677-110 677 Enhanced Error Handling Failure on adapter. Action: Use the MAP0210 General problem resolution.
677-201
677
221
The Configuration Register test failed. Action: Use the MAP0210 General problem resolution.
677-202
677
221
The Interrupt test failed. Action: Use MAP0210 General problem resolution.
677-203
677
221
The PCI Wrap test failed. Action: Use MAP0210 General problem resolution.
677-204
677
221
The DMA test failed. Action: Use MAP0210 General problem resolution.
677-205
677
221
I/O error on a read/write operation. Action: Use MAP0210 General problem resolution.
677-701
677
221
Error log analysis indicates that an error has occurred with the adapter. Action: Use the MAP0210 General problem resolution.
677-703 677 Error log analysis indicates that an unknown adapter error has occurred. Action: Use the MAP0210 General problem resolution.
677-704 677 Error log analysis indicates that an adapter error has occurred. Action: Use MAP0210 General problem resolution.
677-705 677 A parity error has been detected. The adapter must be replaced immediately. Failure to do so could result in data being read or written incorrectly. Action: Use MAP0210 General problem resolution.
677-706 677 A fatal hardware error has occurred. This adapter was successfully taken offline. It will remain offline until reconfigured or the system is rebooted. This adapter must be replaced and not brought back online. Failure to adhere to this action could result in data being read or written incorrectly or in the loss of data.
678-098 678 Tape drive indicates an error. Action: Use MAP0210 General problem resolution.
678-099
678
B88
Tape drive not found. Action: Use MAP0210 General problem resolution.
678-101 678 Timeout while attempting to communicate with SCSI device. Action: Use MAP0210 General problem resolution.
678-102 678 e SCSI device indicates busy. Action: Use MAP0210 General problem resolution.
678-103 678 The SCSI device indicates a reservation conflict. Action: Use MAP0210 General problem resolution.
678-104 678 The SCSI device indicates a check condition. Action: Use MAP0210 General problem resolution.
678-105 678 An error is detected in request sense data. Action: Use MAP0210 General problem resolution.
678-107 678 Sense data from the SCSI drive has unexpected data. Action: Use MAP0210 General problem resolution.
678-110 678 The Reserve command failed. Action: Use MAP0210 General problem resolution.
678-111 678 Invalid condition from the drive after a reserve. Action: Use MAP0210 General problem resolution.
678-112 678 The write-protect sensor test failed. Action: Use MAP0210 General problem resolution.
678-113 678 Invalid condition from drive after a request sense. Action: Use MAP0210 General problem resolution.
678-114 678 Timeout while attempting to communicate with the SCSI device. Action: Use MAP0210 General problem resolution.
678-120 678 The Inquiry command failed. Action: Use MAP0210 General problem resolution.
678-130
678
media
Load command failed. Action: Use MAP0210 General problem resolution.
678-134
B88
software
The adapter failed to configure. Action: Use MAP0210 General problem resolution.
678-135
678
media
The Unload command failed. Action: Use MAP0210 General problem resolution.
678-140 678 The Mode Select command failed. Action: Use MAP0210 General problem resolution.
678-150
678
media
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution.
678-160
678
media
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution.
678-161
678
B88
Invalid condition from the drive after a reserve. Action: Use MAP0210 General problem resolution.
678-163
678
B88
Invalid condition from the drive after a request sense. Action: Use MAP0210 General problem resolution.
678-164
678
B88
Timeout while attempting to communicate with the SCSI device. Action: Use MAP0210 General problem resolution.
678-165
678
B88
276
Write, Read and Compare Test failed. Action: Use MAP0210 General problem resolution.
678-166
678
B88
software
Unable to configure the device. Action: Use MAP0210 General problem resolution.
678-167
678
B88
An unexpected SCSI error occurred. Action: Use MAP0210 General problem resolution.
678-168
B88
software
The adapter failed to configure. Action: Use MAP0210 General problem resolution.
678-169
678
media
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution.
678-170
678
B88
media
The Read, Write and Compare test failed. Action: Use MAP0210 General problem resolution.
678-180
678
media
The Load command failed. Action: Use MAP0210 General problem resolution.
678-185
678
media
The Unload command failed. Action: Use MAP0210 General problem resolution
678-190 678 The Mode Select command failed. Action: Use MAP0210 General problem resolution
678-200
678
media
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution
678-201
678
B88
Error diagnosed from error log analysis. Action: Use MAP0210 General problem resolution.
678-210
678
B88
The device configuration failed. Action: Use MAP0210 General problem resolution
678-211
678
B88
The device open failed. Action: Use MAP0210 General problem resolution
678-220 678 The Release command failed. Action: Use MAP0210 General problem resolution
678-230 678 The Request Sense command failed. Action: Use MAP0210 General problem resolution
678-240 678 The Openx command failed. Action: Use MAP0210 General problem resolution
678-260 678 The device configuration failed. Action: Use MAP0210 General problem resolution.
678-261 678 The device open failed. Action: Use MAP0210 General problem resolution
678-300
678
software
The device configuration failed. Action: Use MAP0210 General problem resolution.
678-310
678
B88
software
SCSI adapter configuration failed. Action: Use MAP0210 General problem resolution.
678-320
678
media
Error log analysis indicates a failure. Action: Use MAP0210 General problem resolution.
678-411 to 678-423
678
B88
software
A reservation conflict occurred. Action: Use MAP0210 General problem resolution.
678-511 to 678-523
678
B88
The drive returned bad or non-extended sense data. Action: Use MAP0210 General problem resolution.
678-611 to 678-623
678
B88
software
An adapter or bus I/O error occurred. Action: Use MAP0210 General problem resolution.
678-711 to 678-723
678
B88
software
A device timeout error occurred. Action: Use MAP0210 General problem resolution.
679-xxx   See SCSI Devices SRNs (ssss-102 to ssss-640).
67B-100 67B POST failed: Catastrophic error detected. Action: Use MAP0210 General problem resolution.
67B-601 11A ELA indicates a low battery warning. Action: Use MAP0210 General problem resolution.
67B-602 67B ELA indicates a mesh violation - tamper. Action: Use MAP0210 General problem resolution.
67B-603 67B ELA indicates the coprocessor is held in a reset condition. Action: Use MAP0210 General problem resolution.
67B-604 67B ELA indicates a +3, +5, or +12 V over-voltage condition. Action: Use MAP0210 General problem resolution.
67B-605 67B ELA indicates an out-of-temperature specification. Action: Use MAP0210 General problem resolution.
67B-606 67B ELA indicates a X-ray or dead battery condition. Action: Use MAP0210 General problem resolution.
67B-607 67B ELA indicates: Intrusion latch. Action: Use MAP0210 General problem resolution.
67E-001
67E
221
Monitor/Cable
Adapter problem. Action: Use MAP0210 General problem resolution.
67E-002
67E
Monitor/Cable
Display problem. Action: Use MAP0210 General problem resolution.
67E-003
67E
software
Software error. Action: Use MAP0210 General problem resolution.
67E-004
67E
221
Monitor/Cable
The monitor test failed. Action: Use MAP0210 General problem resolution.
681-xxx   See SCSI Devices SRNs (ssss-102 to ssss-640).
682-111
682
B88
Unable to reserve device. Action: Use MAP0210 General problem resolution.
682-112
682
B88
Unable to do configuration. Action: Use MAP0210 General problem resolution.
682-113
682
B88
Unable to open the device driver. Action: Use MAP0210 General problem resolution.
682-121 682 The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution.
682-122 682 The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution.
682-123 682 The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution.
682-125
682
B88
The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution.
682-126 682 The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution.
682-127 682 The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution.
682-128 682 The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution
682-129 682 The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution.
682-150
682
Test Disc
A media error was detected. Action: Use MAP0210 General problem resolution.
682-151
682
B88
A command timeout was detected. Action: Use MAP0210 General problem resolution.
682-152 682 A command reservation conflict was detected. Action: Use MAP0210 General problem resolution.
682-162 682 The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution.
682-171 682 Unable to reserve device. Action: Use MAP0210 General problem resolution.
682-172 682 Unable to do configuration. Action: Use MAP0210 General problem resolution.
682-173 682 Unable to open device driver. Action: Use MAP0210 General problem resolution.
682-175 682 The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution.
682-198
682
B88
Undefined error detected. Action: Use MAP0210 General problem resolution.
682-199 682 Undefined error detected. Action: Use MAP0210 General problem resolution.
682-211 682 The LED test failed. Action: Use MAP0210 General problem resolution.
682-281 682 No tone during audio test. Action: Use MAP0210 General problem resolution.
682-301 682 Errors found during ELA. Action: Use MAP0210 General problem resolution.
682-302
682
B88
Errors found during ELA. Action: Use MAP0210 General problem resolution.
683-128 683 Error Log Analysis Indicates hardware failure VSS2105 Model B09. Action: Use MAP0210 General problem resolution.
686-114 686 The register verification test failed. Action: Use MAP0210 General problem resolution.
686-124 686 The adapter RAM verification test failed. Action: Use MAP0210 General problem resolution.
686-152
686
D57
The data wrap communication test failed. Action: Use MAP0210 General problem resolution.
686-153 686 The modem control line test failed. Action: Use MAP0210 General problem resolution.
686-252 686 The data wrap communication test failed. Action: Use MAP0210 General problem resolution.
686-253 686 The modem control line test failed. Action: Use MAP0210 General problem resolution.
686-501 686 Adapter Reset failed Action: Use MAP0210 General problem resolution.
686-511 686 Adapter to host memory test failed (byte tag test). Action: Use MAP0210 General problem resolution.
686-512 686 Adapter to host memory test failed (word tag test). Action: Use MAP0210 General problem resolution.
686-513 686 Adapter to host memory test failed (byte pattern test). Action: Use MAP0210 General problem resolution.
686-514 686 Adapter to host memory test failed (word pattern test). Action: Use MAP0210 General problem resolution.
686-521 686 Adapter BIOS POST CPU failed. Action: Use MAP0210 General problem resolution.
686-522 686 Adapter BIOS POST Checksum failed. Action: Use MAP0210 General problem resolution.
686-523 686 Adapter BIOS POST Timer failed. Action: Use MAP0210 General problem resolution.
686-524 686 Adapter BIOS POST RAM failed. Action: Use MAP0210 General problem resolution.
686-526 686 Adapter BIOS POST Async Ports failed. Action: Use MAP0210 General problem resolution.
686-527 686 Adapter BIOS test failed. Action: Use MAP0210 General problem resolution.
686-528 686 Adapter BIOS Reset failed. Action: Use MAP0210 General problem resolution.
686-529 686 Adapter BIOS Download failed. Action: Use MAP0210 General problem resolution.
686-531 686 Adapter BIOS Command failed. Action: Use MAP0210 General problem resolution.
686-533 686 Adapter BIOS Timer test failed. Action: Use MAP0210 General problem resolution.
686-534 686 Adapter BIOS RAM test failed. Action: Use MAP0210 General problem resolution.
686-541 686 Port async internal loopback test failed (general). Action: Use MAP0210 General problem resolution.
686-542 686 Port async internal loopback test failed (no response from the port). Action: Use MAP0210 General problem resolution.
686-551 686 Port async external loopback test failed (general). Action: Use MAP0210 General problem resolution.
686-552 686 Port async external loopback test failed (data signals). Action: Use MAP0210 General problem resolution.
686-553 686 Port async external loopback test failed (control signals). Action: Use MAP0210 General problem resolution.
686-554 686 Port async external loopback test failed (modem signals). Action: Use MAP0210 General problem resolution.
686-555 686 Port async external loopback test failed (no response from port). Action: Use MAP0210 General problem resolution.
686-901 to 686-920
software
686
An unexpected error occurred that can be attributed to software or hardware. Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use MAP 210 with a FFC of 686; otherwise, suspect a software problem.
686-921
software
686
The adapter failed to configure. Action: Use MAP0210 General problem resolution.
686-922 to 686-924
software
686
An unexpected error occurred that can be attributed to software or hardware. Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use MAP0210 General problem resolution with a FFC of 686; otherwise, suspect a software problem.
686-925 686 The adapter failed to configure software Action: Use MAP0210 General problem resolution.
686-926 to 686-950
software
686
An unexpected error occurred that can be attributed to software or hardware. Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network-based diagnostics, use MAP0210 General problem resolution with a FFC of 686; otherwise, suspect a software problem.
687-111 687 The controller register test failed. Action: Use MAP0210 General problem resolution.
687-114 687 The register verification test failed. Action: Use MAP0210 General problem resolution.
687-124 687 The adapter RAM verification test failed. Action: Use MAP0210 General problem resolution.
687-144 687 The sync line test failed. Action: Use MAP0210 General problem resolution.
687-152
837
684
687
152
The data wrap communication test failed. Action: Use MAP0210 General problem resolution.
687-153 687 The modem control line test failed. Action: Use MAP0210 General problem resolution.
687-244 687 The sync line test failed. Action: Use MAP0210 General problem resolution.
687-252 687 The data wrap communication test failed. Action: Use MAP0210 General problem resolution.
687-253 687 The modem control line test failed. Action: Use MAP0210 General problem resolution.
687-501 687 Adapter Reset failed. Action: Use MAP0210 General problem resolution.
687-502 687 Adapter Fuse failed. Action: Use MAP0210 General problem resolution.
687-511 687 Adapter to host memory test failed (byte tag test). Action: Use MAP0210 General problem resolution.
687-512 687 Adapter to host memory test failed (word tag test). Action: Use MAP0210 General problem resolution.
687-513 687 Adapter to host memory test failed (byte pattern test). Action: Use MAP0210 General problem resolution.
687-514 687 Adapter to host memory test failed (word pattern test). Action: Use MAP0210 General problem resolution.
687-521 687 Adapter BIOS POST CPU failed. Action: Use MAP0210 General problem resolution.
687-522 687 Adapter BIOS POST Checksum failed. Action: Use MAP0210 General problem resolution.
687-523 687 Adapter BIOS POST Timer failed. Action: Use MAP0210 General problem resolution.
687-524 687 Adapter BIOS POST RAM failed. Action: Use MAP0210 General problem resolution.
687-525 687 Adapter BIOS POST Sync Line failed. Action: Use MAP0210 General problem resolution.
687-527 687 Adapter BIOS test failed. Action: Use MAP0210 General problem resolution.
687-528 687 Adapter BIOS Reset failed. Action: Use MAP0210 General problem resolution.
687-529 687 Adapter BIOS Download failed. Action: Use MAP0210 General problem resolution.
687-531 687 Adapter BIOS Command failed. Action: Use MAP0210 General problem resolution.
687-533 687 Adapter BIOS Timer test failed. Action: Use MAP0210 General problem resolution.
687-534 687 Adapter BIOS RAM test failed. Action: Use MAP0210 General problem resolution.
687-541 687 Port sync internal loopback test failed. Action: Use MAP0210 General problem resolution.
687-551 687 Port sync external loopback test failed. Action: Use MAP0210 General problem resolution.
687-600 687 232RAN status test failed. Action: Use MAP0210 General problem resolution.
687-700 687 422RAN status test failed. Action: Use MAP0210 General problem resolution.
687-901 to 687-920
software
687
An unexpected error occurred that can be attributed to software or hardware. Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network-based diagnostics, use MAP0210 General problem resolution with a FFC of 687; otherwise, suspect a software problem.
687-921
software
687
The adapter failed to configure. Action: Use MAP0210 General problem resolution.
687-922 to 687-924
software
687
An unexpected error occurred that can be attributed to software or hardware. Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network-based diagnostics, use MAP0210 General problem resolution. with a FFC of 687; otherwise, suspect a software problem.
687-925
software
687
The adapter failed to configure. Action: Use MAP0210 General problem resolution.
687-926 to 687-950
software
687
An unexpected error occurred that can be attributed to software or hardware. Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use MAP0210 General problem resolution with a FFC of 687; otherwise, suspect a software problem.
689-xxx   See SCSI Devices SRNs (ssss-102 to ssss-640).
68C-101 68C Timeout while attempting to communicate with SCSI device. Action: Use MAP0210 General problem resolution.
68C-102 68C The SCSI device indicates busy. Action: Use MAP0210 General problem resolution.
68C-103 68C The SCSI device indicates a reservation conflict. Action: Use MAP0210 General problem resolution.
68C-104 68C The SCSI device indicates a check condition. Action: Use MAP0210 General problem resolution.
68C-105 68C An error is detected in request sense data. Action: Use MAP0210 General problem resolution.
68C-107 68C Sense data from the SCSI drive has unexpected data. Action: Use MAP0210 General problem resolution.
68C-110 68C The Reserve command failed. Action: Use MAP0210 General problem resolution.
68C-111 68C Invalid condition from the drive after a reserve. Action: Use MAP0210 General problem resolution.
68C-112 68C The write-protect sensor test failed. Action: Use MAP0210 General problem resolution.
68C-113 68C Invalid condition from drive after a request sense. Action: Use MAP0210 General problem resolution.
68C-114 68C Timeout while attempting to communicate with the SCSI device. Action: Use MAP0210 General problem resolution.
68C-120 68C The Inquiry command failed. Action: Use MAP0210 General problem resolution.
68C-130
68C
media
The Load command failed. Action: Use MAP0210 General problem resolution.
68C-134
B88
software
The adapter failed to configure. Action: Use MAP0210 General problem resolution.
68C-135
68C
media
The Unload command failed. Action: Use MAP0210 General problem resolution.
68C-140 68C The Mode Select command failed. Action: Use MAP0210 General problem resolution.
68C-150
68C
media
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution.
68C-160
68C
media
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution.
68C-161
68C
B88
Invalid condition from the drive after a reserve. Action: Use MAP0210 General problem resolution.
68C-163
68C
B88
Invalid condition from the drive after a request sense. Action: Use MAP0210 General problem resolution.
68C-164
68C
B88
Timeout while attempting to communicate with the SCSI device. Action: Use MAP0210 General problem resolution.
68C-165
68C
B88
276
Write, Read and Compare Test failed. Action: Use MAP0210 General problem resolution.
68C-166
68C
B88
software
Unable to configure the device. Action: Use MAP0210 General problem resolution.
68C-167
68C
B88
An unexpected SCSI error occurred. Action: Use MAP0210 General problem resolution.
68C-168
B88
software
The adapter failed to configure. Action: Use MAP0210 General problem resolution.
68C-169
68C
media
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution.
68C-170
68C
B88
media
The Read, Write and Compare test failed. Action: Use MAP0210 General problem resolution.
68C-180
68C
media
The Load command failed. Action: Use MAP0210 General problem resolution.
68C-185
68C
media
The Unload command failed. Action: Use MAP0210 General problem resolution.
68C-190 68C The Mode Select command failed. Action: Use MAP0210 General problem resolution.
68C-200
68C
media
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution.
68C-201
68C
B88
Error diagnosed from error log analysis. Action: Use MAP0210 General problem resolution.
68C-210
68C
B88
The device configuration failed. Action: Use MAP0210 General problem resolution.
68C-211
68C
B88
The device open failed. Action: Use MAP0210 General problem resolution.
68C-220 68C The Release command failed. Action: Use MAP0210 General problem resolution.
68C-230 68C The Request Sense command failed. Action: Use MAP0210 General problem resolution.
68C-240 68C The Openx command failed. Action: Use MAP0210 General problem resolution.
68C-260 68C The device configuration failed. Action: Use MAP0210 General problem resolution.
68C-261 68C The device open failed. Action: Use MAP0210 General problem resolution.
68C-300
68C
software
The device configuration failed. Action: Use MAP0210 General problem resolution.
68C-310
B88
68C
software
SCSI adapter configuration failed. Action: Use MAP0210 General problem resolution.
68C-320
68C
media
Error log analysis indicates a failure. Action: Use MAP0210 General problem resolution.
68C-411 to 68C-423
B88
68C
software
A reservation conflict occurred. Action: Use MAP0210 General problem resolution.
68C-511 to 68C-523
B88
68C
The drive returned bad or non-extended sense data. Action: Use MAP0210 General problem resolution.
68C-611 to 68C-623
B88
68C
software
An adapter or bus I/O error occurred. Action: Use MAP0210 General problem resolution.
68C-711 to 68C-723
B88
68C
software
A device timeout error occurred. Action: Use MAP0210 General problem resolution.
68E-001
Software
68E
Software error. Action: Use MAP0210 General problem resolution.
68E-002
Software
68E
Adapter failure. Action: Use MAP0210 General problem resolution.
68E-003
68E
227
Adapter failure. Action: Use MAP0210 General problem resolution.
68E-004
68E
Monitor/Cable
Display failure. Action: Use MAP0210 General problem resolution.
68E-005
68E
227
Monitor/Cable
Adapter failure. Action: Use MAP0210 General problem resolution.
690-xxx
691
227
See SCSI Devices SRNs (ssss-102 to ssss-640).
692-110 692 The Reserve command failed. Action: Use MAP0210 General problem resolution.
692-120 692 The Inquiry command failed. Action: Use MAP0210 General problem resolution.
692-130
692
media
The Load command failed. Action: Use MAP0210 General problem resolution.
692-135
692
media
The Unload command failed. Action: Use MAP0210 General problem resolution.
692-140 692 The Mode Select command failed. Action: Use MAP0210 General problem resolution.
692-150
692
media
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution.
692-160
692
media
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution.
692-169
692
media
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution.
692-170
692
B88
media
The Read, Write and Compare test failed. Action: Use MAP0210 General problem resolution.
692-180
692
media
The Load command failed. Action: Use MAP0210 General problem resolution.
692-185
692
media
The Unload command failed. Action: Use MAP0210 General problem resolution.
692-190 692 The Mode Select command failed. Action: Use MAP0210 General problem resolution.
692-200
692
media
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution.
692-210
692
B88
The device configuration failed. Action: Use MAP0210 General problem resolution.
692-220 692 The Release command failed. Action: Use MAP0210 General problem resolution.
692-230 692 The Request Sense command failed. Action: Use MAP0210 General problem resolution.
692-240 692 The Openx command failed. Action: Use MAP0210 General problem resolution.
692-300
692
software
The device configuration failed. Action: Use MAP0210 General problem resolution.
692-310
B88
692
software
SCSI adapter configuration failed. Action: Use MAP0210 General problem resolution.
692-320
692
media
Error log analysis indicates a failure. Action: Use MAP0210 General problem resolution.
692-411 to 692-423
B88
692
software
A reservation conflict occurred. Action: Use MAP0210 General problem resolution.
692-511 to 692-523
B88
692
The drive returned bad or non-extended sense data. Action: Use MAP0210 General problem resolution.
692-611 to 692-623
B88
692
software
An adapter or bus I/O error occurred. Action: Use MAP0210 General problem resolution.
692-711 to 692-723
B88
692
software
A device timeout error occurred. Action: Use MAP0210 General problem resolution.
697-103
697
software
227
Charm software reset failure. Action: Use MAP0210 General problem resolution.
697-104
697
software
227
Packet memory error. Action: Use MAP0210 General problem resolution.
697-105
697
software
227
Control memory failure. Action: Use MAP0210 General problem resolution.
697-106 697 Link-R detected bad parity. Action: Use MAP0210 General problem resolution.
697-107 697 Suni detected bad parity. Action: Use MAP0210 General problem resolution.
697-108 697 Suni initialization failure. Action: Use MAP0210 General problem resolution.
697-109
Wrap Plug
697
Loss of light detected in Link test. Action: Check wrap plug installation. Action: Use MAP0210 General problem resolution.
697-10B
Wrap Plug
697
External Loopback failed Action: Check wrap plug installation. Action: Use MAP0210 General problem resolution.
697-10C
697
software
227
Internal Loopback failed. Action: Use MAP0210 General problem resolution.
697-10D
697
software
227
DMS failed. Action: Use MAP0210 General problem resolution.
697-121 697 Adapter memory test failure. Action: Use MAP0210 General problem resolution.
697-122 697 Adapter checksum failure. Action: Use MAP0210 General problem resolution.
697-123 697 Internal wrap test failure Action: Use MAP0210 General problem resolution.
697-124 697 External wrap test failure Action: Use MAP0210 General problem resolution.
697-125 221 Enhanced Error Handling failure on bus Action: Use MAP0210 General problem resolution.
697-126 221 Enhanced Error Handling failure on EADS chip Action: Use MAP0210 General problem resolution.
697-127 697 Enhanced Error Handling failure on adapter Action: Use MAP0210 General problem resolution.
697-1FF
697
software
227
EPROM checksum failed Action: Use MAP0210 General problem resolution.
697-200
697
software
227
Klog error Action: Use MAP0210 General problem resolution.
697-201
697
software
227
ASL error Action: Use MAP0210 General problem resolution.
697-202
697
software
227
ODM Initialization error Action: Use MAP0210 General problem resolution.
697-203
697
software
227
Diagnostic configuration failure. Action: Use MAP0210 General problem resolution.
697-205
697
software
227
Error in diag open. Action: Use MAP0210 General problem resolution.
697-206
697
221
Error in releasing adapter Action: Use MAP0210 General problem resolution.
697-221
697
221
Hardware failure opening the adapter Action: Use MAP0210 General problem resolution.
697-222
697
221
Enhanced Error Handling failure opening the adapter Action: Use MAP0210 General problem resolution.
697-223
697
221
Interrupt test failure Action: Use MAP0210 General problem resolution.
697-224
697
221
Adapter DMA test failure Action: Use MAP0210 General problem resolution.
697-701
697
221
Error Log Analysis indicates an I/O failure on the adapter. Action: Use MAP0210 General problem resolution.
697-702 697 Error Log Analysis indicates an unrecovered interrupt error. Action: Use MAP0210 General problem resolution.
698-100
697
software
227
Charm memory write failure. Action: Use MAP0210 General problem resolution.
698-101
697
software
227
Charm memory read failure. Action: Use MAP0210 General problem resolution.
698-102
697
software
227
PCI configuration register write failure. Action: Use MAP0210 General problem resolution.
698-103
697
software
227
Charm software reset failure. Action: Use MAP0210 General problem resolution.
698-104
697
software
227
Packet memory error Action: Use MAP0210 General problem resolution.
698-105
697
software
227
Control memory failure. Action: Use MAP0210 General problem resolution.
698-106 698 Link-R detected bad parity. Action: Use MAP0210 General problem resolution.
698-107 698 Suni detected bad parity. Action: Use MAP0210 General problem resolution.
698-108 698 Suni initialization failure. Action: Use MAP0210 General problem resolution.
698-109
Wrap Plug
698
Loss of light detected in Link test. Action: Check wrap plug installation. Action: Use MAP0210 General problem resolution.
698-10B
Wrap Plug
698
External Loopback failed Action: Check wrap plug installation. Action: Use MAP0210 General problem resolution.
698-10C
698
software
227
Internal Loopback failed. Action: Use MAP0210 General problem resolution.
698-10D
698
software
227
DMS failed. Action: Use MAP0210 General problem resolution.
698-121 698 Adapter memory test failure. Action: Use MAP0210 General problem resolution.
698-122 698 Adapter checksum failure. Action: Use MAP0210 General problem resolution.
698-123 698 Internal wrap test failure. Action: Use MAP0210 General problem resolution.
698-124 698 External wrap test failure. Action: Use MAP0210 General problem resolution.
698-125 221 Enhanced Error Handling failure on bus. Action: Use MAP0210 General problem resolution.
698-126 221 Enhanced Error Handling failure on EADS chip. Action: Use MAP0210 General problem resolution.
698-127 698 Enhanced Error Handling failure on adapter. Action: Use MAP0210 General problem resolution.
698-1FF
698
software
227
EPROM checksum failed. Action: Use MAP0210 General problem resolution.
698-200
698
software
227
Klog error. Action: Use MAP0210 General problem resolution.
698-201
698
software
227
ASL error. Action: Use MAP0210 General problem resolution.
698-202
698
software
227
ODM Initialization error. Action: Use MAP0210 General problem resolution.
698-203
698
software
227
Diagnostic configuration failure. Action: Use MAP0210 General problem resolution.
698-205
698
software
227
Error in diag open. Action: Use MAP0210 General problem resolution.
698-206
698
software
227
Error in releasing adapter. Action: Use MAP0210 General problem resolution.
698-221
698
221
Hardware failure opening the adapter. Action: Use MAP0210 General problem resolution.
698-222
698
221
Enhanced Error Handling failure opening the adapter. Action: Use MAP0210 General problem resolution.
698-223
698
221
Interrupt test failure. Action: Use MAP0210 General problem resolution.
698-224
698
221
Adapter DMA test failure. Action: Use MAP0210 General problem resolution.
698-701
698
221
Error Log Analysis indicates an I/O failure on the adapter. Action: Use MAP0210 General problem resolution.
698-702 698 Error Log Analysis indicates an unrecovered interrupt error. Action: Use MAP0210 General problem resolution.
69b-101 69b EPROM test failure. Action: Use MAP0210 General problem resolution.
69b-102 69b Adapter SDRAM failure. Action: Use MAP0210 General problem resolution.
69b-103 69b Adapter checksum failure. Action: Use MAP0210 General problem resolution.
69b-104 69b Adapter memory test failure. Action: Use MAP0210 General problem resolution.
69b-105 69b Adapter buffer test failure. Action: Use MAP0210 General problem resolution.
69b-106 69b Adapter cache test failure. Action: Use MAP0210 General problem resolution.
69b-107 69b Internal loopback test failure. Action: Use MAP0210 General problem resolution.
69b-108 69b External wrap test failure. Action: Use MAP0210 General problem resolution.
69b-109 221 Enhanced Error Handling failure on bus. Action: Use MAP0210 General problem resolution.
69b-110 221 Enhanced Error Handling failure on Eads chip. Action: Use MAP0210 General problem resolution.
69b-111 69b Enhanced Error Handling failure on adapter.Action: Use MAP0210 General problem resolution.
69b-201
69b
221
Hardware failure opening adapter. Action: Use MAP0210 General problem resolution.
69b-202
69b
221
Interrupt test failure. Action: Use MAP0210 General problem resolution.
69b-203
69b
221
Adapter DMA test failure. Action: Use MAP0210 General problem resolution.
69b-204
69b
221
Enhanced error handling failure opening the adapter. Action: Use MAP0210 General problem resolution.
69b-701 69b Error Log Analysis indicates an I/O failure on the adapter. Action: Use MAP0210 General problem resolution.
69d-101 69d EPROM test failure. Action: Use MAP0210 General problem resolution.
69d-102 69d Adapter SDRAM failure. Action: Use MAP0210 General problem resolution.
69d-103 69d Adapter checksum failure. Action: Use MAP0210 General problem resolution.
69d-104 69d Adapter memory test failure. Action: Use MAP0210 General problem resolution.
69d-105 69d Adapter buffer test failure. Action: Use MAP0210 General problem resolution.
69d-106 69d Adapter cache test failure. Action: Use MAP0210 General problem resolution.
69d-107 69d Internal loopback test failure. Action: Use MAP0210 General problem resolution.
69d-108 69d External wrap test failure. Action: Use MAP0210 General problem resolution.
69d-109 221 Enhanced Error Handling failure on bus. Action: Use MAP0210 General problem resolution.
69d-110 221 Enhanced Error Handling failure on Eads chip. Action: Use MAP0210 General problem resolution.
69d-111 69d Enhanced Error Handling failure on adapter. Action: Use MAP0210 General problem resolution.
69d-201
69d
221
Hardware failure opening adapter. Action: Use MAP0210 General problem resolution.
69d-202
69d
221
Interrupt test failure. Action: Use MAP0210 General problem resolution.
69d-203
69d
221
Adapter DMA test failure. Action: Use MAP0210 General problem resolution.
69d-204
69d
221
Enhanced error handling failure opening the adapter. Action: Use MAP0210 General problem resolution.
69d-701 69d Error Log Analysis indicates an I/O failure on the adapter. Action: Use MAP0210 General problem resolution.