SRNs 900-001 through 9CC-xxx
Replace FRU parts in the order by which the "Failing Function Codes" are listed. Go to Failing function code list to access the failing function codes.
Note: Some SRNs in this chapter may
have 4 rather than 3 digits after the dash (-).
| Service Request Number | Failing Function Codes | Description/Action (Unless indicated otherwise use MAP0210 General problem resolution.) |
|---|---|---|
| 901-xxx | Vendor SCSI device problem. Refer to the service documentation for this device. Action: Use MAP0210 General problem resolution. | |
| 902-xxx | Vendor display problem. Refer to the service documentation for this display. Action: Use MAP0210 General problem resolution. | |
| 903-xxx | Vendor Async device problem. Refer to the service documentation for this device. Action: Use MAP0210 General problem resolution. | |
| 904-xxx | Vendor Parallel device problem. Refer to the service documentation for this device. Action: Use MAP0210 General problem resolution. | |
| 905-xxx | Vendor device problem. Refer to the service documentation for this device. Action: Use MAP0210 General problem resolution. | |
| 912-XXX
to 913-XXX |
See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 914-110 | 914 | The Reserve command failed. Action: Use MAP0210 General problem resolution. |
| 914-120 | 914 | The Inquiry command failed. Action: Use MAP0210 General problem resolution. |
| 914-130 | 914
media |
The Load command failed. Action: Use MAP0210 General problem resolution. |
| 914-135 | 914
media |
The Unload command failed. Action: Use MAP0210 General problem resolution. |
| 914-140 | 914 | The Mode Select command failed. Action: Use MAP0210 General problem resolution. |
| 914-150 | 914
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution. |
| 914-160 | 914
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution. |
| 914-170 | 914
B88 media |
The Read, Write and Compare test failed. Action: Use MAP0210 General problem resolution. |
| 914-180 | 914
media |
The Load command failed. Action: Use MAP0210 General problem resolution. |
| 914-185 | 914
media |
The Unload command failed. Action: Use MAP0210 General problem resolution. |
| 914-190 | 914 | The Mode Select command failed. Action: Use MAP0210 General problem resolution. |
| 914-200 | 914
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution. |
| 914-210 | 914
B88 |
The device configuration failed. Action: Use MAP0210 General problem resolution. |
| 914-220 | 914 | The Release command failed. Action: Use MAP0210 General problem resolution. |
| 914-230 | 914 | The Request Sense command failed. Action: Use MAP0210 General problem resolution. |
| 914-240 | 914 | The Openx command failed. Action: Use MAP0210 General problem resolution. |
| 914-300 | 914
software |
The device configuration failed. Action: Use MAP0210 General problem resolution. |
| 914-310 | B88
914 software |
SCSI adapter configuration failed. Action: Use MAP0210 General problem resolution. |
| 914-320 | 914
media |
Error log analysis indicates a failure. Action: Use MAP0210 General problem resolution. |
| 914-411
to 914-423 |
914
B88 software |
A reservation conflict occurred. Action: Use MAP0210 General problem resolution. |
| 914-511
to 914-523 |
914
B88 |
The drive returned bad or non-extended sense data. Action: Use MAP0210 General problem resolution. |
| 914-611
to 914-623 |
914
B88 software |
An adapter or bus I/O error occurred. Action: Use MAP0210 General problem resolution. |
| 914-711
to 914-723 |
914
B88 software |
A device timeout error occurred. Action: Use MAP0210 General problem resolution. |
| 915-110 | 915 | The Reserve command is corrupted. Action: Use MAP0210 General problem resolution. |
| 915-120 | 915 | The Inquiry command failed. Action: Use MAP0210 General problem resolution. |
| 915-130 | 915
media |
The Load command failed. Action: Use MAP0210 General problem resolution. |
| 915-135 | 915
media |
The Unload command failed. Action: Use MAP0210 General problem resolution. |
| 915-140 | 915 | The Mode Select command failed. Action: Use MAP0210 General problem resolution. |
| 915-150 | 915
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution. |
| 915-160 | 915
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution. |
| 915-169 | 915
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution. |
| 915-170 | 915
B88 media |
The Read, Write and Compare test failed. Action: Use MAP0210 General problem resolution. |
| 915-180 | 915
media |
The Load command failed. Action: Use MAP0210 General problem resolution. |
| 915-185 | 915
media |
The Unload command failed. Action: Use MAP0210 General problem resolution. |
| 915-190 | 915 | The Mode Select command failed. Action: Use MAP0210 General problem resolution. |
| 915-200 | 915
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution. |
| 915-210 | 915
B88 |
The device configuration failed. Action: Use MAP0210 General problem resolution. |
| 915-220 | 915 | The Replace command failed. Action: Use MAP0210 General problem resolution. |
| 915-230 | 915 | The Request Sense command failed. Action: Use MAP0210 General problem resolution. |
| 915-240 | 915 | The Openx command failed. Action: Use MAP0210 General problem resolution. |
| 915-300 | 915
software |
The device configuration failed. Action: Use MAP0210 General problem resolution. |
| 915-310 | B88
915 software |
SCSI adapter configuration failed. Action: Use MAP0210 General problem resolution. |
| 915-320 | 915
media |
Error log analysis indicates a failure. Action: Use MAP0210 General problem resolution. |
| 915-411
to 915-423 |
915
B88 software |
A reservation conflict occurred. Action: Use MAP0210 General problem resolution. |
| 915-511
to 915-523 |
915
B88 |
The drive returned bad or non-extended sense data. Action: Use MAP0210 General problem resolution. |
| 915-611
to 915-623 |
915
B88 software |
An adapter or bus I/O error occurred. Action: Use MAP0210 General problem resolution. |
| 915-711
to 915-723 |
915
B88 software |
A device timeout error occurred. Action: Use MAP0210 General problem resolution. |
| 917-102 | 917
B88 |
An unrecoverable media error. Action: Use MAP0210 General problem resolution. |
| 917-104 | 917 | The motor failed to restart. Action: Use MAP0210 General problem resolution. |
| 917-105 | 917 | The drive did not become ready. Action: Use MAP0210 General problem resolution. |
| 917-106 | 917 | The electronics card test failed. Action: Use MAP0210 General problem resolution. |
| 917-108 | 917 | The bus test failed. Action: Use MAP0210 General problem resolution. |
| 917-110 | 917 | The media format is corrupted. Action: Use MAP0210 General problem resolution. |
| 917-112 | 917 | The diagnostic test failed. Action: Use MAP0210 General problem resolution. |
| 917-114 | 917 | An unrecoverable hardware error. Action: Use MAP0210 General problem resolution. |
| 917-116 | A protocol error. Action: Check the levels of the device, adapter, diagnostic software, and application software to ensure they are all compatible. If you do not find a problem, call your support person. Use MAP0210 General problem resolution. | |
| 917-117 | 917 | A write-protect error occurred. Action: Use MAP0210 General problem resolution. |
| 917-118 | 917
B88 |
A SCSI command timeout. Action: Use MAP0210 General problem resolution. |
| 917-120 | 917 | A SCSI busy or command error. Action: Use MAP0210 General problem resolution. |
| 917-122 | 917 | A SCSI reservation conflict error. Action: Use MAP0210 General problem resolution. |
| 917-124 | 917 | A SCSI check condition error. Action: Use MAP0210 General problem resolution. |
| 917-126 | 917
B88 |
A software error was caused by a hardware failure. Action: Use MAP0210 General problem resolution. |
| 917-128 | 917 | The error log analysis indicates a hardware failure. Action: Use MAP0210 General problem resolution. |
| 917-129 | 917 | Error log analysis indicates a SCSI bus problem. Action: Use MAP0210 General problem resolution. |
| 917-130 | 917
B88 |
Error log analysis indicates a problem reported by the disk drive's self-monitoring function. Action: Use MAP0210 General problem resolution. |
| 917-132 | 917 | A disk drive hardware error occurred. Action: Use MAP0210 General problem resolution. |
| 917-133 | 917 | Use the subsystem guide to complete diagnostics. Action: Use MAP0210 General problem resolution. |
| 917-134 | B88
software |
The adapter failed to configure. Action: Use MAP0210 General problem resolution. |
| 917-135 | 917
B88 software |
The device failed to configure. Action: Use MAP0210 General problem resolution. |
| 917-136 | 917 | The certify operation failed. Action: Use MAP0210 General problem resolution. |
| 917-137 | 917
B88 190 |
Unit attention condition has occurred on the Send Diagnostic command. Action: Use MAP0210 General problem resolution. |
| 917-138 | 190 | Error log indicates that the disk is operating at higher than recommended temperatures. Action: Use MAP0210 General problem resolution. |
| 917-139 | 917 | Error configuring or opening device. Action: Use MAP0210 General problem resolution. |
| 917-640 | 640 | Error Log Analysis indicates a path error. Action: Use MAP0210 General problem resolution. |
| 918-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 921-101 | 821 | An unexpected adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 921-102 | 921
821 |
An unexpected device or adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 921-103 | 921
821 |
The keyboard reset failed. Action: Use MAP0210 General problem resolution. |
| 921-104 | 921 | Unknown keyboard. Action: Use MAP0210 General problem resolution. |
| 921-105 | 921
821 |
The keyboard light-on test failed. Action: Use MAP0210 General problem resolution. |
| 921-106 | 921
821 |
The keyboard light-off test failed. Action: Use MAP0210 General problem resolution. |
| 921-201 | 821 | An unexpected adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 921-202 | 921
821 |
An unexpected device or adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 921-203 | 921
821 |
The read keyboard ID test failed. Action: Use MAP0210 General problem resolution. |
| 921-204 | 921 | The keyboard layout ID test failed. Action: Use MAP0210 General problem resolution. |
| 921-205 | 921
821 |
The keyboard echo test failed. Action: Use MAP0210 General problem resolution. |
| 921-206 | 921
821 |
The select scan code set test failed. Action: Use MAP0210 General problem resolution. |
| 921-301 | 821 | An unexpected adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 921-302 | 921
821 |
An unexpected device or adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 921-303 | 921 | An error occurred in turning on the lamps. Action: Use MAP0210 General problem resolution. |
| 921-304 | 921 | An error occurred in turning off the lamps. Action: Use MAP0210 General problem resolution. |
| 921-401 | 821 | An unexpected adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 921-402 | 921
821 |
An unexpected device or adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 921-403 | 921 | Unable to recognize the keyboard. Action: Use MAP0210 General problem resolution. |
| 921-404 | 921
821 |
The keyboard is failing. Action: Use MAP0210 General problem resolution. |
| 921-501 | 821 | An unexpected adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 921-502 | 921
821 |
An unexpected device or adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 921-503 | 921 | The auto-click cannot be disabled. Action: Use MAP0210 General problem resolution. |
| 921-504 | 921 | The auto-click cannot be enabled. Action: Use MAP0210 General problem resolution. |
| 921-505 | 921 | Unable to recognize the keyboard. Action: Use MAP0210 General problem resolution. |
| 921-601 | 821 | An unexpected adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 921-602 | 921
821 |
An unexpected device or adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 921-603 | 921 | The speaker test failed. Action: Use MAP0210 General problem resolution. |
| 921-701 | 921
821 |
Error configuring the device. Action: Use MAP0210 General problem resolution. |
| 921-901 | 821 | The error log analysis indicates an adapter failure. Action: Use MAP0210 General problem resolution. |
| 921-902 | 921 821 | The error log analysis indicates a device failure. Action: Use MAP0210 General problem resolution. |
| 921-903 | 921
821 |
The error log analysis indicates an unknown failure. Action: Use MAP0210 General problem resolution. |
| 922-101 | 821 | An unexpected adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 922-102 | 922
821 |
An unexpected device or adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 922-103 | 922
821 |
The keyboard reset failed. Action: Use MAP0210 General problem resolution. |
| 922-104 | 922 | Unknown keyboard. Action: Use MAP0210 General problem resolution. Action: Use MAP0210 General problem resolution. |
| 922-105 | 922
821 |
The keyboard light-on test failed. Action: Use MAP0210 General problem resolution. |
| 922-106 | 922
821 |
The keyboard light-off test failed. Action: Use MAP0210 General problem resolution. |
| 922-201 | 821 | An unexpected adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 922-202 | 922
821 |
An unexpected device or adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 922-203 | 922
821 |
The read keyboard id test failed. Action: Use MAP0210 General problem resolution. |
| 922-204 | 922 | The keyboard layout id test failed. Action: Use MAP0210 General problem resolution. |
| 922-205 | 922
821 |
The keyboard echo test failed. Action: Use MAP0210 General problem resolution. |
| 922-206 | 922
821 |
The select scan code set test failed. Action: Use MAP0210 General problem resolution. |
| 922-301 | 821 | An unexpected adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 922-302 | 922
821 |
An unexpected device or adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 922-303 | 922 | An error occurred in turning on the lamps. Action: Use MAP0210 General problem resolution. |
| 922-304 | 922 | An error occurred in turning off the lamps. Action: Use MAP0210 General problem resolution. |
| 922-401 | 821 | An unexpected adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 922-402 | 922
821 |
An unexpected device or adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 922-403 | 922 | The keyboard is failing. Action: Use MAP0210 General problem resolution. |
| 922-404 | 922
821 |
Unable to recognize the keyboard. Action: Use MAP0210 General problem resolution. |
| 922-501 | 821 | An unexpected adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 922-502 | 922
821 |
An unexpected device or adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 922-503 | 921 | The auto-click cannot be disabled. Action: Use MAP0210 General problem resolution. |
| 922-504 | 922 | The auto-click cannot be enabled. Action: Use MAP0210 General problem resolution. |
| 922-505 | 922 | Unable to recognize the keyboard. Action: Use MAP0210 General problem resolution. |
| 922-601 | 821 | An unexpected adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 922-602 | 922
821 |
An unexpected device or adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 922-603 | 922 | The speaker test failed. Action: Use MAP0210 General problem resolution. |
| 922-701 | 922
821 |
Error configuring the device. Action: Use MAP0210 General problem resolution. |
| 922-901 | 821 | The error log indicates an adapter failed. Action: Use MAP0210 General problem resolution. |
| 922-902 | 922
821 |
The error log indicates a device failed. Action: Use MAP0210 General problem resolution. |
| 922-903 | 922
821 |
The error log analysis indicates an unknown failure. Action: Use MAP0210 General problem resolution. |
| 923-101 | 821 | An unexpected adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 923-102 | 923
821 |
An unexpected device or adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 923-103 | 923
821 |
The keyboard reset failed. Action: Use MAP0210 General problem resolution. |
| 923-104 | 923 | Unknown keyboard. Action: Use MAP0210 General problem resolution. |
| 923-105 | 923
821 |
The keyboard light-on test failed. Action: Use MAP0210 General problem resolution. |
| 923-106 | 923
821 |
The keyboard light-off test failed. Action: Use MAP0210 General problem resolution. |
| 923-201 | 821 | An unexpected adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 923-202 | 923
821 |
An unexpected device or adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 923-203 | 923
821 |
The read keyboard id test failed. Action: Use MAP0210 General problem resolution. |
| 923-204 | 923 | The keyboard layout id test failed. Action: Use MAP0210 General problem resolution. |
| 923-205 | 923
821 |
The keyboard echo test failed. Action: Use MAP0210 General problem resolution. |
| 923-206 | 923
821 |
The select scan code set test failed. Action: Use MAP0210 General problem resolution. |
| 923-301 | 821 | An unexpected adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 923-302 | 923
821 |
An unexpected device or adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 923-303 | 923 | An error occurred in turning on the lamps. Action: Use MAP0210 General problem resolution. |
| 923-304 | 923 | An error occurred in turning off the lamps. Action: Use MAP0210 General problem resolution. |
| 923-401 | 821 | An unexpected adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 923-402 | 923
821 |
An unexpected device or adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 923-403 | 923 | The keyboard is failing. Action: Use MAP0210 General problem resolution. |
| 923-404 | 923
821 |
Unable to recognize the keyboard. Action: Use MAP0210 General problem resolution. |
| 923-501 | 821 | An unexpected adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 923-502 | 923
821 |
An unexpected device or adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 923-503 | 923 | The auto-click cannot be disabled. Action: Use MAP0210 General problem resolution. |
| 923-504 | 923 | The auto-click cannot be enabled. Action: Use MAP0210 General problem resolution. |
| 923-505 | 923 | Unable to recognize the keyboard. Action: Use MAP0210 General problem resolution. |
| 923-601 | 821 | An unexpected adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 923-602 | 923
821 |
An unexpected device or adapter error occurred. Action: Use MAP0210 General problem resolution. |
| 923-603 | 923 | The speaker test failed. Action: Use MAP0210 General problem resolution. |
| 923-701 | 923
821 |
Error configuring the device. Action: Use MAP0210 General problem resolution. |
| 923-901 | 821 | The error log indicates an adapter failed. Action: Use MAP0210 General problem resolution. |
| 923-902 | 923
821 |
The error log analysis indicates a device failure. Action: Use MAP0210 General problem resolution. |
| 923-903 | 923
821 |
The error log analysis indicates an unknown failure. Action: Use MAP0210 General problem resolution. |
| 925-111 | 925
823 |
An unexpected device error occurred. Action: Use MAP0210 General problem resolution. |
| 925-112 | 925
823 |
The device disable test failed. Action: Use MAP0210 General problem resolution. |
| 925-113 | 925 | Could not reset the device. Action: Use MAP0210 General problem resolution. |
| 925-114 | 925
823 |
The Read Status command failed. Action: Use MAP0210 General problem resolution. |
| 925-115 | 925 | The device test failed. Action: Use MAP0210 General problem resolution. |
| 925-116 | 925 | Unknown Mouse type. Action: Use MAP0210 General problem resolution. |
| 925-117 | 925
823 |
Mouse wrap mode failed. Action: Use MAP0210 General problem resolution. |
| 925-118 | 925
823 |
Error setting mouse parameters. Action: Use MAP0210 General problem resolution. |
| 925-121
to 925-171 |
925 | The device test failed. Action: Use MAP0210 General problem resolution. |
| 925-200 | 925
823 |
A software error was caused by a hardware failure. Action: Use MAP0210 General problem resolution. |
| 925-300 | 925 | The error log analysis indicates a hardware failure. Action: Use MAP0210 General problem resolution. |
| 925-301 | 925
823 |
The error log analysis indicates a hardware failure. Action: Use MAP0210 General problem resolution. |
| 926-104 | 926
159 |
Input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 926-111 | 824 | Adapter error. Action: Use MAP0210 General problem resolution. |
| 926-112
to 926-115 |
926
824 |
Device, adapter or tablet reset failed. Action: Use MAP0210 General problem resolution. |
| 926-116 | 159 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 926-119 | 188 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 926-121 | 824 | Adapter error. Action: Use MAP0210 General problem resolution. |
| 926-131 | 824
926 |
Adapter error. Action: Use MAP0210 General problem resolution. |
| 926-132
to 926-135 |
926 | Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 926-141 | 824
926 |
Adapter error. Action: Use MAP0210 General problem resolution. |
| 926-142
to 926-161 |
926 | Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 926-162 | 159
926 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 926-163 | 159
926 |
Error in turning off input device LED. Action: Use MAP0210 General problem resolution. |
| 926-164 | 159
926 |
Error in turning off input device LED. Action: Use MAP0210 General problem resolution. |
| 926-165 | 159 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 926-166 | 188
926 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 926-167 | 188
926 |
Error in turning off input device LED. Action: Use MAP0210 General problem resolution. |
| 926-168 | 188
926 |
Error in turning on input device LED. Action: Use MAP0210 General problem resolution. |
| 926-169 | 188 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 926-172 | 159
926 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 926-173 | 159
926 |
Error in turning off input device switch. Action: Use MAP0210 General problem resolution. |
| 926-174 | 159
926 |
Error in turning on input device switch. Action: Use MAP0210 General problem resolution. |
| 926-175 | 159 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 926-176 | 188
926 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 926-177 | 188
926 |
Error in turning off input device switch. Action: Use MAP0210 General problem resolution. |
| 926-178 | 188
926 |
Error in turning on input device switch. Action: Use MAP0210 General problem resolution. |
| 926-179 | 188 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 926-181 | 824
926 |
Adapter error. Action: Use MAP0210 General problem resolution. |
| 926-182 | 159
926 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 926-183 | 159
926 |
Error in incremental data mode test. Action: Use MAP0210 General problem resolution. |
| 926-184 | 159 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 926-186 | 188
926 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 926-187 | 188
926 |
The incremental data mode test failed. Action: Use MAP0210 General problem resolution. |
| 926-188 | 188 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 926-203 | 926
824 |
Error in disabling tablet. Action: Use MAP0210 General problem resolution. |
| 926-204 | 926
824 |
Error in enabling tablet. Action: Use MAP0210 General problem resolution. |
| 926-207 | 926
824 |
Enabled/disabled test failed. Action: Use MAP0210 General problem resolution. |
| 926-208 | 926
824 |
Enabled/disabled test failed. Action: Use MAP0210 General problem resolution. |
| 926-221 | 824 | Adapter error. Action: Use MAP0210 General problem resolution. |
| 926-222 | 926
824 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 926-225 | 159 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 926-229 | 188 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 926-271 | 926 | Adapter error. Action: Use MAP0210 General problem resolution. |
| 926-272 | 159
926 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 926-273 | 159 | Error in input device switch test. Action: Use MAP0210 General problem resolution. |
| 926-274 | 159 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 926-276 | 188
926 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 926-277 | 188
926 |
Error in input device switch test. Action: Use MAP0210 General problem resolution. |
| 926-278 | 188 | Input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 926-281 | 824
926 |
Adapter error. Action: Use MAP0210 General problem resolution. |
| 926-282 | 159
926 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 926-283 | 159
926 |
Error in incremental data mode test. Action: Use MAP0210 General problem resolution. |
| 926-284 | 159 | The input device cable is not attached. |
| 926-286 | 188
926 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 926-287 | 188
926 |
Error in incremental data mode test. Action: Use MAP0210 General problem resolution. |
| 926-288 | 188 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 927-104 | 927
159 |
The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 927-111 | 824 | Adapter error. Action: Use MAP0210 General problem resolution. |
| 927-112 | 927
824 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 927-113 | 927
824 |
Tablet reset failed. Action: Use MAP0210 General problem resolution. |
| 927-114 | 927
824 |
The read configuration test failed. Action: Use MAP0210 General problem resolution. |
| 927-115 | 927
824 |
The read status test failed. Action: Use MAP0210 General problem resolution. |
| 927-116 | 159 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 927-119 | 188 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 927-121 | 824 | Adapter error. Action: Use MAP0210 General problem resolution. |
| 927-122 | 927
824 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 927-125 | 927
824 |
The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 927-131 | 824
927 |
Adapter error. Action: Use MAP0210 General problem resolution. |
| 927-132 | 927 | Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 927-133 | 927 | The set conversion mode test failed. Action: Use MAP0210 General problem resolution. |
| 927-134 | 927 | The set resolution test failed. Action: Use MAP0210 General problem resolution. |
| 927-135 | 927 | The read status test failed. Action: Use MAP0210 General problem resolution. |
| 927-141 | 824
927 |
Adapter error. Action: Use MAP0210 General problem resolution. |
| 927-142 | 927 | Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 927-143 | 927 | Error in tablet indicator. Action: Use MAP0210 General problem resolution. |
| 927-161 | 927 | Adapter error. Action: Use MAP0210 General problem resolution. |
| 927-162 | 159
927 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 927-163 | 159
927 |
Error in turning off input device LED. Action: Use MAP0210 General problem resolution. |
| 927-164 | 159
927 |
Error in turning on input device LED. Action: Use MAP0210 General problem resolution. |
| 927-165 | 159 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 927-166 | 188
927 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 927-167 | 188
927 |
Error in turning off input device LED. Action: Use MAP0210 General problem resolution. |
| 927-168 | 188
927 |
Error in turning on input device LED. Action: Use MAP0210 General problem resolution. |
| 927-169 | 188 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 927-171 | 927 | Adapter error. Action: Use MAP0210 General problem resolution. |
| 927-172 | 159
927 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 927-173 | 159
927 |
Error in turning off input device switch. Action: Use MAP0210 General problem resolution. |
| 927-174 | 159
927 |
Error in turning on input device switch. Action: Use MAP0210 General problem resolution. |
| 927-175 | 159 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 927-176 | 188
927 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 927-177 | 188
927 |
Error in turning off input device switch. Action: Use MAP0210 General problem resolution. |
| 927-178 | 188
927 |
Error in turning on input device switch. Action: Use MAP0210 General problem resolution. |
| 927-179 | 188 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 927-181 | 824
927 |
Adapter error. Action: Use MAP0210 General problem resolution. |
| 927-182 | 159
927 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 927-183 | 159
927 |
Error in incremental data mode test. Action: Use MAP0210 General problem resolution. |
| 927-184 | 159 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 927-186 | 188
927 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 927-187 | 188
927 |
Error in incremental data mode test. Action: Use MAP0210 General problem resolution. |
| 927-188 | 188 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 927-203 | 927
824 |
Error in disabling tablet. Action: Use MAP0210 General problem resolution. |
| 927-204 | 927
824 |
Error in enabling tablet. Action: Use MAP0210 General problem resolution. |
| 927-221 | 824 | Adapter error. Action: Use MAP0210 General problem resolution. |
| 927-222 | 927
824 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 927-225 | 159 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 927-229 | 188 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 927-271 | 927 | Adapter error. Action: Use MAP0210 General problem resolution. |
| 927-272 | 159
927 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 927-273 | 159
927 |
Error in input device switch test. Action: Use MAP0210 General problem resolution. |
| 927-274 | 159 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 927-276 | 188
927 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 927-277 | 188
927 |
Error in input device switch test. Action: Use MAP0210 General problem resolution. |
| 927-278 | 188 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 927-281 | 824
927 |
Adapter error. Action: Use MAP0210 General problem resolution. |
| 927-282 | 159
927 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 927-283 | 159
927 |
Error in incremental data mode test. Action: Use MAP0210 General problem resolution. |
| 927-284 | 159 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 927-286 | 188
927 |
Device or adapter error. Action: Use MAP0210 General problem resolution. |
| 927-287 | 188
927 |
Error in incremental data mode test. Action: Use MAP0210 General problem resolution. |
| 927-288 | 188 | The input device cable is not attached. Action: Use MAP0210 General problem resolution. |
| 929-201 | 929 | Failed to register input ring. Action: Use MAP0210 General problem resolution. |
| 929-202 | 929 | Unable to read event from the device. Action: Use MAP0210 General problem resolution. |
| 929-203 | 929 | Unable to communicate with the device. Action: Use MAP0210 General problem resolution. |
| 929-204 | 929 | Cannot set the device granularity. Action: Use MAP0210 General problem resolution. |
| 929-210 | 929 | Device or adapter failure. Action: Use MAP0210 General problem resolution. |
| 929-212 | 929 | Cannot set the device to HIGH granularity. Action: Use MAP0210 General problem resolution. |
| 929-213 | 929 | Cannot set the device to LOW granularity. Action: Use MAP0210 General problem resolution. |
| 929-299 | software
929 |
Error unconfiguring the device. Action: Use MAP0210 General problem resolution. |
| 929-301 | software
929 |
Error configuring the device. Action: Use MAP0210 General problem resolution. |
| 930-201 | 930 | Device or adapter failure. Action: Use MAP0210 General problem resolution. |
| 930-210 | 930 | Unable to turn the lights on. Action: Use MAP0210 General problem resolution. |
| 930-220 | 930 | Unable to turn the lights off hardware failure. Action: Use MAP0210 General problem resolution. |
| 930-230 | 930 | Unable to turn the lights off. Action: Use MAP0210 General problem resolution. |
| 930-241 | 930 | Unable to turn a single light-on. Action: Use MAP0210 General problem resolution. |
| 930-242 | 930 | Device or adapter failure. Action: Use MAP0210 General problem resolution. |
| 930-243 | 930 | Device or adapter failure. Action: Use MAP0210 General problem resolution. |
| 930-261 | 930 | Cable test failed. Action: Use MAP0210 General problem resolution. |
| 930-262 | 930 | Cable test failed. Action: Use MAP0210 General problem resolution. |
| 930-299 | software
930 |
Error unconfiguring the device. Action: Use MAP0210 General problem resolution. |
| 930-301 | software
930 |
Error configuring the device. Action: Use MAP0210 General problem resolution. |
| 935-101
to 935-102 |
935
828 |
The diskette-drive select or deselect test failed. Action: Use MAP0210 General problem resolution. |
| 935-103
to 935-107 |
935
828 |
The diskette failed. Action: Use MAP0210 General problem resolution. |
| 935-108 | 935 | The diskette read test failed. Action: Use MAP0210 General problem resolution. |
| 935-109
to 935-110 |
935
828 |
The read/write on the diskette drive failed. Action: Use MAP0210 General problem resolution. |
| 935-111
to 935-114 |
935 | A diskette drive test failed. Action: Use MAP0210 General problem resolution. |
| 935-115
to 935-121 |
935
828 |
The diskette drive test failed. Action: Use MAP0210 General problem resolution. |
| 935-122 | 935
828 |
The error log analysis indicates a hardware failure. Action: Use MAP0210 General problem resolution. |
| 935-123 | 935 | The error log analysis indicates a hardware failure. Action: Use MAP0210 General problem resolution. |
| 935-124 | 935
software |
Unable to configure the device. Action: Use MAP0210 General problem resolution. |
| 938-101 | 938
227 |
HIPPI Adapter test failed. Action: Use MAP0210 General problem resolution. |
| 938-104 | 938
227 |
HIPPI Adapter test failed. Action: Use MAP0210 General problem resolution. |
| 938-105 | 938
227 |
HIPPI Adapter test failed. Action: Use MAP0210 General problem resolution. |
| 938-108 | 938
227 |
HIPPI Adapter test failed. Action: Use MAP0210 General problem resolution. |
| 938-109 | 938
227 |
HIPPI Adapter test failed. Action: Use MAP0210 General problem resolution. |
| 938-10A | 938
227 |
HIPPI Adapter test failed. Action: Use MAP0210 General problem resolution. |
| 938-10B | 938
227 |
HIPPI Adapter test failed. Action: Use MAP0210 General problem resolution. |
| 938-10C | Wrap-
Plug 938 |
HIPPI Adapter test failed. Action: Use MAP0210 General problem resolution. |
| 938-124 | 938
227 |
HIPPI Adapter test failed. Action: Use MAP0210 General problem resolution. |
| 938-600 | 938
227 software |
HIPPI Adapter test failed. Action: Use MAP0210 General problem resolution. |
| 938-800 | 938
227 |
HIPPI Adapter test failed. Action: Use MAP0210 General problem resolution. |
| 945-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 946-111 | 946
227 |
Cannot run the test because the device driver detected a hardware error. Action: Use MAP0210 General problem resolution. |
| 946-114 | 946 | The register verification test failed. Action: Use MAP0210 General problem resolution. |
| 946-121 | 946
227 |
Cannot run the test because the device driver detected a hardware error. Action: Use MAP0210 General problem resolution. |
| 946-122 | 946
227 |
The data wrap communications test failed. Action: Use MAP0210 General problem resolution. |
| 946-123 | 946
227 |
The modem control line test failed. Action: Use MAP0210 General problem resolution. |
| 946-131 | 946 | Cannot run the test because the device driver detected a hardware error. Action: Use MAP0210 General problem resolution. |
| 946-132 | 946
227 |
The data wrap communications test failed. Action: Use MAP0210 General problem resolution. |
| 946-133 | 946 | The modem control line test failed. Action: Use MAP0210 General problem resolution. |
| 946-161 | 252 | Could not do the test because the device driver detected a hardware error. Action: Use MAP0210 General problem resolution. |
| 946-162 | 252 | The data wrap communication test failed. Action: Use MAP0210 General problem resolution. |
| 946-163 | 252 | The modem control line test failed. Action: Use MAP0210 General problem resolution. |
| 946-171 | 259 | Cannot run the test because the device driver detected a hardware error. Action: Use MAP0210 General problem resolution. |
| 946-172 | 259 | The data wrap communications test failed. Action: Use MAP0210 General problem resolution. |
| 946-173 | 259 | The modem control line test failed. Action: Use MAP0210 General problem resolution. |
| 946-181 | 261 | Cannot run the test because the device driver detected a hardware error. Action: Use MAP0210 General problem resolution. |
| 946-182 | 261 | The data wrap communications test failed. Action: Use MAP0210 General problem resolution. |
| 946-183 | 261 | The modem control line test failed. Action: Use MAP0210 General problem resolution. |
| 946-271 | 946
259 |
Cannot run the test because the device driver detected a hardware error. Action: Use MAP0210 General problem resolution. |
| 946-272 | 946
259 |
The data wrap communication test failed. Action: Use MAP0210 General problem resolution. |
| 946-273 | 946
259 |
The modem control line test failed. Action: Use MAP0210 General problem resolution. |
| 946-281 | 946
261 |
Cannot run the test because the device driver detected a hardware error. Action: Use MAP0210 General problem resolution. |
| 946-282 | 946
261 |
The data wrap communications test failed. Action: Use MAP0210 General problem resolution. |
| 946-283 | 946
261 |
The modem control line test failed. Action: Use MAP0210 General problem resolution. |
| 946-321 | 946 | Cannot run the test because the device driver detected a hardware error. Action: Use MAP0210 General problem resolution. |
| 946-322 | 946 | The data wrap communications test failed. Action: Use MAP0210 General problem resolution. |
| 946-323 | 946 | The modem control line test failed. Action: Use MAP0210 General problem resolution. |
| 946-331 | 946 | Cannot run the test because the device driver detected a hardware error. Action: Use MAP0210 General problem resolution. |
| 946-332 | 946 | The data wrap communications test failed. Action: Use MAP0210 General problem resolution. |
| 946-333 | 946 | The modem control line test failed. Action: Use MAP0210 General problem resolution. |
| 946-371 | 946 | Cannot run the test because the device driver detected a hardware error. Action: Use MAP0210 General problem resolution. |
| 946-372 | 946 | The data wrap communications test failed. Action: Use MAP0210 General problem resolution. |
| 946-373 | 946 | The modem control line test failed. Action: Use MAP0210 General problem resolution. |
| 946-381 | 946 | Cannot run the test because the device driver detected a hardware error. Action: Use MAP0210 General problem resolution. |
| 946-382 | 946 | The data wrap communications test failed. Action: Use MAP0210 General problem resolution. |
| 946-383 | 946 | The modem control line test failed. Action: Use MAP0210 General problem resolution. |
| 946-481 | D56 | Could not do the test because the device driver detected a hardware error. Action: Use MAP0210 General problem resolution. |
| 946-482 | D56 | The data wrap communication test failed. Action: Use MAP0210 General problem resolution. |
| 946-483 | D56 | The modem control line test failed. Action: Use MAP0210 General problem resolution. |
| 946-581 | 946
D56 |
Could not do the test because the device driver detected a hardware error. Action: Use MAP0210 General problem resolution. |
| 946-582 | 946
D56 |
The data wrap communication test failed. Action: Use MAP0210 General problem resolution. |
| 946-583 | 946
D56 |
The modem control line test failed. Action: Use MAP0210 General problem resolution. |
| 946-901
to 946-920 |
software
946 |
An unexpected error occurred that can be attributed to software or hardware. Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use MAP0210 General problem resolution with a FFC of 946; otherwise, suspect a software problem. |
| 946-921 | 946
software |
The adapter failed to configure. Action: Use MAP0210 General problem resolution. |
| 946-922
to 946-924 |
software
946 |
An unexpected error occurred that can be attributed to software or hardware. Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use MAP0210 General problem resolution with a FFC of 946; otherwise, suspect a software problem. |
| 946-925 | 946
software |
The adapter failed to configure. Action: Use MAP0210 General problem resolution. |
| 946-926
to 946-943 |
software
946 |
An unexpected error occurred that can be attributed to software or hardware. Action: Run diagnostics from a source other than from the disk or a network. If the same error occurs or if the original SRN was not obtained from disk or a network based diagnostics, use MAP0210 General problem resolution with a FFC of 946; otherwise, suspect a software problem. |
| 947-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 950-100 | 192 | Power supply problem. Action: Use the service documentation for the portable disk. |
| 950-101 | 2C9
153 |
PCI bus was not found. Action: Rerun diagnostics in Advanced Mode for additional problem isolation. |
| 950-102 | 2C9 | PCI bus was not found. Action: UseMAP0291 Missing device or bus problem resolution. |
| 950-103 | 2C9 | Multiple adapters on bus were not found. Action: Use MAP0210 General problem resolution. |
| 950-105 | 2C9
221 |
PCI bus was not found. Action: UseMAP0291 Missing device or bus problem resolution. |
| 950-106 | 2C9 | PCI bus was not found. Action: UseMAP0291 Missing device or bus problem resolution. |
| 950-107 | 153
165 |
The device is not responding. Action: UseMAP0291 Missing device or bus problem resolution. |
| 950-108 | 190
199 153 165 |
The device is not responding. Action: UseMAP0291 Missing device or bus problem resolution. |
| 950-200 | 152 | Power supply problem. Action: Use the service documentation for the external device. |
| 950-201 | SCSI Bus | SCSI bus problem. Action: Refer to MAP2010 RPC card causes false fence. |
| 950-400 | 153 | Power supply problem. Action: Use the service documentation for the drawer/tower containing the failing power supply. If the drawer/deskside unit service documentation does not isolate the problem, go to MAP 1520: Power. |
| 950-440 | 440
B88 190 199 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution. |
| 950-441 | 440
B88 190 199 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution. |
| 950-442 | 440
B88 190 199 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution. |
| 950-443 | 440
B88 190 199 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution. |
| 950-451 | 451
B88 190 199 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution. |
| 950-500 | 152 | Power supply problem. Action: Use the service documentation for the system unit, rack, or drawer that contains the missing device. |
| 950-56D | 58D
B88 190 152 |
The device is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-58D | 58D
B88 190 152 |
The device is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-61D | 61D
B88 190 152 |
The device is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-638 | 638
B88 277 190 152 |
The SCSI device is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-639 | 639
B88 190 152 |
The device is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-63A | 63A
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-63B | 63B
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-63C | 63C
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-63D | 63D
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-63E | 63E
B88 277 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-63F | 63F
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-640 | 640
B88 190 152 |
The device is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-664 | 664
B88 190 152 |
The device is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-678 | 678
B88 190 152 |
The SCSI Tape Drive is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-679 | 679
B88 190 152 |
The SCSI Disk Drive is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-681 | 681
2E7 190 152 |
The SCSI Disk Drive is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-700 | 700
B88 190 152 |
The device is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-701 | 701
B88 190 152 |
The device is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-702 | 702
B88 190 152 |
The device is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-703 | 703
B88 190 152 |
The device is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-704 | 704
B88 190 152 |
The device is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-705 | 705
B88 190 152 |
The device is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-706 | 706
B88 190 152 |
The device is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-707 | 707
B88 190 152 |
The device is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-721 | 721
B88 190 152 |
An unknown drive type is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-722 | 722
B88 190 152 |
The device is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-723 | 723
B88 190 152 |
The device is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-724 | 724
B88 190 152 |
The device is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-734 | 734
B88 190 152 |
The device is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-741 | 741
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-772 | 772
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-773 | 773
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-789 | 789
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-792 | 792
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-793 | 793
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-804 | 807
B88 190 152 |
The device is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-807 | 804
B88 190 152 |
The device is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-912 | 912
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-914 | 914
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-915 | 915
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-917 | 917
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-918 | 918
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-935 | 935
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-951 | 951
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-952 | 952
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-953 | 953
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-954 | 954
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-955 | 955
B88 190 141 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-956 | 956
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-959 | 959
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-960 | 960
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-964 | 964
B88 190 152 |
The SCSI Tape Drive is not responding. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-968 | 968
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-970 | 970
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-971 | 971
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-972 | 972
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-974 | 974
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-981 | 981
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-984 | 984
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-986 | 986
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-987 | 987
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-989 | 989
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-990 | 990
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-991 | 991
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-994 | 994
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-995 | 995
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-998 | 998
B88 190 152 |
Device does not respond. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-2522 | 2522
221 |
Missing options resolution for PCI-x Dual Channel Ultra320 SCSI Adapter. Action: UseMAP0291 Missing device or bus problem resolution. |
| 950-2523 | 2523
221 |
Missing options resolution for PCI-X Dual Channel Ultra320 SCSI Adapter. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-2524 | 2524
|
Missing options resolution for PCI-X Dual Channel Ultra320 SCSI Adapter. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-2525 | 2525
2524 |
Missing options resolution for PCI-X Dual Channel Ultra320 SCSI Adapter. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-2527 | 2527
221 |
Missing options resolution for PCI-X Dual Channel Ultra320 SCSI Adapter. Action: UseMAP0291 Missing device or bus problem resolution |
| 950-xxxx
|
xxxx
B88 190 152 |
The device does not respond. Action: UseMAP0291 Missing device or bus problem resolution Note: xxxx corresponds
to the last three or four digits of the SRN after the dash (-). If your 950-xxxx SRN
is not listed, substitute the last three or four digits of the SRN for xxxx.
|
| 951-xxx
to 957-xxx |
See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 959-102 | 959 | Non-recoverable medium error. Action: Use MAP0210 General problem resolution. |
| 959-104 | 959 | Motor failed to restart. Action: Use MAP0210 General problem resolution. |
| 959-105 | 959 | The drive did not become ready. Action: Use MAP0210 General problem resolution. |
| 959-106 | 959 | Electronics card failure. Action: Use MAP0210 General problem resolution. |
| 959-108 | 959 | Bus failure. Action: Use MAP0210 General problem resolution. |
| 959-110 | 959 | The media format is corrupted. Action: Use MAP0210 General problem resolution. |
| 959-112 | 959 | Diagnostic failure. Action: Use MAP0210 General problem resolution. |
| 959-114 | 959 | Non-recoverable hardware error. Action: Use MAP0210 General problem resolution. |
| 959-116 | A protocol error was detected. Action: Check the levels of the device, adapter, diagnostic and application software, and ensure they are all compatible. If you do not find a problem, call your support person. | |
| 959-117 | 959 | Write-protect error. Action: Use MAP0210 General problem resolution. |
| 959-118 | 959
B88 |
SCSI command timeout. Action: Use MAP0210 General problem resolution. |
| 959-120 | 959 | SCSI busy/command error. Action: Use MAP0210 General problem resolution. |
| 959-122 | 959 | SCSI reservation conflict error. Action: Use MAP0210 General problem resolution. |
| 959-124 | 959 | SCSI check condition error. Action: Use MAP0210 General problem resolution. |
| 959-126 | 959
B88 |
Software error caused by hardware failure. Action: Use MAP0210 General problem resolution. |
| 959-128 | 959 | Error log analysis indicates hardware failure. Action: Use MAP0210 General problem resolution. |
| 959-129 | 190
959 B88 software |
Error log analysis indicates a SCSI bus problem. Action: Use MAP0210 General problem resolution. |
| 959-130 | 959 | Error log analysis indicates a problem reported by the disk drive's self-monitoring function. Action: Use MAP0210 General problem resolution. |
| 959-134 | B88
software |
The adapter failed to configure. Action: Use MAP0210 General problem resolution. |
| 959-135 | 959
B88 software |
The device failed to configure. Action: Use MAP0210 General problem resolution. |
| 959-136 | 959 | The certify operation failed. Action: Use MAP0210 General problem resolution. |
| 959-137 | 959
B88 190 |
Unit attention condition has occurred on the Send Diagnostic command. Action: Use MAP0210 General problem resolution. |
| 960-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 964-101 | 964 | Timeout while attempting to communicate with SCSI device. Action: Use MAP0210 General problem resolution. |
| 964-102 | 964 | The SCSI device indicates busy. Action: Use MAP0210 General problem resolution. |
| 964-103 | 964 | The SCSI device indicates a reservation conflict. Action: Use MAP0210 General problem resolution. |
| 964-104 | 964 | The SCSI device indicates a check condition. Action: Use MAP0210 General problem resolution. |
| 964-105 | 964 | An error is detected in request sense data. Action: Use MAP0210 General problem resolution. |
| 964-107 | 964 | Sense data from the SCSI drive has unexpected data. Action: Use MAP0210 General problem resolution. |
| 964-110 | 964 | The Reserve command failed. Action: Use MAP0210 General problem resolution. |
| 964-111 | 964 | Invalid condition from the drive after a reserve. Action: Use MAP0210 General problem resolution. |
| 964-112 | 964 | The write-protect sensor test failed. Action: Use MAP0210 General problem resolution. |
| 964-113 | 964 | Invalid condition from drive after a request sense. Action: Use MAP0210 General problem resolution. |
| 964-114 | 964 | Timeout while attempting to communicate with the SCSI device. Action: Use MAP0210 General problem resolution. |
| 964-120 | 964 | The Inquiry command failed. Action: Use MAP0210 General problem resolution. |
| 964-130 | 964
media |
The Load command failed. Action: Use MAP0210 General problem resolution. |
| 964-134 | B88
software |
The adapter failed to configure. Action: Use MAP0210 General problem resolution. |
| 964-135 | 964
media |
The Unload command failed. Action: Use MAP0210 General problem resolution. |
| 964-140 | 964 | The Mode Select command failed. Action: Use MAP0210 General problem resolution. |
| 964-150 | 964
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution. |
| 964-160 | 964
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution. |
| 964-161 | 964
B88 |
Invalid condition from the drive after a reserve. Action: Use MAP0210 General problem resolution. |
| 964-163 | 964
B88 |
Invalid condition from the drive after a request sense. Action: Use MAP0210 General problem resolution. |
| 964-164 | 964
B88 |
Timeout while attempting to communicate with the SCSI device. Action: Use MAP0210 General problem resolution. |
| 964-165 | 964
B88 276 |
Write, Read and Compare Test failed. Action: Use MAP0210 General problem resolution. |
| 964-166 | 964
B88 software |
Unable to configure the device. Action: Use MAP0210 General problem resolution. |
| 964-167 | 964
B88 |
An unexpected SCSI error occurred. Action: Use MAP0210 General problem resolution. |
| 964-168 | B88
software |
The adapter failed to configure. Action: Use MAP0210 General problem resolution. |
| 964-169 | 964
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution. |
| 964-170 | 964
B88 media |
The Read, Write and Compare test failed. Action: Use MAP0210 General problem resolution. |
| 964-180 | 964
media |
The Load command failed. Action: Use MAP0210 General problem resolution. |
| 964-185 | 964
media |
The Unload command failed. Action: Use MAP0210 General problem resolution. |
| 964-190 | 964 | The Mode Select command failed. Action: Use MAP0210 General problem resolution. |
| 964-200 | 964
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution. |
| 964-201 | 964
B88 |
Error diagnosed from error log analysis. Action: Use MAP0210 General problem resolution. |
| 964-210 | 964
B88 |
The device configuration failed. Action: Use MAP0210 General problem resolution. |
| 964-211 | 964
B88 |
The device open failed. Action: Use MAP0210 General problem resolution. |
| 964-220 | 964 | The Release command failed. Action: Use MAP0210 General problem resolution. |
| 964-230 | 964 | The Request Sense command failed. Action: Use MAP0210 General problem resolution. |
| 964-240 | 964 | The Openx command failed. Action: Use MAP0210 General problem resolution. |
| 964-260 | 964 | The device configuration failed. Action: Use MAP0210 General problem resolution. |
| 964-261 | 964 | The device open failed. Action: Use MAP0210 General problem resolution. |
| 964-300 | 964
software |
The device configuration failed. Action: Use MAP0210 General problem resolution. |
| 964-310 | B88
964 software |
SCSI adapter configuration failed. Action: Use MAP0210 General problem resolution. |
| 964-320 | 964
media |
Error log analysis indicates a failure. Action: Use MAP0210 General problem resolution. |
| 964-411
to 964-423 |
964
B88 software |
A reservation conflict occurred. Action: Use MAP0210 General problem resolution. |
| 964-511
to 964-523 |
964
B88 |
The drive returned bad or non-extended sense data. Action: Use MAP0210 General problem resolution. |
| 964-611 to 964-623 | 964
B88 software |
An adapter or bus I/O error occurred. Action: Use MAP0210 General problem resolution. |
| 964-711 to 964-723 | 964
B88 software |
A device timeout error occurred. Action: Use MAP0210 General problem resolution. |
| 966-101 | 966 | Error in non-interactive tests. Action: Use MAP0210 General problem resolution. |
| 966-103 | 966 | The test pattern failed. Action: Use MAP0210 General problem resolution. |
| 966-201 | 966
190 |
Error in non-interactive tests on card. Action: Use MAP0210 General problem resolution. |
| 966-203 | 966
190 |
The test pattern failed. Action: Use MAP0210 General problem resolution. |
| 966-205 | 966
190 |
Test pattern failed. Action: Use MAP0210 General problem resolution. |
| 966-207 | 966
190 |
Test pattern failed. Action: Use MAP0210 General problem resolution. |
| 966-208 | 190 | Error in non-interactive test on card. Action: Use MAP0210 General problem resolution. |
| 966-209 | 190 | Test pattern failed. Action: Use MAP0210 General problem resolution. |
| 966-211 | 190 | Test pattern failed. Action: Use MAP0210 General problem resolution. |
| 966-213 | 190 | Test pattern failed. Action: Use MAP0210 General problem resolution. |
| 966-304 | E22
725 966 |
Video error in interactive test. Action: Use MAP0210 General problem resolution. |
| 966-306 | E23
725 966 |
Audio error in interactive test. Action: Use MAP0210 General problem resolution. |
| 966-310 | E22
725 |
Video error in interactive test. Action: Use MAP0210 General problem resolution. |
| 966-312 | E22
725 |
Audio error in interactive test. Action: Use MAP0210 General problem resolution. |
| 966-400 | 152
190 E24 166 |
Error in non-interactive tests. Action: Use MAP0210 General problem resolution. |
| 966-402 | 190
E23 E22 |
Test pattern failed. Action: Use MAP0210 General problem resolution. |
| 968-xxx | See SCSI devices SRNs ssss-102 through ssss-640. | |
| 970-098 | 970 | Tape drive indicates an error. |
| 970-099 | 970
B88 |
Tape drive not found. |
| 970-101 | 970 | Timeout while attempting to communicate with SCSI device. Action: Use MAP0210 General problem resolution. |
| 970-102 | 970 | The SCSI device indicates busy. Action: Use MAP0210 General problem resolution. |
| 970-103 | 970 | The SCSI device indicates a reservation conflict. Action: Use MAP0210 General problem resolution. |
| 970-104 | 970 | The SCSI device indicates a check condition. Action: Use MAP0210 General problem resolution. |
| 970-105 | 970 | An error is detected in request sense data. Action: Use MAP0210 General problem resolution. |
| 970-107 | 970 | Sense data from the SCSI drive has unexpected data. Action: Use MAP0210 General problem resolution. |
| 970-110 | 970 | The Reserve command failed. Action: Use MAP0210 General problem resolution. |
| 970-111 | 970 | Invalid condition from the drive after a reserve. Action: Use MAP0210 General problem resolution. |
| 970-112 | 970 | The write-protect sensor test failed. Action: Use MAP0210 General problem resolution. |
| 970-113 | 970 | Invalid condition from drive after a request sense. Action: Use MAP0210 General problem resolution. |
| 970-114 | 970 | Timeout while attempting to communicate with the SCSI device. Action: Use MAP0210 General problem resolution. |
| 970-120 | 970 | The Inquiry command failed. Action: Use MAP0210 General problem resolution. |
| 970-130 | 970
media |
The Load command failed. Action: Use MAP0210 General problem resolution. |
| 970-134 | B88
software |
The adapter failed to configure. Action: Use MAP0210 General problem resolution. |
| 970-135 | 970
media |
The Unload command failed. Action: Use MAP0210 General problem resolution. |
| 970-140 | 970 | The Mode Select command failed. Action: Use MAP0210 General problem resolution. |
| 970-150 | 970
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution. |
| 970-160 | 970
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution. |
| 970-161 | 970
B88 |
Invalid condition from the drive after a reserve. Action: Use MAP0210 General problem resolution. |
| 970-163 | 970
B88 |
Invalid condition from the drive after a request sense. Action: Use MAP0210 General problem resolution. |
| 970-164 | 970
B88 |
Timeout while attempting to communicate with the SCSI device. Action: Use MAP0210 General problem resolution. |
| 970-165 | 970
B88 276 |
Write, Read and Compare Test failed. Action: Use MAP0210 General problem resolution. |
| 970-166 | 970
B88 software |
Unable to configure the device. Action: Use MAP0210 General problem resolution. |
| 970-167 | 970
B88 |
An unexpected SCSI error occurred. Action: Use MAP0210 General problem resolution. |
| 970-168 | B88
software |
The adapter failed to configure. Action: Use MAP0210 General problem resolution. |
| 970-169 | 970
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution. |
| 970-170 | 970
B88 media |
The Read, Write and Compare test failed. Action: Use MAP0210 General problem resolution. |
| 970-180 | 970
media |
The Load command failed. Action: Use MAP0210 General problem resolution. |
| 970-185 | 970
media |
The Unload command failed. Action: Use MAP0210 General problem resolution. |
| 970-190 | 970 | The Mode Select command failed. Action: Use MAP0210 General problem resolution. |
| 970-200 | 970
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution. |
| 970-201 | 970
B88 |
Error diagnosed from error log analysis. Action: Use MAP0210 General problem resolution. |
| 970-210 | 970
B88 |
The device configuration failed. Action: Use MAP0210 General problem resolution. |
| 970-211 | 970
B88 |
The device open failed. Action: Use MAP0210 General problem resolution. |
| 970-220 | 970 | The Release command failed. Action: Use MAP0210 General problem resolution. |
| 970-230 | 970 | The Request Sense command failed. Action: Use MAP0210 General problem resolution. |
| 970-240 | 970 | The Openx command failed. Action: Use MAP0210 General problem resolution. |
| 970-260 | 970 | The device configuration failed. Action: Use MAP0210 General problem resolution. |
| 970-261 | 970 | The device open failed. Action: Use MAP0210 General problem resolution. |
| 970-300 | 970
software |
The device configuration failed. Action: Use MAP0210 General problem resolution. |
| 970-310 | B88
970 software |
SCSI adapter configuration failed. Action: Use MAP0210 General problem resolution. |
| 970-320 | 970
media |
Error log analysis indicates a failure. Action: Use MAP0210 General problem resolution. |
| 970-411
to 970-423 |
970
B88 software |
A reservation conflict occurred. Action: Use MAP0210 General problem resolution. |
| 970-511
to 970-523 |
970
B88 |
The drive returned bad or non-extended sense data. Action: Use MAP0210 General problem resolution. |
| 970-57D | 57D | The resource does not respond. Action: Use MAP0210 General problem resolution. |
| 970-611
to 970-623 |
970
B88 software |
An adapter or bus I/O error occurred. Action: Use MAP0210 General problem resolution. |
| 970-711
to 970-723 |
970
B88 software |
A device timeout error occurred. Action: Use MAP0210 General problem resolution. |
| 971-101 | 971 | Timeout while attempting to communicate with SCSI device. Action: Use MAP0210 General problem resolution. |
| 971-102 | 971 | The SCSI device indicates busy. Action: Use MAP0210 General problem resolution. |
| 971-103 | 971 | The SCSI device is indicating a reservation conflict. Action: Use MAP0210 General problem resolution. |
| 971-104 | 971 | The SCSI device indicates a check condition. Action: Use MAP0210 General problem resolution. |
| 971-105 | 971 | Sense data from the SCSI device shows an error. Action: Use MAP0210 General problem resolution. |
| 971-107 | 971 | The SCSI drive returned unexpected sense data. Action: Use MAP0210 General problem resolution. |
| 971-110 | 971 | The Reserve command failed. Action: Use MAP0210 General problem resolution. |
| 971-111 | 971 | Invalid condition from the drive after a reserve. Action: Use MAP0210 General problem resolution. |
| 971-112 | 971 | The write-protect sensor test failed. Action: Use MAP0210 General problem resolution. |
| 971-113 | 971 | Invalid condition from the drive after a request sense. Action: Use MAP0210 General problem resolution. |
| 971-114 | 971 | Timeout while attempting to communicate with the SCSI device. Action: Use MAP0210 General problem resolution. |
| 971-120 | 971 | The Inquiry command failed. Action: Use MAP0210 General problem resolution. |
| 971-130 | 971
media |
The Load command failed. Action: Use MAP0210 General problem resolution. |
| 971-135 | 971
media |
The Unload command failed. Action: Use MAP0210 General problem resolution. |
| 971-140 | 971 | The Mode Select command failed. Action: Use MAP0210 General problem resolution. |
| 971-150 | 971
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution |
| 971-160 | 971
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution |
| 971-161 | 971
B88 |
Invalid condition from the drive after a reserve. Action: Use MAP0210 General problem resolution |
| 971-163 | 971
B88 |
Invalid condition from the drive after a request sense. Action: Use MAP0210 General problem resolution |
| 971-164 | 971
B88 |
Timeout while attempting to communicate with the SCSI device. Action: Use MAP0210 General problem resolution |
| 971-165 | 971
B88 276 |
Write, Read and Compare Test failed. Action: Use MAP0210 General problem resolution |
| 971-166 | 971
B88 software |
Unable to configure the device. Action: Use MAP0210 General problem resolution |
| 971-167 | 971
B88 |
An unexpected SCSI error occurred. Action: Use MAP0210 General problem resolution |
| 971-168 | B88
software |
The adapter failed to configure. Action: Use MAP0210 General problem resolution |
| 971-169 | 971
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution |
| 971-170 | 971
B88 media |
The Read, Write and Compare test failed. Action: Use MAP0210 General problem resolution |
| 971-180 | 971
media |
The Load command failed. Action: Use MAP0210 General problem resolution |
| 971-185 | 971
media |
The Unload command failed. Action: Use MAP0210 General problem resolution |
| 971-190 | 971 | The Mode Select command failed. Action: Use MAP0210 General problem resolution |
| 971-200 | 971
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution |
| 971-201 | 971
B88 |
An error is diagnosed from the error log analysis. Action: Use MAP0210 General problem resolution |
| 971-210 | 971
B88 |
The device configuration failed. Action: Use MAP0210 General problem resolution |
| 971-211 | 971
B88 |
The device open test failed. Action: Use MAP0210 General problem resolution |
| 971-220 | 971 | The Release command failed. Action: Use MAP0210 General problem resolution |
| 971-230 | 971 | The Request Sense command failed. Action: Use MAP0210 General problem resolution |
| 971-240 | 971 | The Openx command failed. Action: Use MAP0210 General problem resolution |
| 971-260 | 971 | The device configuration failed. Action: Use MAP0210 General problem resolution |
| 971-261 | 971 | The device open test failed. Action: Use MAP0210 General problem resolution |
| 971-300 | 971
software |
The device configuration failed. Action: Use MAP0210 General problem resolution |
| 971-310 | B88
971 software |
SCSI adapter configuration failed. Action: Use MAP0210 General problem resolution |
| 971-320 | 971
media |
Error log analysis indicates a failure. Action: Use MAP0210 General problem resolution |
| 971-411
to 971-423 |
971
B88 software |
A reservation conflict occurred. Action: Use MAP0210 General problem resolution |
| 971-511
to 971-523 |
971
B88 |
The drive returned bad or non-extended sense data. Action: Use MAP0210 General problem resolution |
| 971-611
to 971-623 |
971
software |
An adapter or bus I/O error occurred. Action: Use MAP0210 General problem resolution |
| 971-711
to 971-723 |
971
B88 software |
A device timeout error occurred. Action: Use MAP0210 General problem resolution |
| 972-101 | 972 | Timeout while attempting to communicate with SCSI device. Action: Use MAP0210 General problem resolution |
| 972-102 | 972 | The SCSI device indicates busy. Action: Use MAP0210 General problem resolution |
| 972-103 | 972 | The SCSI device indicates a reservation conflict. Action: Use MAP0210 General problem resolution |
| 972-104 | 972 | The SCSI device indicates a check condition. Action: Use MAP0210 General problem resolution |
| 972-105 | 972 | An error is detected in request sense data. Action: Use MAP0210 General problem resolution |
| 972-107 | 972 | The drive has returned unexpected sense data. Action: Use MAP0210 General problem resolution |
| 972-110 | 972 | The Reserve command failed. Action: Use MAP0210 General problem resolution |
| 972-111 | 972 | Invalid condition from the drive after a reserve. Action: Use MAP0210 General problem resolution |
| 972-112 | 972 | The write-protect sensor test failed. Action: Use MAP0210 General problem resolution |
| 972-113 | 972 | Invalid condition from the drive after a request sense. Action: Use MAP0210 General problem resolution |
| 972-114 | 972 | Timeout while attempting to communicate with the SCSI device. Action: Use MAP0210 General problem resolution |
| 972-120 | 972 | The Inquiry command failed. Action: Use MAP0210 General problem resolution |
| 972-130 | 972
media |
The Load command failed. Action: Use MAP0210 General problem resolution |
| 972-135 | 972
media |
The Unload command failed. Action: Use MAP0210 General problem resolution |
| 972-140 | 972 | The Mode Select command failed. Action: Use MAP0210 General problem resolution |
| 972-150 | 972
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution |
| 972-160 | 972
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution |
| 972-161 | 972
B88 |
Invalid condition from the drive after a reserve. Action: Use MAP0210 General problem resolution |
| 972-163 | 972
B88 |
Invalid condition from the drive after a request sense. Action: Use MAP0210 General problem resolution |
| 972-164 | 972
B88 276 |
Timeout while attempting communication with SCSI device. Action: Use MAP0210 General problem resolution |
| 972-165 | 972
B88 276 |
Write, Read and Compare Test failed. Action: Use MAP0210 General problem resolution |
| 972-166 | 972
B88 software |
Unable to configure the device. Action: Use MAP0210 General problem resolution |
| 972-167 | 972
B88 |
An unexpected SCSI error occurred. Action: Use MAP0210 General problem resolution |
| 972-168 | B88
software |
The adapter failed to configure. Action: Use MAP0210 General problem resolution |
| 972-169 | 972
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution |
| 972-170 | 972
B88 media |
The Read, Write and Compare test failed. Action: Use MAP0210 General problem resolution |
| 972-180 | 972
media |
The Load command failed. Action: Use MAP0210 General problem resolution |
| 972-185 | 972
media |
The Unload command failed. Action: Use MAP0210 General problem resolution |
| 972-190 | 972 | The Mode Select command failed. Action: Use MAP0210 General problem resolution |
| 972-200 | 972
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution |
| 972-201 | 972
B88 |
An error is diagnosed from the error log analysis. Action: Use MAP0210 General problem resolution |
| 972-210 | 972
B88 |
The device configuration failed. Action: Use MAP0210 General problem resolution |
| 972-211 | 972
B88 |
The device open test failed. Action: Use MAP0210 General problem resolution |
| 972-220 | 972 | The Release command failed. Action: Use MAP0210 General problem resolution |
| 972-230 | 972 | The Request Sense command failed. Action: Use MAP0210 General problem resolution |
| 972-240 | 972 | The Openx command failed. Action: Use MAP0210 General problem resolution |
| 972-260 | 972 | The device configuration test failed. Action: Use MAP0210 General problem resolution |
| 972-261 | 972 | The device open test failed. Action: Use MAP0210 General problem resolution |
| 972-300 | 972
software |
The device configuration failed. Action: Use MAP0210 General problem resolution |
| 972-310 | B88
972 software |
SCSI adapter configuration failed. Action: Use MAP0210 General problem resolution |
| 972-320 | 972
media |
Error log analysis indicates a failure. Action: Use MAP0210 General problem resolution |
| 972-411 to 972-423 | 972
B88 software |
A reservation conflict occurred. Action: Use MAP0210 General problem resolution |
| 972-511 to 972-523 | 972
B88 |
The drive returned bad or non-extended sense data. Action: Use MAP0210 General problem resolution |
| 972-611
to 972-623 |
972
B88 software |
An adapter or bus I/O error occurred. Action: Use MAP0210 General problem resolution |
| 972-711
to 972-723 |
972
B88 software |
A device timeout error occurred. Action: Use MAP0210 General problem resolution |
| 973-110 | 973 | The Reserve command failed. Action: Use MAP0210 General problem resolution |
| 973-120 | 973 | The Inquiry command failed. Action: Use MAP0210 General problem resolution |
| 973-130 | 973
media |
The Load command failed. Action: Use MAP0210 General problem resolution |
| 973-135 | 973
media |
The Unload command failed. Action: Use MAP0210 General problem resolution |
| 973-140 | 973 | The Mode Select command failed. Action: Use MAP0210 General problem resolution |
| 973-150 | 973
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution |
| 973-160 | 973
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution |
| 973-169 | 973
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution |
| 973-170 | 973
B88 media |
The Read, Write and Compare test failed. Action: Use MAP0210 General problem resolution |
| 973-180 | 973
media |
The Load command failed. Action: Use MAP0210 General problem resolution |
| 973-185 | 973
media |
The Unload command failed. Action: Use MAP0210 General problem resolution |
| 973-190 | 973 | The Mode Select command failed. Action: Use MAP0210 General problem resolution |
| 973-200 | 973
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution |
| 973-210 | 973
B88 |
The device configuration failed. Action: Use MAP0210 General problem resolution |
| 973-220 | 973 | The Release command failed. Action: Use MAP0210 General problem resolution |
| 973-230 | 973 | The Request Sense command failed. Action: Use MAP0210 General problem resolution |
| 973-240 | 973 | The Openx command failed. Action: Use MAP0210 General problem resolution |
| 973-300 | 973
software |
The device configuration failed. Action: Use MAP0210 General problem resolution |
| 973-310 | B88
973 software |
SCSI adapter configuration failed. Action: Use MAP0210 General problem resolution |
| 973-320 | 973
media |
Error log analysis indicates a failure. Action: Use MAP0210 General problem resolution |
| 973-411
to 973-423 |
973
B88 software |
A reservation conflict occurred. Action: Use MAP0210 General problem resolution |
| 973-511
to 973-523 |
973
B88 |
The drive returned bad or non-extended sense data. Action: Use MAP0210 General problem resolution |
| 973-611
to 973-623 |
973
B88 software |
An adapter or bus I/O error occurred. Action: Use MAP0210 General problem resolution |
| 973-711
to 973-723 |
973
B88 software |
A device timeout error occurred. Action: Use MAP0210 General problem resolution |
| 974-111 | 974
B88 |
Unable to reserve device. Action: Use MAP0210 General problem resolution |
| 974-112 | 974
B88 |
Unable to do configuration. Action: Use MAP0210 General problem resolution |
| 974-113 | 974
B88 |
Unable to open the device driver. Action: Use MAP0210 General problem resolution |
| 974-121 | 974 | The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution |
| 974-122 | 974 | The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution |
| 974-123 | 974 | The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution |
| 974-125 | 974
B88 |
The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution |
| 974-126 | 974 | The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution |
| 974-127 | 974 | The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution |
| 974-128 | 974 | The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution |
| 974-129 | 974 | The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution |
| 974-150 | Test-
Disc 974 |
A media error was detected. Action: Use MAP0210 General problem resolution |
| 974-151 | 974
D88 |
A command timeout was detected. Action: Use MAP0210 General problem resolution |
| 974-152 | 974 | A command reservation conflict was detected. Action: Use MAP0210 General problem resolution |
| 974-162 | 974 | The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution |
| 974-171 | 974 | Unable to reserve device. Action: Use MAP0210 General problem resolution |
| 974-172 | 974 | Unable to do configuration. Action: Use MAP0210 General problem resolution |
| 974-173 | 974 | Unable to open device driver. Action: Use MAP0210 General problem resolution |
| 974-175 | 974 | The CD-ROM drive indicates an error. Action: Use MAP0210 General problem resolution |
| 974-198 | 974
B88 |
Undefined error detected. Action: Use MAP0210 General problem resolution |
| 974-199 | 974 | Undefined error detected. Action: Use MAP0210 General problem resolution |
| 974-211 | 974 | The LED test failed. Action: Use MAP0210 General problem resolution |
| 974-281 | 974 | No tone during audio test. Action: Use MAP0210 General problem resolution |
| 974-301 | 974 | Errors found during ELA. Action: Use MAP0210 General problem resolution |
| 974-302 | 974
B88 |
Errors log analysis indicates hardware failure. Action: Use MAP0210 General problem resolution |
| 981-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 984-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 986-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 989-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 980-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 991-101 | 991 | Timeout while attempting to communicate with SCSI device. Action: Use MAP0210 General problem resolution |
| 991-102 | 991 | The SCSI device indicates busy. Action: Use MAP0210 General problem resolution |
| 991-103 | 991 | The SCSI device is indicating a reservation conflict. Action: Use MAP0210 General problem resolution |
| 991-104 | 991 | The SCSI device indicates a check condition. Action: Use MAP0210 General problem resolution |
| 991-105 | 991 | Sense data from the SCSI device shows an error. Action: Use MAP0210 General problem resolution |
| 991-107 | 991 | The SCSI drive returned unexpected sense data. Action: Use MAP0210 General problem resolution |
| 991-110 | 991 | The Reserve command failed. Action: Use MAP0210 General problem resolution |
| 991-111 | 991 | Invalid condition from the drive after a reserve. Action: Use MAP0210 General problem resolution |
| 991-112 | 991 | The write-protect sensor test failed. Action: Use MAP0210 General problem resolution |
| 991-113 | 991 | Invalid condition from the drive after a request sense. Action: Use MAP0210 General problem resolution |
| 991-114 | 991 | Timeout while attempting to communicate with the SCSI device. Action: Use MAP0210 General problem resolution |
| 991-120 | 991 | The Inquiry command failed. Action: Use MAP0210 General problem resolution |
| 991-130 | 991
media |
The Load command failed. Action: Use MAP0210 General problem resolution |
| 991-135 | 991
media |
The Unload command failed. Action: Use MAP0210 General problem resolution |
| 991-140 | 991 | The Mode Select command failed. Action: Use MAP0210 General problem resolution |
| 991-150 | 991
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution |
| 991-160 | 991
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution |
| 991-161 | 991
B88 |
Invalid condition from the drive after a reserve. Action: Use MAP0210 General problem resolution |
| 991-163 | 991
B88 |
Invalid condition from the drive after a request sense. Action: Use MAP0210 General problem resolution |
| 991-164 | 991
B88 |
Timeout while attempting to communicate with the SCSI device. Action: Use MAP0210 General problem resolution |
| 991-165 | 991
B88 276 |
Write, Read and Compare Test failed. Action: Use MAP0210 General problem resolution |
| 991-166 | 991
B88 software |
The device failed to configure. Action: Use MAP0210 General problem resolution |
| 991-167 | 991
B88 |
An unexpected SCSI error occurred. Action: Use MAP0210 General problem resolution |
| 991-168 | B88
software |
The adapter failed to configure. Action: Use MAP0210 General problem resolution |
| 991-169 | 991
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution |
| 991-170 | 991
B88 media |
The Read, Write and Compare test failed. Action: Use MAP0210 General problem resolution |
| 991-180 | 991
media |
The Load command failed. Action: Use MAP0210 General problem resolution |
| 991-185 | 991
media |
The Unload command failed. Action: Use MAP0210 General problem resolution |
| 991-190 | 991 | The Mode Select command failed. Action: Use MAP0210 General problem resolution |
| 991-200 | 991
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution |
| 991-201 | 991
B88 |
An error is diagnosed from the error log analysis. Action: Use MAP0210 General problem resolution |
| 991-210 | 991
B88 |
The device configuration failed. Action: Use MAP0210 General problem resolution |
| 991-211 | 991
B88 |
The device open test failed. Action: Use MAP0210 General problem resolution |
| 991-220 | 991 | The Release command failed. Action: Use MAP0210 General problem resolution |
| 991-230 | 991 | The Request Sense command failed. Action: Use MAP0210 General problem resolution |
| 991-240 | 991 | The Openx command failed. Action: Use MAP0210 General problem resolution |
| 991-260 | 991 | The device configuration failed. Action: Use MAP0210 General problem resolution |
| 991-261 | 991 | The device open test failed. Action: Use MAP0210 General problem resolution |
| 991-300 | 991
software |
The device configuration failed. Action: Use MAP0210 General problem resolution |
| 991-310 | B88
991 software |
SCSI adapter configuration failed. Action: Use MAP0210 General problem resolution |
| 991-320 | 991
media |
Error log analysis indicates a failure. Action: Use MAP0210 General problem resolution |
| 991-411
to 991-423 |
991
B88 software |
A reservation conflict occurred. Action: Use MAP0210 General problem resolution |
| 991-511
to 991-523 |
991
B88 |
The drive returned bad or non-extended sense data. Action: Use MAP0210 General problem resolution |
| 991-611
to 991-623 |
991
B88 software |
An adapter or bus I/O error occurred. Action: Use MAP0210 General problem resolution |
| 991-711
to 991-723 |
991
B88 software |
A device timeout error occurred. Action: Use MAP0210 General problem resolution |
| 994-110 | 994 | The Reserve command failed. Action: Use MAP0210 General problem resolution |
| 994-120 | 994 | The Inquiry command failed. Action: Use MAP0210 General problem resolution |
| 994-130 | 994
media |
The Load command failed. Action: Use MAP0210 General problem resolution |
| 994-135 | 994
media |
The Unload command failed. Action: Use MAP0210 General problem resolution |
| 994-140 | 994 | The Mode Select command failed. Action: Use MAP0210 General problem resolution |
| 994-150 | 994
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution |
| 994-160 | 994
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution |
| 994-169 | 994
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution |
| 994-170 | 994
B88 media |
The Read, Write and Compare test failed. Action: Use MAP0210 General problem resolution |
| 994-180 | 994
media |
The Load command failed. Action: Use MAP0210 General problem resolution |
| 994-185 | 994
media |
The Unload command failed. Action: Use MAP0210 General problem resolution |
| 994-190 | 994 | The Mode Select command failed. Action: Use MAP0210 General problem resolution |
| 994-200 | 994
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution |
| 994-210 | 994
B88 |
The device configuration failed. Action: Use MAP0210 General problem resolution |
| 994-220 | 994 | The Release command failed. Action: Use MAP0210 General problem resolution |
| 994-230 | 994 | The Request Sense command failed. Action: Use MAP0210 General problem resolution |
| 994-240 | 994 | The Openx command failed. Action: Use MAP0210 General problem resolution |
| 994-300 | 994
software |
The device configuration failed. Action: Use MAP0210 General problem resolution |
| 994-310 | B88
994 software |
SCSI adapter configuration failed. Action: Use MAP0210 General problem resolution |
| 994-320 | 994
media |
Error log analysis indicates a failure. Action: Use MAP0210 General problem resolution |
| 994-411
to 994-423 |
994
B88 software |
A reservation conflict occurred. Action: Use MAP0210 General problem resolution |
| 994-511
to 994-523 |
994
B88 |
The drive returned bad or non-extended sense data. Action: Use MAP0210 General problem resolution |
| 994-611
to 994-623 |
994
B88 software |
An adapter or bus I/O error occurred. Action: Use MAP0210 General problem resolution |
| 994-711
to 994-723 |
994
B88 software |
A device timeout error occurred. Action: Use MAP0210 General problem resolution |
| 995-110 | 995 | The Reserve command failed. Action: Use MAP0210 General problem resolution |
| 995-120 | 995 | The Inquiry command failed. Action: Use MAP0210 General problem resolution |
| 995-130 | 995
media |
The Load command failed. Action: Use MAP0210 General problem resolution |
| 995-135 | 995
media |
The Unload command failed. Action: Use MAP0210 General problem resolution |
| 995-140 | 995 | The Mode Select command failed. Action: Use MAP0210 General problem resolution |
| 995-150 | 995
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution |
| 995-160 | 995
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution |
| 995-169 | 995
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution |
| 995-170 | 995
B88 media |
The Read, Write and Compare test failed. Action: Use MAP0210 General problem resolution |
| 995-180 | 995
media |
The Load command failed. Action: Use MAP0210 General problem resolution |
| 995-185 | 995
media |
The Unload command failed. Action: Use MAP0210 General problem resolution |
| 995-190 | 995 | The Mode Select command failed. Action: Use MAP0210 General problem resolution |
| 995-200 | 995
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution |
| 995-210 | 995
B88 |
The device configuration failed. Action: Use MAP0210 General problem resolution |
| 995-220 | 995 | The Release command failed. Action: Use MAP0210 General problem resolution |
| 995-230 | 995 | The Request Sense command failed. Action: Use MAP0210 General problem resolution |
| 995-240 | 995 | The Openx command failed. Action: Use MAP0210 General problem resolution |
| 995-300 | 995
software |
The device configuration failed. Action: Use MAP0210 General problem resolution |
| 995-310 | B88
995 software |
SCSI adapter configuration failed. Action: Use MAP0210 General problem resolution |
| 995-320 | 995
media |
Error log analysis indicates a failure. Action: Use MAP0210 General problem resolution |
| 995-411
to 995-423 |
995
B88 software |
A reservation conflict occurred. Action: Use MAP0210 General problem resolution |
| 995-511
to 995-523 |
995
B88 |
The drive returned bad or non-extended sense data. Action: Use MAP0210 General problem resolution |
| 995-611
to 995-623 |
995
B88 software |
An adapter or bus I/O error occurred. Action: Use MAP0210 General problem resolution |
| 995-711
to 995-723 |
995
B88 software |
A device timeout error occurred. Action: Use MAP0210 General problem resolution |
| 998-110 | 998 | The Reserve command failed. Action: Use MAP0210 General problem resolution |
| 998-120 | 998 | The Inquiry command failed. Action: Use MAP0210 General problem resolution |
| 998-130 | 998
media |
The Load command failed. Action: Use MAP0210 General problem resolution |
| 998-135 | 998
media |
The Unload command failed. Action: Use MAP0210 General problem resolution |
| 998-140 | 998 | The Mode Select command failed. Action: Use MAP0210 General problem resolution |
| 998-150 | 998
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution |
| 998-160 | 998
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution |
| 998-169 | 998
media |
The Send Diagnostic command failed. Action: Use MAP0210 General problem resolution |
| 998-170 | 998
B88 media |
The Read, Write and Compare test failed. Action: Use MAP0210 General problem resolution |
| 998-180 | 998
media |
The Load command failed. Action: Use MAP0210 General problem resolution |
| 998-185 | 998
media |
The Unload command failed. Action: Use MAP0210 General problem resolution |
| 998-190 | 998 | The Mode Select command failed. Action: Use MAP0210 General problem resolution |
| 998-200 | 998
media |
The Test Unit Ready command failed. Action: Use MAP0210 General problem resolution |
| 998-210 | 998
B88 |
The device configuration failed. Action: Use MAP0210 General problem resolution |
| 998-220 | 998 | The Release command failed. Action: Use MAP0210 General problem resolution |
| 998-230 | 998 | The Request Sense command failed. Action: Use MAP0210 General problem resolution |
| 998-240 | 995 | The Openx command failed. Action: Use MAP0210 General problem resolution |
| 998-300 | 995
software |
The device configuration failed. Action: Use MAP0210 General problem resolution |
| 998-310 | B88
995 software |
SCSI adapter configuration failed. Action: Use MAP0210 General problem resolution |
| 998-320 | 995
media |
Error log analysis indicates a failure. Action: Use MAP0210 General problem resolution |
| 998-411
to 998-423 |
998
B88 software |
A reservation conflict occurred. Action: Use MAP0210 General problem resolution |
| 998-511
to 998-523 |
998
B88 |
The drive returned bad or non-extended sense data. Action: Use MAP0210 General problem resolution |
| 998-611
to 998-623 |
998
B88 software |
An adapter or bus I/O error occurred. Action: Use MAP0210 General problem resolution |
| 998-711
to 998-723 |
998
B88 software |
A device timeout error occurred. Action: Use MAP0210 General problem resolution |
| 999-xxx series | 999 | A 7137 or 3514 disk array subsystem problem is indicated. Action: Use 7137 or 3514 documentation. |
| 9CC-1xx | I/O Error on PCI bus. Action: Refer to the Bus SRN to
FRU Reference Table in the system unit's service guide. Note: xx represents
the last 2 digits of the SRN.
|
|
| 9CC-xxx | xxx
2C9 |
I/O Bus Data, Address Parity Error, or Time-out error.
Note: xxx represents the last 3 digits of the SRN.
Action:
Use MAP0210 General problem resolution |