MAP4A30 CCL code update process was manually suspended

A CCL code update process has been manually suspended by the service representative using the HMC Emergency Update Utility option Suspend Code Update.

About this task

This would occur for one of the following reasons:
  • Directed by MAP4A00 HMC failure with CCL code update or code update utility still active
  • A service representative suspended the CCL code update for an unknown reason.

There should not be an additional serviceable event as the code update process was manually suspended, and not suspended by the code update process discovering an unexpected serviceable event.

MAP4A30 Section-1

Procedure

  1. In addition to the serviceable event that sent you here, are there any other open serviceable events?
    • Yes, go to the next step.
    • No, continue with step 3.
  2. Display the serviceable event details for the other serviceable event that did not send you here. Use Table 1 to prioritize the repair sequence.
    Note: You will not be able to reselect the serviceable event in the original window that you used to select it when you began this repair. Instead, return to the main HMC menu selection and repeat the steps to view serviceable events.
    Table 1. MAP4A30 repair prioritization
    Serviceable event type Repair Sequence Action
    CEC enclosure serviceable event 1 Repair serviceable event and then return here and continue.
    All other problems except any serviceable event with MAP4A50 in the FRU list. 2 Repair serviceable event and then return here and continue.
    Serviceable event with MAP4A50 in FRU list. 3 Repair serviceable event and then return here and continue.
    All other serviceable events repaired. 4 Go to the next step.
  3. Exit this MAP and go to MAP4A60. Verify resources before restarting CDA CCL.