(1xxxxxxx) System power control network (SPCN) reference codes

The system power control network (SPCN) reference codes are described in this topic.

The system power control network (SPCN) detected a failure.

Note: The second and third characters of the system reference code (SRC) indicate the frame number of the failing unit.
  1. Look at the four rightmost characters of the SRC for Function 11 or Function 5. These characters are the unit reference code.
  2. Find the unit reference code in the following tables, depending on the system model.
For details on the Failing Item column entries, see the Table 2.
If you do not find an SRC in the table that follows, contact your next level of support for assistance.
Notes:
  1. The SRCs on this page are from the Power Systems hardware documentation, and the Descriptions apply to a single CEC enclosure or I/O enclosure. The Action and Failing Item fields are modified as appropriate for DS8000® architecture and repair methods.
  2. SRCs missing from the following tables might be found on the Power Systems online documentation. You can use the SRC description as is to define the problem. Do not use the Action and Failing Item without contacting the next level of support first.
  3. To display the Power Systems hardware online documentation, go to the Web site http://www-01.ibm.com/support/knowledgecenter/.
    • In the IBM Systems Hardware Information right content pane, click POWER6 reference codes listing.
Table 1. SPCN reference codes
SRC Description/Action Failing Item
1xxx00A0 SPCN BATs in process

No action required. This reference code is logged for information only. If this reference code is present for more than 1 minute, exchange the failing items.

TWRCARD
1xxx00AA Download in process

No action required. This reference code is logged for information only.

 
1xxx00AC Detected AC loss

If system powers on normally or stays powered on after AC power failure, no replacement of parts may be needed.

ACMODUL
1xxx00AD Service Processor Reset caused a system power off. TWRCARD
1xxx00BA The system is running on the Battery Power Unit

No action required. This reference code is displayed for information only.

 
1xxx00BC Battery Power Unit test is in process

No action required. This reference code is displayed for information only.

 
1xxx00CA Thermal calibration in progress  
1xxx00EF Remote EPO switch is OFF  
1xxx1500 Detected AC loss

Before replacing any parts, verify that the AC input voltage is correct.

PWRSPLY

TWRCARD

1xxx1501 Power supply failure PWRSPLY

TWRCARD

1xxx1502 Power supply failure PWRSPLY

TWRCARD

CBLALL

1xxx1503 Power supply failure PWRSPLY

TWRCARD

1xxx1510 Detected AC loss

Before replacing any parts, verify that the AC input voltage is correct.

PWRSPLY

TWRCARD

1xxx1511 Power supply failure

PWRSPLY

TWRCARD

1xxx1512 Power supply failure PWRSPLY

TWRCARD

CBLALL

1xxx1513 to 1xxx1514 Power supply failure PWRSPLY

TWRCARD

1xxx1516 No Power Supplies Present

The required power supplies are not installed.

PWRSPLY

TWRCARD

1xxx1517 Power supply failure PWRSPLY

TWRCARD

1xxx151E The power supply fan on Un-E1 experienced a short stoppage, but recovered. The power supply should be replaced as soon as possible before the fan fails permanently.

Follow the instructions for the items listed in the FRU List.

PWRSPLY

TWRCARD

1xxx151F The power supply fan on Un-E1 failed. The power supply should be replaced as soon as possible.

Follow the instructions for the items listed in the FRU List.

PWRSPLY

TWRCARD

1xxx1520 Detected AC loss

Before replacing any parts, verify that the AC input voltage is correct.

PWRSPLY

TWRCARD

1xxx1521 Power supply failure PWRSPLY

TWRCARD

1xxx1522 Power supply failure PWRSPLY

TWRCARD

CBLALL

1xxx1523 to 1xxx1524 Power supply failure PWRSPLY

TWRCARD

1xxx1526 No Power Supplies Present

The required power supplies are not installed.

PWRSPLY

TWRCARD

1xxx1527 Power supply failure PWRSPLY

TWRCARD

1xxx152E The power supply fan on Un-E2 experienced a short stoppage, but recovered. The power supply should be replaced as soon as possible before the fan fails permanently.

Follow the instructions for the items listed in the FRU List.

PWRSPLY

TWRCARD

1xxx152F The power supply fan on Un-E2 failed. The power supply should be replaced as soon as possible.

Follow the instructions for the items listed in the FRU List.

PWRSPLY

TWRCARD

1xxx1530 Detected AC loss

Before replacing any parts, verify that the AC input voltage is correct.

PWRSPLY

TWRCARD

1xxx1531 Power supply failure PWRSPLY

TWRCARD

1xxx1532 Power supply failure PWRSPLY

TWRCARD

CBLALL

1xxx1533 Power supply failure PWRSPLY

TWRCARD

1xxx1611 Regulator 1 Fault

PWR1918

TWRCARD

1xxx1612 Regulator 1 Communication Fault

PWR1918

TWRCARD

1xxx1613 Regulator 1 Domain Fault

PWR1918

TWRCARD

1xxx1621 Regulator 2 Fault

PWR1918

TWRCARD

1xxx1622 Regulator 2 Communication Fault

PWR1918

TWRCARD

1xxx1623 Regulator 2 Domain Fault

PWR1918

TWRCARD

1xxx1631 Regulator 3 Fault

PWR1918

TWRCARD

1xxx1632 Regulator 3 Communication Fault

PWR1918

TWRCARD

1xxx1633 Regulator 3 Domain Fault

PWR1918

TWRCARD

1xxx1B01 Load fault on the +12V bus

PWR1900

TWRCARD

1xxx1B02 Load fault on the +5V bus

PWR1900

TWRCARD

1xxx1B03 Load fault on the +3.3V bus

PWR1900

TWRCARD

1xxx1B04 Load fault on the -12V bus

PWR1900

TWRCARD

1xxx1B05 Load fault on the +1.8V bus

PWR1904

TWRCARD

1xxx1B06 Load fault on the +2.5V bus

PWR1904

TWRCARD

1xxx1B0A Load Fault on the +12V/-12v bus

PWR1904

TWRCARD

1xxx1B0F Load Fault on the +1.2V bus

PWR1904

TWRCARD

1xxx1C02 Load Fault on the +1.2V bus

PWR1904

TWRCARD

1xxx1C04 Load Fault on the +1.5V bus

PWR1904

TWRCARD

1xxx1C06 Load Fault on the 1.8/2.5V bus

PWR1904

TWRCARD

1xxx1D00 to 1xxx1D01 FSP Card SS Fault CARDFLT
1xxx1D02 to 1xxx1D03 OSC Card SS Fault CARDFLT
1xxx1D04 to 1xxx1D05 Lightstrip SS Fault CARDFLTLITSTRPCABLEH
1xxx1D10 MUX Card SS Fault CARDFLT
1xxx1D11 to 1xxx1D18 IO Hub Card SS Fault CARDFLT
1xxx1D60 RIO/HSL Adapter Card Switch fault

SI_CARD

TWRCARD

1xxx1D61 to 1xxx1D62 Removable Media Planar Switch fault

DEVBPLN

TWRCARD

1xxx1F01 SPCN trace information saved  
1xxx1F02 SPCN trace information saved  
1xxx2600 Power Good Fault

PGDPART

TWRCARD

PWRSPLY

1xxx2601 Power Good Fault

PGDPART

TWRCARD

1xxx2602 Power Good Fault

PWR1918

TWRCARD

1xxx2603 Power Good Fault

PWR1916

TWRCARD

1xxx2605 to 1xxx2606 Power Good Fault

PWR1900

TWRCARD

1xxx2612 Optical Converter 5V Fault

The SPCN detected a fault on the SPCN card optical converter 5V.

CBLALL

TWRCARD

1xxx2613 Configuration Requires 200V Input

Configuration now requires 200 V ac power.

CBLALL
1xxx2630 to 1xxx2632 Regulator Fault

PWR1918

TWRCARD

1xxx2633 to 1xxx2635 Regulator Fault SYSBKPLTWRCARD
1xxx2636 to 1xxx2637, 1xxx2640 to 1xxx2642 Regulator Fault

PWR1918

TWRCARD

1xxx3100 I2C Bus Controller Communication fault

I2CBUS

TWRCARD

1xxx3101 I2C Bus 1 Communication fault

I2CBUS

TWRCARD

1xxx3102 I2C Bus 2 Communication fault

I2CBUS

TWRCARD

1xxx3103 I2C Bus 3 Communication fault

I2CBUS

TWRCARD

1xxx3104 I2C Bus 4 Communication fault

I2CBUS

TWRCARD

1xxx3105 I2C Bus 5 Communication fault

I2CBUS

TWRCARD

1xxx3106 I2C Bus 6 Communication fault

I2CBUS

TWRCARD

1xxx3109 I2C Bus Adapter Communication fault

I2CBUS

TWRCARD

1xxx3110 I2C Bus DASD Backplane 1 Communication fault

I2CBUS

TWRCARD

1xxx3111 I2C Bus DASD Backplane 2 Communication fault

I2CBUS

TWRCARD

1xxx3112 I2C Bus DASD Backplane 3 Communication fault

I2CBUS

TWRCARD

1xxx3113 I2C Bus Adapter Communication fault

I2CBUS

TWRCARD

1xxx3114 I2C Bus PCI Backplane Communication fault

I2CBUS

TWRCARD

1xxx3115 I2C Bus Panel Communication fault

I2CBUS

TWRCARD

1xxx3116 I2C Bus Fan Local Controller Communication fault

I2CBUS

TWRCARD

1xxx3118 I2C Bus SPCN VPD Communication fault

I2CBUS

TWRCARD

1xxx3119 I2C Bus 4 Communication fault

I2CBUS

TWRCARD

1xxx3120 I2C Bus LED Controller Communication fault TWRCARD
1xxx3121 I2C Bus DASD Backplane 1 Communication fault

I2CBUS

TWRCARD

1xxx3130 Panel Thermal Sensor Communication fault

I2CBUS

TWRCARD

1xxx3131 Removable Media Thermal Sensor Communication fault

I2CBUS

TWRCARD

1xxx3132 Processor 1 Thermal Sensor Communication fault

I2CBUS

TWRCARD

1xxx3133 Processor 2 Thermal Sensor Communication fault

I2CBUS

TWRCARD

1xxx4201 UPS Reported, Utility Failure On  
1xxx4203 UPS Reported, Battery Low On  
1xxx4410 Internal Battery Power Unit Fault

Internal Battery Power Unit in the system has failed.

BATRY

BATCHGR

TWRCARD

CBLALL

1xxx4411 Internal Battery Power Unit Charger Fault

Internal Battery Power Unit Charger in the system has failed.

BATCHGR

TWRCARD

CBLALL

1xxx4412 Internal Battery Power Unit Charger Fault

Internal Battery Power Unit Charger in the system has failed.

BATCHGR

TWRCARD

CBLALL

1xxx4413 Internal Battery Power Unit Charger Fault

Internal Battery Power Unit Charger in the system has failed.

BATRY

BATCHGR

TWRCARD

CBLALL

1xxx4414 Battery Charger Load fault

PWROC

BATRY

TWRCARD

CBLALL

1xxx4415 Battery Power Unit missing

BATRY

TWRCARD

CBLALL

1xxx4417 Battery Charger Unit missing

BATCHGR

TWRCARD

CBLALL

1xxx4600 to 1xxx4601 UPS Interface Failure

UPSUNIT

TWRCARD

1xxx5000 to 1xxx5001 5000 to 5001 TWRCARD
1xxx7110, 1xxx7120 Power supply failure PWRSPLY

TWRCARD

1xxx7201 Ambient temperature is out of range AMBTEMP
1xxx7202 Ambient temperature is back in range  
1xxx7203 Ambient temperature exceeded limit

(System will shut down in 15 minutes.)

AMBTEMP
1xxx7205 Ambient temperature exceeded limit

(System will shut down in 20 minutes.)

AMBTEMP
1xxx7300 Power supply failure

PWRSPLY

TWRCARD

1xxx7610 Fan Fault

The Fan is operating at the wrong speed.

AIRMOVR

TWRCARD

1xxx7611 Fan missing error

A problem was detected with a Fan which can be caused by a Fan not being installed. Install Fan if missing, replace if already installed.

AIRMOVR

TWRCARD

1xxx7620 Fan Fault

The Fan is operating at the wrong speed.

AIRMOVR

TWRCARD

1xxx7621 Fan missing error

A problem was detected with a Fan which can be caused by a Fan not being installed. Install Fan if missing, replace if already installed.

AIRMOVR

TWRCARD

1xxx7630 Fan Fault

The Fan is operating at the wrong speed.

AIRMOVR

TWRCARD

1xxx7631 Fan missing error

A problem was detected with a Fan which can be caused by a Fan not being installed. Install Fan if missing, replace if already installed.

AIRMOVR

TWRCARD

1xxx7640 Fan Fault

The Fan is operating at the wrong speed.

AIRMOVR

TWRCARD

1xxx7641 Fan missing error

A problem was detected with a Fan which can be caused by a Fan not being installed. Install Fan if missing, replace if already installed.

AIRMOVR

TWRCARD

1xxx7650 Fan Fault

AIRMOVR

TWRCARD

1xxx7651 Fan missing error

AIRMOVR

TWRCARD

1xxx7690 Fan Fault

AIRMOVR

TWRCARD

1xxx7691 Fan missing error

AIRMOVR

TWRCARD

1xxx8400 No VPD Found due to Invalid Bypass TWRCARD
1xxx8401 Timeout on Panel for Request of VPD

VPDPART

TWRCARD

1xxx8402 Unable to Collect VPD

VPDPART

TWRCARD

1xxx8403 VPD Critical Mismatch

VPDPART

TWRCARD

1xxx8404 to 1xxx8406 Processor Unit VPD Mismatch

VPDPART

TWRCARD

1xxx8409 No Processor Installed

VPDPART

TWRCARD

1xxx8410 to 1xxx8417 Invalid Processor VPD

VPDPART

TWRCARD

1xxx8420 to 1xxx8427 No Processor VPD

VPDPART

TWRCARD

1xxx840A VPD 5V Power Off Failure

VPDPART

TWRCARD

1xxx840B VPD 5V Power On Failure

VPDPART

TWRCARD

1xxx840D SPCN Configuration mismatch

VPDPART

TWRCARD

1xxx840E SPCN Default Configuration loaded

VPDPART

TWRCARD

1xxx8413 to 1xxx8414 Invalid Processor VPD

VPDPART

TWRCARD

1xxx8423 to 1xxx8424 No Processor VPD

VPDPART

TWRCARD

1xxx8430 Cable not connected

IDPART

TWRCARD

CBLALL

1xxx8431 Cable should not be present

IDPART

TWRCARD

CBLALL

1xxx8432 Secondary unit not present

IDPART

TWRCARD

CBLALL

1xxx8450 to 1xxx8451 SPCN Configuration mismatch

PWR1918

TWRCARD

1xxx8455 to 1xxx8456 Power Supply Missing PWRSPLY

TWRCARD

1xxx8470 to 1xxx8477 Processor Unit VPD Mismatch VPDPART

TWRCARD

1xxx8700 to 1xxx8701 BPC AC Loss PWR2402
1xxx8710 to 1xxx8711 DCA UART Communication Fault DCA

TWRCARD

SYSBKPL

1xxx8720 to 1xxx8721 BPC Ethernet Communication fault CABLEH

BPC

TWRCARD

1xxx8731 BPC critical fault, no present node books powered on CABLEH

NEXTLVL

1xxx8732 BPC critical fault, CEC cage id mismatch - cabling error CABLEH

NEXTLVL

1xxx8733 BPC critical fault, no node books present to power on CABLEH

NEXTLVL

1xxx8734 BPC fault, fips log collection failed CABLEH

NEXTLVL

1xxx8735 BPC/HMC fault, No BPC IP addresses BPC
1xxx8740 to 1xxx8741 BPC fault, failed to reach standby BPC
1xxx8910 External Netfinity Server 3.3V fault

ALTMANL

TWRCARD

1xxx8920 External Netfinity Server Power Good fault

ALTMANL

TWRCARD

1xxx8930 Integrated Netfinity Adapter fault TWRCARD
1xxx8940 to 1xxx8943 External Netfinity Server R485 Communication fault

TWRCARD

CBLALL

1xxx8A00 IO Power control changed to another system unit  
1xxx9002 Received a bad return code

Partition Firmware has detected a condition that may require attention. Check error log for other errors that may have been reported at the same time as this condition was reported. If this SRC persists contact next level of support.

 
1xxx9012 Address not valid

LIC command had a frame address that was not valid.

Exchange the SPCN frame-to-frame cables to the failing frame.

TWRCARD

CBLALL

1xxx9013 Invalid Node Address

The address in the SPCN command does not match the secondary nodes assigned address.

Exchange the failing items for the SPCN node reporting the error.

TWRCARD

CBLALL

1xxx9014 A command has an invalid address mode.

A command from the system unit specified a unit address of D or E or had a frame address of 00.

Exchange the failing items in the system unit.

AJDG301

TWRCARD

1xxx9016, 1xxx9021 A command to an SPCN node was rejected.

No action required. This reference code is logged for information only.

 
1xxx9022 Addressed Unit not in frame.

The addressed unit is in a frame that is powered off.

No action required. This reference code is logged for information only.

 
1xxx9023 Addressed Unit exists, but the frame is powered off.

The addressed unit is in a frame that is powered off.

No action required. This reference code is logged for information only.

 
1xxx9024 SPCN Licensed Internal Code not valid.

The Licensed Internal Code in one of the secondary nodes is not valid. The code will be reloaded.

No action required. This reference code is logged for error analysis only.

 
1xxx9025 SPCN Licensed Internal Code not valid.

The Licensed Internal Code in one of the frames is not valid. The code will be reloaded.

No action required. This reference code is logged for error analysis only.

 
1xxx9026 Battery Power Unit is reporting a low charge.

The battery power unit is not charged enough to run a test.

No action required. This reference code is logged for information only.

 
1xxx9027 Battery Power Unit is defective.

No action required. This reference code is logged for information only.

 
1xxx9028 SPCN Licensed Internal Code is not valid.

The Licensed Internal Code in the primary node is not valid. The code will be reloaded.

No action required. This reference code is logged for error analysis only.

 
1xxx9029 SPCN VPD Damaged

The VPD record in the EEPROM has bad data.

Exchange the failing items for the node reporting the failure.

TWRCARD
1xxx902C Battery Power Unit test was aborted.

The battery power unit test was aborted.

No action required. This reference code is logged for information only.

 
1xxx902D Addressed frame is not in SPCN configuration table.

The addressed frame is not in the SPCN configuration table.

No action required. This reference code is logged for information only.

 
1xxx9031 Frame-to-Frame Communications Failure

The SPCN detected a BCC error on a transmission from another frame. The transmission is attempted again.

No action required. This reference code is logged for error analysis only.

 
1xxx9032 SPCN Communications Failure, unit to rack.

The frame detected a BCC error on a transmission from a secondary node to the frame. The transmission is attempted again.

No action required. This reference code is logged for error analysis only.

 
1xxx9033 SPCN Communications Failure, rack to unit.

A secondary node detected a BCC error on a transmission from the frame. The transmission is attempted again.

No action required. This reference code is logged for error analysis only.

 
1xxx9034 Unsupported Packet Size

The receiving node detected a packet exceeding 70 bytes. The frame can also return this code if a secondary node returns more than 10 bytes to a PAS command.

No action required. This reference code is logged for error analysis only.

 
1xxx9035 Secondary SPCN node timeout.

A secondary SPCN node did not respond to a command. The command was attempted again and failed.

No action required. This reference code is logged for error analysis only.

 
1xxx9036 Frame Timeout

One or more frames did not respond to a command. The command is attempted again.

No action required. This reference code is logged for error analysis only.

 
1xxx903B Invalid Packet Length for data sent.

The number of bytes sent or received does not match the number of bytes specified in the command.

No action required. This reference code is logged for error analysis only.

 
1xxx9041 Invalid Load Type

The down load was successful, but the wrong type of Licensed Internal Code was loaded. The operation was attempted again but was not successful. Exchange the failing items for the node reporting the fault.

AJDG301

TWRCARD

1xxx9042 EEPROM Failure

The EEPROM in an SPCN node cannot be written successfully.

Exchange the SPCN node reported in the failure.

TWRCARD
1xxx9043 Download Failure

The Licensed Internal Code download to an SPCN node was completed but was not successful.

Exchange the failing SPCN node.

TWRCARD
1xxx9046 QDS Packet Sequence Error

The Packet Sequence number is wrong. The download was stopped.

TWRCARD
1xxx9047 QDS Block Sequence Error

The Block Sequence number is wrong. The download was stopped.

TWRCARD
1xxx9048 The SPCN ROS and EEPROM LIC is not compatible.

The LIC levels in the nodes ROS and EEPROM are not compatible.

Exchange the failing items for the failing node.

TWRCARD

AJDG301

1xxx9080 Undefined Status Code

An SPCN node returned an unknown status code.

Exchange the failing SPCN node.

TWRCARD

BACKPLN

1xxx90F0 A frame was dropped from the SPCN configuration.

A frame was dropped from the SPCN configuration. This is usually caused by a loss of ac power or a problem with the frame-to-frame cable.

TWRCARD

CBLALL

1xxx90F1 A frame was added to the SPCN configuration.

No action required. This reference code is logged for information only.

 
1xxx90F2 Slave disappeared

A frame was dropped from the SPCN configuration. This is usually caused by a loss of ac power or a problem with the frame-to-frame cable.

PWR1907
1xxx90F3 Slave reappeared  
1xxx9101 VLIC-SPCN Timeout

A Licensed Internal Code timeout occurred. The SPCN failed to respond to a Licensed Internal Code command.

TWRCARD

CTLPNL

SVCPROC

1xxx9102 Assign Permanent Address command failure

A node failed to perform an Assign Permanent Address command.

TWRCARD
1xxx9103 Download Initialize Timeout

An SPCN node failed to enter the download state after an Initialize for Download command.

Exchange the failing SPCN node.

TWRCARD
1xxx9104 Download Initialize Timeout

An SPCN node failed to leave the download state.

Exchange the failing SPCN node.

TWRCARD
1xxx9105 Load Damaged Timeout

An SPCN node failed to enter the operational state.

Exchange the failing SPCN node.

TWRCARD
1xxx9106 An SPCN LID was not found.

No action required. This reference code is logged for information only.

 
1xxx9107 An SPCN microcode download is required.

No action required. This reference code is logged for error analysis only.

 
1xxx9108 A status change occurred in one of the SPCN nodes.

No action required. This reference code is logged for information only.

 
1xxx9109 Licensed Internal Code part number is not correct.

The AROS part number field was not updated to the correct level after the system attempted to load new Licensed Internal Code.

TWRCARD
1xxx910A RIO Download Required  
1xxx910B Maximum number of retries exceeded  
1xxx9110 Battery Power Unit capacity test failed.

The battery power unit was not able to pass the capacity test.

BATRY
1xxx9111 SPCN is too large for VLIC.

There are more nodes in the network than VLIC can service.

AJDG301
1xxx9112 Primary SPCN node is reporting load damaged.

The Licensed Internal Code for the primary SPCN node is damaged. The reload failed because the code could not be found.

TWRCARD
1xxx9113 Secondary SPCN node is reporting load damaged.

The Licensed Internal Code for the secondary SPCN node is damaged. The reload failed because the code could not be found.

TWRCARD
1xxx9114 Frame SPCN node is reporting load damaged.

The Licensed Internal Code for a SPCN node is damaged. The reload failed because the code could not be found.

TWRCARD
1xxx9115 SPCN Command rejected by the Service Processor.

The service processor rejected an SPCN command from the Licensed Internal Code.

No action required. This reference code is logged for information only.

 
1xxx9116 SPCN - Control Panel interface failure.

The SPCN to control panel interface is not working.

 
1xxx9117 SPCN - Control Panel interface is now working.

The SPCN to control panel interface is now working.

No action required. This reference code is logged for information only.

 
1xxx9118 PHYP out of memory AJDG301
1xxx9119 NVRAM Write Failed TWRCARD
1xxx911A Too many racks attached

Reduce the number of racks to maximum configuration on the system.

 
1xxx911B SPCN CEC node code failure AJDG301
1xxx911C Two nodes have same VPD VPDPART
1xxx911D RIO Download Failure TWRCARD
1xxx911E Temporary VPD written TWRCARD
1xxx911F CEC not found TWRCARD
1xxx9120 Duplicate backplane VPD SYSBKPL
1xxx9131 Invalid XM Return Code  
1xxx9132 Node contains temporary VPD  
1xxx9133 Bad PCI Correlation Problem

PCI bus not matched

CBLALL
1xxx9134 PCI bus VPD error

Check Error Log for B700xxxx Reference Codes.

 
1xxx9135 Open SPCN Loop CBLALL

TWRCARD

1xxx9137 Bad PCI Correlation Problem

SPCN node not matched

CBLALL
1xxx9138 Bad Location Code CBLALL
1xxx913B Go to ASMI to start a download manually PWR1907
1xxx91DD All SPCN Downloads Complete  
1xxx91DE RIO Download Complete  
1xxx91FB Write VPD on next IPL  
1xxx9212 Frame Address field not valid.

A Licensed Internal Code command had a frame address that is not valid.

Exchange the failing items for the failing node.

TWRCARD
1xxx9213 Invalid Address status, secondary node.

The address in the SPCN command does not match the assigned address of the secondary node.

Exchange the failing items for the failing node.

TWRCARD
1xxx9214 Invalid Address Mode status

Invalid Address Mode occurred during Frame Command processing.

TWRCARD

AJDG301

1xxx9215 Invalid Frame Command status

Invalid Frame Command occurred during Frame Command processing.

TWRCARD

AJDG301

1xxx921B System Unit SPCN Port Fault status.

System Unit Port Fault occurred during Command processing.

TWRCARD

AJDG301

1xxx922B Address Unassigned status

A secondary node has no address assigned during Command processing.

TWRCARD

AJDG301

1xxx9231 Frame-to-Frame Communications Failure

A frame-to-frame communications failure occurred during STF processing.

TWRCARD

CBLALL

1xxx9232 Intrarack Communications Failure

An SPCN secondary node to frame communications failure occurred during Command processing.

TWRCARD

CBLALL

1xxx9233 Intrarack Communications Failure

An SPCN frame to secondary node communications failure occurred during Command processing.

TWRCARD

CBLALL

1xxx9234 Unsupported Packet Size status

Unsupported Packet Size occurred during STF and Secondary Node Command processing.

TWRCARD

SVCPROC

1xxx9235 SPCN Secondary Node Timeout status

An SPCN Secondary Node Timeout occurred during Command processing.

TWRCARD

AJDG301

CBLALL

1xxx9236 Frame Timeout status

An SPCN Frame Node Timeout occurred during Network post processing.

TWRCARD

CBLALL

1xxx9238 Secondary Node Fault

An SPCN Secondary Node Fault occurred during Command processing.

TWRCARD

CBLALL

1xxx9239 Frame Node Fault

An internal error in the SPCN frame node prevents the running of a Frame command.

TWRCARD

CBLALL

1xxx923A ASA Failure

The frame address returned by a secondary node does not match the address of the frame.

TWRCARD

CBLALL

1xxx923B Invalid Packet Length for data sent.

An Invalid Packet Length occurred for data exchanged.

TWRCARD

CBLALL

1xxx9280 Response Stack Overflow

Too many responses were received during System Frame command processing.

CBLALL

AJDG301

TWRCARD

1xxx9281 Response Overrun

Response Overrun occurred during System Frame processing.

CBLALL

AJDG301

TWRCARD

1xxx9282 No Free Entries

No free entries were found during System Frame processing.

CBLALL

AJDG301

TWRCARD

1xxx9283 ARA Failure

An Assign Frame Address Failure occurred during ARA Preprocessing.

TWRCARD

AJDG301

1xxx9284 Undefined status

Undefined Status occurred during Frame or STF processing.

TWRCARD

CBLALL

1xxx9285 BCC Fault

A BCC Error was detected during Network post processing.

TWRCARD
1xxx9286 Length Check Error

Length Check occurred during SPCN post processing.

TWRCARD

CBLALL

1xxx9287 Undefined status

Undefined Status occurred during Command processing.

TWRCARD

CBLALL

1xxx9288 Configuration Error

A configuration error was detected during System Frame processing.

TWRCARD

CBLALL

1xxx9289 Invalid Packet Length for data sent.

Invalid Packet Length occurred for data exchanged.

TWRCARD

CBLALL

1xxxC62E SPCN Network Fault

An SPCN frame-to-frame communication failure was detected.

See Cannot power on I/O expansion tower or unit SRNPU or System or I/O expansion tower unit cannot be powered off POSORMU.

TWRCARD

CBLALL

1xxxCB15 EEPROM Failure TWRCARD
Table 2. SPCN failing items
Failing Item Description Document Description
ACMODUL AC Module See the service documentation for instructions.
AIRMOVR Fan and Blower assemblies See the service documentation for instructions.
AJDG301 Vertical Licensed Internal Code Service Functions; APAR or LICTR
ALTMANL Alternate Manual Required See the service documentation for instructions.
BACKPLN Back Plane Unit See the service documentation for instructions.
BATCHGR Battery Power Unit Charger See the service documentation for instructions.
BATRY Battery Power Unit See the service documentation for instructions.
BPC BPC Fault for eServer™ H See the service documentation for instructions.
CABLEH Cable all for eServer H See the service documentation for instructions.
CARDFLT Card Fault for eServer H See the service documentation for instructions.
CBLALL Cable Failure See the service documentation for instructions.
CTLPNL Control Panel See the service documentation for instructions.
DCA DCA fault for eServer H See the service documentation for instructions.
DEVBPLN Device backplane See the service documentation for instructions.
I2CBUS I2C Bus Part See the service documentation for instructions.
IDPART Vital Product Data Parts See the service documentation for instructions.
LITSTRP Litestrip for eServer H See the service documentation for instructions.
NEXTLVL Call for next level of support See the service documentation for instructions.
PGDPART Power Good Part See the service documentation for instructions.
PWR1900 Power-PIP 1900 See the service documentation for instructions.
PWR1902 Power-PIP 1902 See the service documentation for instructions.
PWR1903 Power-PIP 1903 See the service documentation for instructions.
PWR1904 Power-PIP 1904 See the service documentation for instructions.
PWR1906 Power-PIP 1906 See the service documentation for instructions.
PWR1907 Power-PIP 1907 INFORMATION
PWR1908 Power-PIP 1908 See the service documentation for instructions.
PWR1909 Power-PIP 1909 See the service documentation for instructions.
PWR1911 Power-PIP 1911 See the service documentation for instructions.
PWR1916 Power-PIP 1916 See the service documentation for instructions.
PWR1917 Power-PIP 1917 See the service documentation for instructions.
PWR1918 Power-PIP 1918 See the service documentation for instructions.
PWR2404 Power 2402 for eServer H See the service documentation for instructions.
PWROC Power Supply overcurrent See the service documentation for instructions.
PWRSPLY Power Supply See the service documentation for instructions.
SI_CARD System Interconnect controller See the service documentation for instructions.
SVCPROC Service Processor Card See the service documentation for instructions.
SYSBKPL System unit backplane See the service documentation for instructions.
TWRCARD Card enclosure or backplane See the service documentation for instructions.
UPSUNIT UPS unit part See the service documentation for instructions.
VPDPART VPD Communication Part See the service documentation for instructions.