(B7xxxxxx) Licensed Internal Code (LIC) reference codes

For use by service providers.

Use this table for B7xxxxxx reference codes.

Perform the following actions:

  1. Find the unit reference code by looking at characters 5 through 8 of the top 16 character line of function 11 (4 rightmost characters of word 1). These 4 characters are the unit reference code.
  2. Look up the unit reference code in Table 1.
  3. Perform the actions in the Description/Action column of the table.

In all cases, once the failing item is determined, go to the locations table for the system you are working on to determine the location, and use the remove and replace procedure for the failing item.

If you do not find an SRC in the table that follows, contact your next level of support for assistance.
Notes:
  1. The SRCs on this page are from the Power Systems hardware documentation, and the Descriptions apply to a single CEC enclosure or I/O enclosure. The Action and Failing Item fields are modified as appropriate for DS8000® architecture and repair methods.
  2. SRCs missing from the following tables might be found on the Power Systems online documentation. You can use the SRC description as is to define the problem. Do not use the Action and Failing Item without contacting the next level of support first.
  3. To display the Power Systems hardware online documentation, go to the Web site http://www-01.ibm.com/support/knowledgecenter/.
    • In the IBM Systems Hardware Information right content pane, click POWER6 reference codes listing.
Table 1. (B7xxxxxx) Licensed Internal Code (LIC) Reference Codes
SRC Description/Action Failing Item
B7xx0103 Platform LIC failure

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

The platform Licensed Internal Code (LIC) detected an internal problem. Collect all the SRC words and the platform system dump, and then contact your next level of support.

LICCODE
B7xx0106 Platform LIC failure

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

A secondary failure due to an invalid SRC occurred when the platform attempted to terminate.

Collect all the SRC words and the platform system dump, and then contact your next level of support.

LICCODE
B7xx0302 Platform LIC failure

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

Perform a platform system dump and notify your service provider. IPL the system.

LICCODE
B7xx0441 Service processor failure

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

The platform encountered an error early in the IPL or termination process.

SVCPROC

NEXTLVL
B7xx0443 Service processor failure

SVCPROC

NEXTLVL
B7xx0601 System log entry only, no service action required

Support can use this SRC and associated data to determine why the time of day for a partition was lost. No corrective action is required.

SVCDOCS
B7xx0602 Platform LIC detected an error

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

Platform Licensed Internal Code (LIC) detected an error condition. The second word indicates the severity of the error and the specific error condition. If word 2 is not 10000A01 the error is informational only. If word 2 is 10000A01, then record the SRC words and contact your next level of support.

NEXTLVL
B7xx0611 System clock problem

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

For systems managed by an HMC, use the ASM interface to reset the system clock at power on standby. For systems without an HMC, you can ignore this error.

If the error occurs a second time, contact your next level of support.

SVCDOCS
B7xx0621 System log entry only, no service action required

No service action required.

 
B7xx0A00 System log entry only, no service action required

A user request initiated an I/O tower/drawer power off. No corrective action is required.

SVCDOCS
B7xx1150 to B7xx1151 System log entry only, no service action required

No action needed unless a serviceable event was logged. If a serviceable event was logged, resolve that error.

SVCDOCS
B7xx1152 System log entry only, no service action required

No service action is required for this event.

If there is a B7001150 SRC present, and then the service processor was reset automatically to correct for the communications problem. If something more severe occurred, there will be a SRC requiring a service action logged as well.

SVCDOCS
B7xx1160 Service processor failure

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

The platform encountered an error communicating with the service processor. The platform code attempts a graceful shutdown of partitions and powers off the server after a certain time, or when the last partition indicates shutdown, whichever comes first.

SVCPROC

LICCODE
B7xx1161 System log entry only, no service action required

The platform encountered a service processor event indicating that the power status has changed. Note that this is B7xxxxxx only.

B7xx1730 Platform LIC detected an error

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

The VPD for the system is not what was expected at IPL. The IPL will not continue. Contact your next level of support.

SVCDOCS
B7xx1731 Platform LIC detected an error

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

The VPD for the system is not what was expected at IPL. Contact your next level of support.

CAPACTY
B7xx1732 Platform LIC detected an error

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

The VPD for the system is not what was expected at IPL. The VPD on a processor card is not correct. Contact your next level of support.

NEXTLVL
B7xx1733 Platform LIC detected an error

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

The VPD for the system is not what was expected at IPL. The VPD on a memory card is not correct. Contact your next level of support.

NEXTLVL
B7xx4400 There is a platform dump to collect

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

Use the operating system's interface designated to collect platform dumps.

SVCDOCS
B7xx4401 Platform LIC failure

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

The platform LIC detected an internal problem.

Contact your next level of support.

NEXTLVL
B7xx4700 to B7xx4701 Platform LIC detected an error

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

A problem occurred when initializing, reading, or using system VPD.

CAPACTY
B7xx4703 Platform LIC failure

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

A problem occurred when initializing, reading, or using system VPD.

LICCODE
B7xx4704 Platform LIC detected an error

The Capacity on Demand function is no longer available. Look for and correct errors with SRCs of the form 1xxxxxxx in the serviceable event view. If that does not correct the problem, or no errors were found, contact your next level of support.

SVCDOCS
B7xx4705 Platform LIC failure

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

A problem occurred when initializing, reading, or using system VPD.

LICCODE
B7xx4710 Platform LIC detected an error

This SRC is always of the form B700xxxx.

A communications problem with the service processor occurred.

Look for errors with SRCs of the form 1xxxxxxx or B7xx69xx in the serviceable event view. Work those errors. If no such errors are present, no service action is required.

SVCDOCS

LICCODE

CAPACTY
B7xx4712 Platform LIC detected an error

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

A problem occurred when initializing, reading, or using system VPD.

CAPACTY
B7xx4714 Platform LIC has detected a new VPD pass-through card

The new VPD pass-through card requires new activation codes. Enter the new activation codes.

SVCDOCS
B7xx4715 Platform LIC detected an error

A problem occurred when initializing, reading, or using system VPD.

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

Look for errors with SRCs of the form 1xxxxxxx in the serviceable event view. Work those errors first. If that does not correct the problem, contact your next level of support.

SVCDOCS

CAPACTY

SVCPROC
B7xx4716 User intervention required

The Capacity on Demand activation code recovery period has been started. Either obtain more capacity or allocate fewer resources.

SVCDOCS
B7xx4730 Platform LIC detected an error

This SRC is always of the form B700xxxx.

A problem occurred when configuring the logical partitions on the system. More resources were allocated than there are available for use. Either obtain more capacity or allocate fewer resources.

SVCDOCS

LPARCFG
B7xx4731 Platform LIC detected an error

This SRC is always of the form B700xxxx.

A problem occurred initializing, reading, or using system VPD. No service action is required.

CAPACTY
B7xx4733 Platform LIC failure

This SRC is always of the form B700xxxx.

A problem occurred initializing, reading, or using system VPD. No service action is required.

LICCODE
B7xx4740 Platform LIC detected an error

An incorrect activation code has been detected. Resources associated with this activation code have been disabled. Enter a valid activation code.

SVCDOCS
B7xx4741 Platform LIC detected an error

The number of allowable attempts to enter a valid activation code has been exceeded. A system IPL is required in order to retry entering a valid activation code.

SVCDOCS
B7xx4742 Platform LIC detected an error

A communications problem with the service processor occurred. No Capacity on Demand changes can be made.

Look for errors with SRCs of the form B1xxxxxx or B7xx69xx in the serviceable event view. Work those errors first. If that does not correct the problem, contact your next level of support.

SVCDOCS
B7xx4747 User intervention required

One hour remains until the On/Off Capacity on Demand request expires. All temporary resources should be removed from partitions before the request expires.

SVCDOCS
B7xx4748 User intervention required

One hour remains until the Reserve Capacity on Demand request expires. In order to reactivate temporary resources, a new Reserve Capacity on Demand enablement code is required.

SVCDOCS
B7xx4749 User intervention required

One hour remains until the Trial Customer on Demand activation expires. All temporary resources should be removed from partitions before the request expires.

SVCDOCS
B7xx4750 A Capacity on Demand change has been detected

A Reserve Capacity on Demand resource has been activated.

SVCDOCS
B7xx4780 to B7xx4783 System log entry only, no service action required

The data obtained from the system is not what was expected. The IPL will continue. Should other errors occur, contact your next level of support.

SVCDOCS
B7xx47FF System log entry only, no service action required

The Capacity on Demand History Log has been written to the error log. No service action is required.

SVCDOCS
B7xx5120 Platform LIC detected an error

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

If the system is not exhibiting problematic behavior, this error can safely be ignored. Otherwise, contact your next level of support.

NEXTLVL
B7xx5122 Platform LIC detected an error LICCODE
B7xx5190 Operating System error

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

The platform detected a problem in an Operating System. Check for errors in the partition ID specified in word 4 of the SRC. If correcting those errors does not correct the problem, or if you find no errors, contact your next level of support.

SVCDOCS
B7xx5300 Platform LIC detected a failure while partitioning resources

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

Platform partitioning code encountered an error. This SRC represents a large number of possible problems, most of which involve the platform Licensed Internal Code (LIC).

Work any error logs found in the serviceable event view. If this fails to correct the problem, or if there are no other errors, contact your next level of support.

B7xx5400 A resource has been disabled due to hardware problems

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

The platform detected a problem with a processor. The processor is not functional.

Look in the serviceable event view for a B1xxxxxx error that implicates a processor.

If the serviceable event view contains no B1xxxxxx error, or if resolving the error fails to correct the problem, contact your next level of support.

SVCDOCS
B7xx5600 to B7xx5601 Platform LIC failure

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

There was a problem initializing, reading, or using system VPD.

NEXTLVL
B7xx6900 PCI host bridge failure

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

If the serviceable event view is not available, then use the failing item list presented here for servicing this reference code.

SIIOADP

PRI_PCI

MA_BRDG

MABIP50

PIOCARD
B7xx6906 System bus error

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

SIIOADP
B7xx6907 System bus error

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

SIIOADP

LICCODE
B7xx6908 System bus error

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

PRI_PCI
B7xx6909 System bus error

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

PRI_PCI

LICCODE
B7xx6970 PCI host bridge failure

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

SIIOADP

PRI_PCI

MA_BRDG

MABIP50

PIOCARD
B7xx6971 PCI secondary bus failure

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

MABIP50

MA_BRDG

MASBUS

PIOCARD
B7xx6972 System bus error

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

MA_BRDG

PRI_PCI
B7xx6973 System bus error

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

If the first half of word 7 is not 0001, remove SVCPROC (the service processor) from the list of possible FRUs.

PIOCARD

MA_BRDG

SVCPROC

PRI_PCI

MASBUS
B7xx6974 Multi-adapter bridge configuration change or error

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

MABRCFG

PIOCARD
B7xx6980 Network Interface Controller (NIC) resource failure

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

Note: A fiber optic cleaning kit might be required for optical HSL connections.

SICNTRL

OPT_CLN
B7xx6981 High Speed Link (HSL) I/O bridge failure

If you find a B1xxxxxx SRC logged on the same tower as one of the FRUs here, and then close this problem and work the B1xxxxxx SRC. Use the unit value of the location codes to determine if the tower is the same.

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

SIIOADP
B7xx6982 High Speed Link (HSL) connection failure

Perform the RIOIP11 procedure.

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

Note: A fiber optic cleaning kit might be required for optical HSL connections.

SVCDOCS

HSL_LNK

OPT_CLN

FRPORT

TOPORT
B7xx6983 An invalid High Speed Link (HSL) configuration was detected

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

The four rightmost characters of word 4 in the reference code represent the Program Return Code (PRC), which describes the problem detected. The four leftmost digits of word 7 represent the loop number in hexadecimal format. Convert the loop number to decimal format before comparing it to loop numbers shown in serviceable event views and service tools.

To determine the problem, find the PRC in the list below.

Note: The FRU description in the serviceable event view might already contain a message that identifies the problem.
  • xxxx0008 indicates the system serial number is not set. Set the serial number on the system unit. If the problem persists contact your next level of support.
  • xxxx3201 indicates there are clustered systems on multiple HSL/RIO loops. You will need to ensure all clustered systems are on the same HSL/RIO loop.
  • xxxx3217 indicates there is a model 5791, 5792, or 5794 IO drawer on a loop with clustered systems. This is not a supported configuration.

This ends the procedure.

SIRGCFG
B7xx6984 System log entry only, no service action required

An HSL loop has switched to its alternate path. This is an informational SRC only.

Word 7 of the SRC contains the loop number in the leftmost 4 digits. The loop number is in hexadecimal format. You must convert the hexadecimal loop number into decimal format to recognize the loop number.

This SRC can be caused by a tower on the HSL loop powering off.

This SRC might also appear in a serviceable event view you are using, with a B7006982 or B7006981 logged at approximately the same time. In that case the other SRC is reporting a failure and this SRC is reporting that the alternate RIO path is now being used. Service the other SRC if present.

SVCDOCS
B7xx6985 High Speed Link (HSL) loop status message

This is a serviceable event only if this error is in a serviceable event view such as the Service Focal Point on HMC, the SAL on i5/OS, the Diagnostic Results Log on AIX or Linux, or the ASMI Error Log. If this is a serviceable event, then perform RIOIP12. Otherwise if this is NOT a serviceable event, then to determine what this SRC means use symbolic FRU SIRSTAT.

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

Note: A fiber optic cleaning kit might be required for optical HSL connections.

SVCDOCS

HSL_LNK

OPT_CLN

FRPORT

TOPORT
B7xx6986 System bus error

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

If the serviceable event view is not available, then use the failing item list presented here for servicing this reference code.

TWRCARD

PWRCBL
B7xx6987 High Speed Link (HSL) connection failure

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

If the serviceable event view is not available, then use the failing item list presented here for servicing this reference code.

HSL_LNK

OPT_CLN
B7xx6990 Service processor failure

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

If the serviceable event view is not available, then use the failing item list presented here for servicing this reference code.

SVCPROC
B7xx6991 to B7xx6992 Platform LIC failure

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

LICCODE
B7xx6993 Service processor failure

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

If the serviceable event view is not available, then use the failing item list presented here for servicing this reference code.

SVCPROC

LICCODE
B7xx6994 Service processor failure

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

If the serviceable event view is not available, then use the failing item list presented here for servicing this reference code.

SVCPROC
B7xx69E1 Host Channel Adapter

The 12X Host Channel Adapter has failed.

SVCDOCS
B7xx69E2 Platform LIC failure

A Platform Licensed Internal Code error occurred related to 12X technology. The system will continue to run with this Host Channel Adapter disabled. Perform a platform dump prior to IPLing the system. An IPL is required to recover the Host Channel Adapter.

LICCODE
B7xx69E3 System log entry only, no service action required

Part of the HCA chip failed but was not terminating. When thresholded, these errors will result in a B70069E1.

B7xx69E4 An invalid High Speed Link (HSL) configuration was detected

An error was detected in the fabric. Have the customer check for problems reported at the IBM Network Manager. This includes cases such as path migration, etc.

SVCDOCS
B7xx69E5 System log entry only, no service action required

A 12X communications error occurred. Unrecognized command from Subnet Manager. Does not require service.

B7xx69E6 System log entry only, no service action required

The cable connection to the switch is broken. Verify that the cable is connected and the switch is powered on. After repairing the problem, verify that the connection has been restored by using the IBM Network Manager. Does not require service.

B7xx69E7 System log entry only, no service action required

The cable connection to the switch has been restored. No service action required.

B7xx69E9 System log entry only, no service action required

Initial communication has occurred with the Subnet Manager. No service action required. The CEC and switch firmware are now communicating.

B7xx69EA System log entry only, no service action required

Reported when the logical switch receives a setPortInfo for the switch management port that sets a new SM LID. This indicates the point where DMA can report changes in switch port states to SM via a TRAP and also that SM has received and accepted out responses to the initial gets. This proves that there is 2-way communication. Note that this will also tell us when a subnet merge has occurred and a new SM has issued a setPortInfo with an SMLID that differs from the previous one. No service action required.

B7xx69EB User intervention required

A 12X configuration error was detected by the HCA. Verify that the configuration is correct at the HCA. The Port 1 and 2 configurations conflict.

SVCDOCS
B7xxC2AC System log entry only, no service action required

The Capacity on Demand License acceptance has completed.

No corrective action is required.

SVCDOCS
B7xxF103 Platform LIC failure

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

The platform LIC detected an internal problem.

Collect all the SRC words and the platform system dump, and then contact your next level of support.

LICCODE
B7xxF104 Operating System error

Platform LIC terminated a partition. Platform LIC terminated a partition with an unresponsive Operating System. Collect all the SRC words and the platform system dump, and then contact your next level of support.

NEXTLVL
B7xxF105 Platform LIC detected an error

Work with the FRU list in the serviceable event view if there is one; otherwise, use the FRU list documented here to determine the parts to exchange.

The platform LIC detected an internal problem.

Collect all the SRC words and the platform system dump, and then contact your next level of support.

NEXTLVL